- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT03592550
The eValuation of Image Guidance of Stereotactic Body Radiotherapy Using Ultrasound: Assessment in Liver (VISUAL)
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
PURPOSE: This observational study of healthy volunteers will test the use of a safe, non-ionising and non-invasive imaging system for the purpose of improving radiotherapy treatment of the liver. This study investigates an image guidance method which may be used to guide liver radiotherapy and enable more accurate treatment on a conventional radiotherapy machine.
RECRUITMENT: Volunteers will need to provide their National Health Service (UK) numbers and be registered on the hospital information system. Volunteers need to be aware that if they are patients at the Royal Marsden Hospital this may raise confidentiality issues. Volunteers will be made aware of this in the recruiting email and the Volunteer Information sheet.
USE OF HEALTHY VOLUNTEERS: This is an observational study, which tests the use of an ultrasound guidance system. The accuracy of the system will be evaluated by comparison of proprietary methods of liver position estimation against a manually derived ground truth derived from the images of the liver acquired in participants. It is not expected that there are any differences in the ultrasound guidance images of healthy volunteers and patients with liver cancer. Ultrasound is a non-invasive and non-ionizing imaging modality with no known side-effects or complications and therefore, safe to use in a volunteer study. Furthermore, this study requires that participants lie on a hard couch for up to 45 minutes and up to 4 times. This would be challenging for the vast majority of patients with liver cancer who are most likely to be frail due to their disease.
REVIEW OF HEALTHY VOLUNTEERS: The ultrasound guidance system provides 3D ultrasound images of the liver for providing positional information only. It is very unlikely that abnormalities will be detectable on 3D US guidance images. These images are not of diagnostic quality, being lower resolution than routine diagnostic 2D ultrasound images. Furthermore, diagnostic ultrasound of the liver often incorporates ultrasound contrast agent, which will not be used in this study. If a radiographer does observe any abnormality, this will be reported to a Consultant Radiologist and the images will be made available for review.
RISKS, BURDENS and BENEFITS: There is very little risk associated with ultrasound and the Automatic Breathing Control (ABC) device, both pieces of the equipment are CE-marked and we are not using outside of their respective intended purposes. The burden to the volunteer is (1) the time spent, (2) the uncomfortable nature of the couch (it has a hard flat surface) and (3) discomfort using the ABC device. The participant will made aware of (1), (2) and (3) by providing details in the volunteer information sheet. Participants who are uncomfortable using the ABC can opt out and still participate in the study. Participants will be able to get up from the couch and walk around to relive any discomfort at any point during the imaging sessions.
There are no benefits for the participants. It is expected that this study will be of benefit to future patients with liver cancer. To ensure there is no perceived benefit of the acquisition of ultrasound images it is stated clearly in the volunteer information sheet that images are not of diagnostic quality and that persons obtaining the images are trained in therapy guidance and not diagnostics, and that images will only be reviewed by a radiologist in the unlikely event that an abnormality is observed.
CONFLICTS OF INTEREST: There are no conflicts of interest. No study investigator will benefit financially from the outcome of this study. The manufacturer of the Clarity ultrasound system will be informed of the results and all results will be published in a peer-reviewed scientific journal.
ACCESS to DATA: The investigators wish to make anonymised image data available to other researchers on request for the purpose of medical research. This is intended to maximise the value of the data and may provide greater benefit to patients. Volunteers will be asked to consent to their anonymised data being made available to other researchers.
AIMS: This study aims to develop and evaluate the use of 3 ultrasound (3DUS) to estimate the liver position for radiotherapy guidance. This is an exploratory study, where Clarity US of the abdomen will be acquired in healthy volunteers. 3D US-sim, 3D US-guide, 3D US-monitor and 4D US-monitor will be used to meet the following study objectives:
- The accuracy of B-mode 3D US-guide, to estimate the position of the liver in breath-hold for verification of (1) daily set-up position (set-up US-guide) and (2) repeat breath hold relevant to radiotherapy delivery (BH 3D US-monitor), will be determined. Accuracy will be assessed by comparison of US-guide and US-monitor determined liver position with a manually determined 'gold standard' liver position.
- Comparison of the accuracy of power Doppler and B-mode US-guide/US-monitor for the estimation of liver position during breath hold.
- Assessment of the accuracy of 4D US-monitor to estimate liver motion during free breathing (FB).
- Comparison of liver position stability using spirometry and voluntary breath-hold (vBH) using US-monitoring.
