The eValuation of Image Guidance of Stereotactic Body Radiotherapy Using Ultrasound: Assessment in Liver (VISUAL)

Worldwide, primary liver cancer is the 3rd most common cause of cancer-related death, accounting for 6% of cancer diagnoses. In the UK, the number of cases reported has more than trebled since the 1970's, with 5550 new cases in 2014 (CRUK statistics 2014). Liver transplant or surgery are the main forms of treatment offered but only less than 20% of patients can tolerate these treatments. There is a need for non-surgical therapies that would improve these patients' chances of survival. Radiotherapy has been shown to increase the likelihood of liver cancer cure. To deliver radiotherapy safely to the patient, the radiation must be delivered to the liver cancer only, avoiding normal liver tissues and other surrounding normal tissues. Because the liver moves during breathing, a liver cancer will also move during radiotherapy. To accurately target the cancer the patient can be asked to hold their breath during treatment to stop the motion. Or motion of the cancer can be monitored and the radiation beam can be moved to follow its motion. The investigators are investigating new methods to either: (a) ensure that when the patient repeats their breath hold the cancer is in the same position each time, or (b) measure the motion of the liver cancer whilst the patient breathes freely. It is not clear which is the best method and therefore are investigating both approaches. Ultrasound is a non-invasive and real-time imaging method that can easily be used to image the liver and may be able to perform both of these tasks. In this study the investigators will test ultrasound equipment, which has been specifically designed to guide radiotherapy. 26 healthy volunteers will be recruited to help evaluate the accuracy of ultrasound to measure the position of the liver in breath hold and in free breathing.

調査の概要

状態

わからない

条件

詳細な説明

PURPOSE: This observational study of healthy volunteers will test the use of a safe, non-ionising and non-invasive imaging system for the purpose of improving radiotherapy treatment of the liver. This study investigates an image guidance method which may be used to guide liver radiotherapy and enable more accurate treatment on a conventional radiotherapy machine.

RECRUITMENT: Volunteers will need to provide their National Health Service (UK) numbers and be registered on the hospital information system. Volunteers need to be aware that if they are patients at the Royal Marsden Hospital this may raise confidentiality issues. Volunteers will be made aware of this in the recruiting email and the Volunteer Information sheet.

USE OF HEALTHY VOLUNTEERS: This is an observational study, which tests the use of an ultrasound guidance system. The accuracy of the system will be evaluated by comparison of proprietary methods of liver position estimation against a manually derived ground truth derived from the images of the liver acquired in participants. It is not expected that there are any differences in the ultrasound guidance images of healthy volunteers and patients with liver cancer. Ultrasound is a non-invasive and non-ionizing imaging modality with no known side-effects or complications and therefore, safe to use in a volunteer study. Furthermore, this study requires that participants lie on a hard couch for up to 45 minutes and up to 4 times. This would be challenging for the vast majority of patients with liver cancer who are most likely to be frail due to their disease.

REVIEW OF HEALTHY VOLUNTEERS: The ultrasound guidance system provides 3D ultrasound images of the liver for providing positional information only. It is very unlikely that abnormalities will be detectable on 3D US guidance images. These images are not of diagnostic quality, being lower resolution than routine diagnostic 2D ultrasound images. Furthermore, diagnostic ultrasound of the liver often incorporates ultrasound contrast agent, which will not be used in this study. If a radiographer does observe any abnormality, this will be reported to a Consultant Radiologist and the images will be made available for review.

RISKS, BURDENS and BENEFITS: There is very little risk associated with ultrasound and the Automatic Breathing Control (ABC) device, both pieces of the equipment are CE-marked and we are not using outside of their respective intended purposes. The burden to the volunteer is (1) the time spent, (2) the uncomfortable nature of the couch (it has a hard flat surface) and (3) discomfort using the ABC device. The participant will made aware of (1), (2) and (3) by providing details in the volunteer information sheet. Participants who are uncomfortable using the ABC can opt out and still participate in the study. Participants will be able to get up from the couch and walk around to relive any discomfort at any point during the imaging sessions.

There are no benefits for the participants. It is expected that this study will be of benefit to future patients with liver cancer. To ensure there is no perceived benefit of the acquisition of ultrasound images it is stated clearly in the volunteer information sheet that images are not of diagnostic quality and that persons obtaining the images are trained in therapy guidance and not diagnostics, and that images will only be reviewed by a radiologist in the unlikely event that an abnormality is observed.

CONFLICTS OF INTEREST: There are no conflicts of interest. No study investigator will benefit financially from the outcome of this study. The manufacturer of the Clarity ultrasound system will be informed of the results and all results will be published in a peer-reviewed scientific journal.

