Optimized Camera-based Patient Positioning in CT
Optimized Camera-based Patient Positioning in CT: Impact on Radiation Exposure.
調査の概要
状態
条件
詳細な説明
The positioning of the patient at the beginning of every CT examination has an major influence on the image quality and especially on the respective effective patient dose in the CT scan. If the patient position is closer to the X-ray tube, the patient dose increases significantly and if the vertical patient position is chosen too far away from the X-ray tube, the applied dose decreases, but also the image quality.
In a retrospective observational study, patients were examined on the CT scanner Somatom X.Cite and divided into two groups, one group was with intelligent camera positioning and the other with manual positioning.
The patients received their CT scan at the Institute Radiology and Nuclear Medicine at the Nuremberg North Hospital strictly according to the clinical indication and without influence of the study.
研究の種類
入学 (実際)
連絡先と場所
研究場所
-
-
Bavaria
-
Nuremberg、Bavaria、ドイツ、90419
- Institute of Radiology and Nuclear Medicine
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
サンプリング方法
調査対象母集団
説明
Inclusion Criteria:
Only patients with a clinical indication for a CT Scan
Exclusion Criteria:
renal insufficiency, manifest hyperthyroidism and pregnancy
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 観測モデル:ケースコントロール
- 時間の展望:回顧
コホートと介入
グループ/コホート |
---|
experimental group
patients positioned with 3D camera
|
control group
patients positioned by experienced radiology assistants
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
---|---|---|
Effective dose
時間枠:10 months
|
the absorbed dose to different organs of the body
|
10 months
|
協力者と研究者
スポンサー
捜査官
- スタディディレクター:Michael M. Lell, Prof. Dr.、Department of Radiology and Nuclear Medicine, Klinikum Nuernberg, Paracelsus Medical University, Germany
出版物と役立つリンク
一般刊行物
- Booij R, Budde RPJ, Dijkshoorn ML, van Straten M. Accuracy of automated patient positioning in CT using a 3D camera for body contour detection. Eur Radiol. 2019 Apr;29(4):2079-2088. doi: 10.1007/s00330-018-5745-z. Epub 2018 Oct 10.
- Kaasalainen T, Palmu K, Reijonen V, Kortesniemi M. Effect of patient centering on patient dose and image noise in chest CT. AJR Am J Roentgenol. 2014 Jul;203(1):123-30. doi: 10.2214/AJR.13.12028.
- Saltybaeva N, Schmidt B, Wimmer A, Flohr T, Alkadhi H. Precise and Automatic Patient Positioning in Computed Tomography: Avatar Modeling of the Patient Surface Using a 3-Dimensional Camera. Invest Radiol. 2018 Nov;53(11):641-646. doi: 10.1097/RLI.0000000000000482.
- Marsh RM, Silosky MS. The effects of patient positioning when interpreting CT dose metrics: A phantom study. Med Phys. 2017 Apr;44(4):1514-1524. doi: 10.1002/mp.12137. Epub 2017 Mar 17.
- Dane B, O'Donnell T, Liu S, Vega E, Mohammed S, Singh V, Kapoor A, Megibow A. Radiation dose reduction, improved isocenter accuracy and CT scan time savings with automatic patient positioning by a 3D camera. Eur J Radiol. 2021 Mar;136:109537. doi: 10.1016/j.ejrad.2021.109537. Epub 2021 Jan 12.
- Manava P, Galster M, Ammon J, Singer J, Lell MM, Rieger V. Optimized Camera-Based Patient Positioning in CT: Impact on Radiation Exposure. Invest Radiol. 2022 Aug 2. doi: 10.1097/RLI.0000000000000904. [Epub ahead of print]
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- CT_2021
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。