- Assessment of the availability of a second or third ultrasound field of view for increasing the accuracy of US-guide based estimates of liver motion.
Tipo di studio
Iscrizione (Anticipato)
Contatti e Sedi
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Descrizione
Inclusion Criteria:
- Healthy adult volunteers.
Exclusion Criteria:
- Healthy volunteers who are unable to hold their breath for 30 seconds in exhalation.
- Healthy volunteers who are unable to lie for extended period of time (up to 45 minutes including short breaks of a few minutes) on a hard surface (treatment couch).
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
Coorti e interventi
Gruppo / Coorte |
Intervento / Trattamento |
|---|---|
|
Group A
Volunteers will be asked to receive ultrasound imaging in repeat voluntary breath hold and during free-breathing.
|
Abdominal ultrasound imaging of the liver
|
|
Group B
Volunteers will be asked to receive ultrasound imaging in repeat voluntary breath hold and during free-breathing and in repeat spirometer assisted breath hold.
|
Abdominal ultrasound imaging of the liver
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Difference in liver position after set-up
Lasso di tempo: Within 2 months of image acquisition
|
The mean difference in liver position measured by US-guide and using the gold standard method, measured in millimetres in the superior-inferior (SI), anterior-posterior (AP) and left-right (LR) directions over 5 set-up sessions.
|
Within 2 months of image acquisition
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Difference in liver position during repeat breath hold
Lasso di tempo: Within 2 months of image acquisition
|
The mean difference in liver position measured by US-guide and using the gold standard method, measured in millimetres in the superior-inferior (SI), anterior-posterior (AP) and left-right (LR) directions over 3 breath holds.
|
Within 2 months of image acquisition
|
|
Difference in liver position after set-up using Doppler ultrasound and US-guide
Lasso di tempo: Within 2 months of image acquisition
|
The mean difference in liver position measured by B-mode US-guide and using the Doppler US-guide method, measured in millimetres in the superior-inferior (SI), anterior-posterior (AP) and left-right (LR) directions over 5 set-ups.
|
Within 2 months of image acquisition
|
|
Liver position during free-breathing
Lasso di tempo: Within 2 months of image acquisition
|
The liver position measured in the SI, AP and LR directions, measured by 4D US-monitor during free breathing.
|
Within 2 months of image acquisition
|
|
Liver motion between fractions and repeat thresholds
Lasso di tempo: Within 2 months of image acquisition
|
The mean motion of the liver during voluntary breath-hold and assisted breath-hold measured using the gold standard method.
|
Within 2 months of image acquisition
|
|
Number of available imaging positions
Lasso di tempo: Within 2 months of image acquisition
|
The number of imaging positions (1 2 or 3), which may be used by 4D US-guide to accurately measure liver position during free-breathing.
|
Within 2 months of image acquisition
|
Collaboratori e investigatori
Investigatori
- Investigatore principale: Emma J Harris, PhD, Institute of Cancer Research, United Kingdom
Studiare le date dei record
Studia le date principali
Inizio studio (Anticipato)
Completamento primario (Anticipato)
Completamento dello studio (Anticipato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- CCR4821
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Descrizione del piano IPD
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
prodotto fabbricato ed esportato dagli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .
Prove cliniche su Neoplasie del fegato
-
Medical College of WisconsinRitiratoModello alto per il punteggio MELD (end-stage Liver Disease).Stati Uniti
Prove cliniche su Ultrasound imaging
-
Jae Won ChoiCompletato
-
University of British ColumbiaSonic Incytes; Philips Health CareNon ancora reclutamentoMalattia epatica steatotica associata a disfunzione metabolicaCanada
-
Assiut UniversityNon ancora reclutamentoLassità vaginale
-
Duke UniversityPiedmont Orthopedic SocietyCompletatoLesioni della cuffia dei rotatori | Lacerazioni della cuffia dei rotatori | Protesi totale di spallaStati Uniti
-
Association Pro-arteAttivo, non reclutanteDebolezza, Muscolo | AmiotrofiaFrancia
-
The University of Texas Health Science Center at...Xprize FoundationReclutamento
-
Smart Alfa Teknoloji San. ve Tic. A.S.CompletatoImaging ad ultrasuoni delle strutture anatomicheStati Uniti
-
Aga Khan UniversityNon ancora reclutamento
-
Sarasota Memorial Health Care SystemIscrizione su invitoNodulo tiroideo | Noduli tiroideiStati Uniti
-
University of MichiganCompletato