ACCESS to DATA: The investigators wish to make anonymised image data available to other researchers on request for the purpose of medical research. This is intended to maximise the value of the data and may provide greater benefit to patients. Volunteers will be asked to consent to their anonymised data being made available to other researchers.

AIMS: This study aims to develop and evaluate the use of 3 ultrasound (3DUS) to estimate the liver position for radiotherapy guidance. This is an exploratory study, where Clarity US of the abdomen will be acquired in healthy volunteers. 3D US-sim, 3D US-guide, 3D US-monitor and 4D US-monitor will be used to meet the following study objectives:

  1. The accuracy of B-mode 3D US-guide, to estimate the position of the liver in breath-hold for verification of (1) daily set-up position (set-up US-guide) and (2) repeat breath hold relevant to radiotherapy delivery (BH 3D US-monitor), will be determined. Accuracy will be assessed by comparison of US-guide and US-monitor determined liver position with a manually determined 'gold standard' liver position.
  2. Comparison of the accuracy of power Doppler and B-mode US-guide/US-monitor for the estimation of liver position during breath hold.
  3. Assessment of the accuracy of 4D US-monitor to estimate liver motion during free breathing (FB).
  4. Comparison of liver position stability using spirometry and voluntary breath-hold (vBH) using US-monitoring.
  5. Assessment of the availability of a second or third ultrasound field of view for increasing the accuracy of US-guide based estimates of liver motion.

研究の種類

観察的

入学 (予想される)

26

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

18年歳以上 (大人、高齢者)

健康ボランティアの受け入れ

はい

受講資格のある性別

全て

サンプリング方法

非確率サンプル

調査対象母集団

Healthy adult volunteers drawn from staff at ICR and Royal Marsden Hospital

説明

Inclusion Criteria:

  • Healthy adult volunteers.

Exclusion Criteria:

  • Healthy volunteers who are unable to hold their breath for 30 seconds in exhalation.
  • Healthy volunteers who are unable to lie for extended period of time (up to 45 minutes including short breaks of a few minutes) on a hard surface (treatment couch).

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

コホートと介入

グループ/コホート
介入・治療
Group A
Volunteers will be asked to receive ultrasound imaging in repeat voluntary breath hold and during free-breathing.
Abdominal ultrasound imaging of the liver
Group B
Volunteers will be asked to receive ultrasound imaging in repeat voluntary breath hold and during free-breathing and in repeat spirometer assisted breath hold.
Abdominal ultrasound imaging of the liver

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Difference in liver position after set-up
時間枠:Within 2 months of image acquisition
The mean difference in liver position measured by US-guide and using the gold standard method, measured in millimetres in the superior-inferior (SI), anterior-posterior (AP) and left-right (LR) directions over 5 set-up sessions.
Within 2 months of image acquisition

二次結果の測定

結果測定
メジャーの説明
時間枠
Difference in liver position during repeat breath hold
時間枠:Within 2 months of image acquisition
The mean difference in liver position measured by US-guide and using the gold standard method, measured in millimetres in the superior-inferior (SI), anterior-posterior (AP) and left-right (LR) directions over 3 breath holds.
Within 2 months of image acquisition
Difference in liver position after set-up using Doppler ultrasound and US-guide
時間枠:Within 2 months of image acquisition
The mean difference in liver position measured by B-mode US-guide and using the Doppler US-guide method, measured in millimetres in the superior-inferior (SI), anterior-posterior (AP) and left-right (LR) directions over 5 set-ups.
Within 2 months of image acquisition
Liver position during free-breathing
時間枠:Within 2 months of image acquisition
The liver position measured in the SI, AP and LR directions, measured by 4D US-monitor during free breathing.
Within 2 months of image acquisition
Liver motion between fractions and repeat thresholds
時間枠:Within 2 months of image acquisition
The mean motion of the liver during voluntary breath-hold and assisted breath-hold measured using the gold standard method.
Within 2 months of image acquisition
Number of available imaging positions
時間枠:Within 2 months of image acquisition
The number of imaging positions (1 2 or 3), which may be used by 4D US-guide to accurately measure liver position during free-breathing.
Within 2 months of image acquisition

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

捜査官

  • 主任研究者:Emma J Harris, PhD、Institute of Cancer Research, United Kingdom

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (予想される)

2018年9月1日

一次修了 (予想される)

2019年8月1日

研究の完了 (予想される)

2019年12月1日

試験登録日

最初に提出

2018年6月22日

QC基準を満たした最初の提出物

2018年7月18日

最初の投稿 (実際)

2018年7月19日

学習記録の更新

投稿された最後の更新 (実際)

2018年7月24日

QC基準を満たした最後の更新が送信されました

2018年7月20日

最終確認日

2018年7月1日

詳しくは

本研究に関する用語

その他の研究ID番号

  • CCR4821

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

未定

IPD プランの説明

Anonymised data will be available on request