The eValuation of Image Guidance of Stereotactic Body Radiotherapy Using Ultrasound: Assessment in Liver (VISUAL)

Worldwide, primary liver cancer is the 3rd most common cause of cancer-related death, accounting for 6% of cancer diagnoses. In the UK, the number of cases reported has more than trebled since the 1970's, with 5550 new cases in 2014 (CRUK statistics 2014). Liver transplant or surgery are the main forms of treatment offered but only less than 20% of patients can tolerate these treatments. There is a need for non-surgical therapies that would improve these patients' chances of survival. Radiotherapy has been shown to increase the likelihood of liver cancer cure. To deliver radiotherapy safely to the patient, the radiation must be delivered to the liver cancer only, avoiding normal liver tissues and other surrounding normal tissues. Because the liver moves during breathing, a liver cancer will also move during radiotherapy. To accurately target the cancer the patient can be asked to hold their breath during treatment to stop the motion. Or motion of the cancer can be monitored and the radiation beam can be moved to follow its motion. The investigators are investigating new methods to either: (a) ensure that when the patient repeats their breath hold the cancer is in the same position each time, or (b) measure the motion of the liver cancer whilst the patient breathes freely. It is not clear which is the best method and therefore are investigating both approaches. Ultrasound is a non-invasive and real-time imaging method that can easily be used to image the liver and may be able to perform both of these tasks. In this study the investigators will test ultrasound equipment, which has been specifically designed to guide radiotherapy. 26 healthy volunteers will be recruited to help evaluate the accuracy of ultrasound to measure the position of the liver in breath hold and in free breathing.

研究概览

地位

未知

条件

详细说明

PURPOSE: This observational study of healthy volunteers will test the use of a safe, non-ionising and non-invasive imaging system for the purpose of improving radiotherapy treatment of the liver. This study investigates an image guidance method which may be used to guide liver radiotherapy and enable more accurate treatment on a conventional radiotherapy machine.

RECRUITMENT: Volunteers will need to provide their National Health Service (UK) numbers and be registered on the hospital information system. Volunteers need to be aware that if they are patients at the Royal Marsden Hospital this may raise confidentiality issues. Volunteers will be made aware of this in the recruiting email and the Volunteer Information sheet.

USE OF HEALTHY VOLUNTEERS: This is an observational study, which tests the use of an ultrasound guidance system. The accuracy of the system will be evaluated by comparison of proprietary methods of liver position estimation against a manually derived ground truth derived from the images of the liver acquired in participants. It is not expected that there are any differences in the ultrasound guidance images of healthy volunteers and patients with liver cancer. Ultrasound is a non-invasive and non-ionizing imaging modality with no known side-effects or complications and therefore, safe to use in a volunteer study. Furthermore, this study requires that participants lie on a hard couch for up to 45 minutes and up to 4 times. This would be challenging for the vast majority of patients with liver cancer who are most likely to be frail due to their disease.

REVIEW OF HEALTHY VOLUNTEERS: The ultrasound guidance system provides 3D ultrasound images of the liver for providing positional information only. It is very unlikely that abnormalities will be detectable on 3D US guidance images. These images are not of diagnostic quality, being lower resolution than routine diagnostic 2D ultrasound images. Furthermore, diagnostic ultrasound of the liver often incorporates ultrasound contrast agent, which will not be used in this study. If a radiographer does observe any abnormality, this will be reported to a Consultant Radiologist and the images will be made available for review.

RISKS, BURDENS and BENEFITS: There is very little risk associated with ultrasound and the Automatic Breathing Control (ABC) device, both pieces of the equipment are CE-marked and we are not using outside of their respective intended purposes. The burden to the volunteer is (1) the time spent, (2) the uncomfortable nature of the couch (it has a hard flat surface) and (3) discomfort using the ABC device. The participant will made aware of (1), (2) and (3) by providing details in the volunteer information sheet. Participants who are uncomfortable using the ABC can opt out and still participate in the study. Participants will be able to get up from the couch and walk around to relive any discomfort at any point during the imaging sessions.

There are no benefits for the participants. It is expected that this study will be of benefit to future patients with liver cancer. To ensure there is no perceived benefit of the acquisition of ultrasound images it is stated clearly in the volunteer information sheet that images are not of diagnostic quality and that persons obtaining the images are trained in therapy guidance and not diagnostics, and that images will only be reviewed by a radiologist in the unlikely event that an abnormality is observed.

CONFLICTS OF INTEREST: There are no conflicts of interest. No study investigator will benefit financially from the outcome of this study. The manufacturer of the Clarity ultrasound system will be informed of the results and all results will be published in a peer-reviewed scientific journal.

ACCESS to DATA: The investigators wish to make anonymised image data available to other researchers on request for the purpose of medical research. This is intended to maximise the value of the data and may provide greater benefit to patients. Volunteers will be asked to consent to their anonymised data being made available to other researchers.

AIMS: This study aims to develop and evaluate the use of 3 ultrasound (3DUS) to estimate the liver position for radiotherapy guidance. This is an exploratory study, where Clarity US of the abdomen will be acquired in healthy volunteers. 3D US-sim, 3D US-guide, 3D US-monitor and 4D US-monitor will be used to meet the following study objectives:

  1. The accuracy of B-mode 3D US-guide, to estimate the position of the liver in breath-hold for verification of (1) daily set-up position (set-up US-guide) and (2) repeat breath hold relevant to radiotherapy delivery (BH 3D US-monitor), will be determined. Accuracy will be assessed by comparison of US-guide and US-monitor determined liver position with a manually determined 'gold standard' liver position.
  2. Comparison of the accuracy of power Doppler and B-mode US-guide/US-monitor for the estimation of liver position during breath hold.
  3. Assessment of the accuracy of 4D US-monitor to estimate liver motion during free breathing (FB).
  4. Comparison of liver position stability using spirometry and voluntary breath-hold (vBH) using US-monitoring.
  5. Assessment of the availability of a second or third ultrasound field of view for increasing the accuracy of US-guide based estimates of liver motion.

研究类型

观察性的

注册 (预期的)

26

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

是的

有资格学习的性别

全部

取样方法

非概率样本

研究人群

Healthy adult volunteers drawn from staff at ICR and Royal Marsden Hospital

描述

Inclusion Criteria:

  • Healthy adult volunteers.

Exclusion Criteria:

  • Healthy volunteers who are unable to hold their breath for 30 seconds in exhalation.
  • Healthy volunteers who are unable to lie for extended period of time (up to 45 minutes including short breaks of a few minutes) on a hard surface (treatment couch).

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

队列和干预

团体/队列
干预/治疗
Group A
Volunteers will be asked to receive ultrasound imaging in repeat voluntary breath hold and during free-breathing.
Abdominal ultrasound imaging of the liver
Group B
Volunteers will be asked to receive ultrasound imaging in repeat voluntary breath hold and during free-breathing and in repeat spirometer assisted breath hold.
Abdominal ultrasound imaging of the liver

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Difference in liver position after set-up
大体时间:Within 2 months of image acquisition
The mean difference in liver position measured by US-guide and using the gold standard method, measured in millimetres in the superior-inferior (SI), anterior-posterior (AP) and left-right (LR) directions over 5 set-up sessions.
Within 2 months of image acquisition

次要结果测量

结果测量
措施说明
大体时间
Difference in liver position during repeat breath hold
大体时间:Within 2 months of image acquisition
The mean difference in liver position measured by US-guide and using the gold standard method, measured in millimetres in the superior-inferior (SI), anterior-posterior (AP) and left-right (LR) directions over 3 breath holds.
Within 2 months of image acquisition
Difference in liver position after set-up using Doppler ultrasound and US-guide
大体时间:Within 2 months of image acquisition
The mean difference in liver position measured by B-mode US-guide and using the Doppler US-guide method, measured in millimetres in the superior-inferior (SI), anterior-posterior (AP) and left-right (LR) directions over 5 set-ups.
Within 2 months of image acquisition
Liver position during free-breathing
大体时间:Within 2 months of image acquisition
The liver position measured in the SI, AP and LR directions, measured by 4D US-monitor during free breathing.
Within 2 months of image acquisition
Liver motion between fractions and repeat thresholds
大体时间:Within 2 months of image acquisition
The mean motion of the liver during voluntary breath-hold and assisted breath-hold measured using the gold standard method.
Within 2 months of image acquisition
Number of available imaging positions
大体时间:Within 2 months of image acquisition
The number of imaging positions (1 2 or 3), which may be used by 4D US-guide to accurately measure liver position during free-breathing.
Within 2 months of image acquisition

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Emma J Harris, PhD、Institute of Cancer Research, United Kingdom

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (预期的)

2018年9月1日

初级完成 (预期的)

2019年8月1日

研究完成 (预期的)

2019年12月1日

研究注册日期

首次提交

2018年6月22日

首先提交符合 QC 标准的

2018年7月18日

首次发布 (实际的)

2018年7月19日

研究记录更新

最后更新发布 (实际的)

2018年7月24日

上次提交的符合 QC 标准的更新

2018年7月20日

最后验证

2018年7月1日

更多信息

与本研究相关的术语

其他研究编号

  • CCR4821

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

未定

IPD 计划说明

Anonymised data will be available on request

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

是的

在美国制造并从美国出口的产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.