Optimized Camera-based Patient Positioning in CT
Optimized Camera-based Patient Positioning in CT: Impact on Radiation Exposure.
Przegląd badań
Status
Warunki
Szczegółowy opis
The positioning of the patient at the beginning of every CT examination has an major influence on the image quality and especially on the respective effective patient dose in the CT scan. If the patient position is closer to the X-ray tube, the patient dose increases significantly and if the vertical patient position is chosen too far away from the X-ray tube, the applied dose decreases, but also the image quality.
In a retrospective observational study, patients were examined on the CT scanner Somatom X.Cite and divided into two groups, one group was with intelligent camera positioning and the other with manual positioning.
The patients received their CT scan at the Institute Radiology and Nuclear Medicine at the Nuremberg North Hospital strictly according to the clinical indication and without influence of the study.
Typ studiów
Zapisy (Rzeczywisty)
Kontakty i lokalizacje
Lokalizacje studiów
-
-
Bavaria
-
Nuremberg, Bavaria, Niemcy, 90419
- Institute of Radiology and Nuclear Medicine
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Metoda próbkowania
Badana populacja
Opis
Inclusion Criteria:
Only patients with a clinical indication for a CT Scan
Exclusion Criteria:
renal insufficiency, manifest hyperthyroidism and pregnancy
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Modele obserwacyjne: Kontrola przypadków
- Perspektywy czasowe: Z mocą wsteczną
Kohorty i interwencje
Grupa / Kohorta |
|---|
|
experimental group
patients positioned with 3D camera
|
|
control group
patients positioned by experienced radiology assistants
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Effective dose
Ramy czasowe: 10 months
|
the absorbed dose to different organs of the body
|
10 months
|
Współpracownicy i badacze
Sponsor
Śledczy
- Dyrektor Studium: Michael M. Lell, Prof. Dr., Department of Radiology and Nuclear Medicine, Klinikum Nuernberg, Paracelsus Medical University, Germany
Publikacje i pomocne linki
Publikacje ogólne
- Booij R, Budde RPJ, Dijkshoorn ML, van Straten M. Accuracy of automated patient positioning in CT using a 3D camera for body contour detection. Eur Radiol. 2019 Apr;29(4):2079-2088. doi: 10.1007/s00330-018-5745-z. Epub 2018 Oct 10.
- Kaasalainen T, Palmu K, Reijonen V, Kortesniemi M. Effect of patient centering on patient dose and image noise in chest CT. AJR Am J Roentgenol. 2014 Jul;203(1):123-30. doi: 10.2214/AJR.13.12028.
- Saltybaeva N, Schmidt B, Wimmer A, Flohr T, Alkadhi H. Precise and Automatic Patient Positioning in Computed Tomography: Avatar Modeling of the Patient Surface Using a 3-Dimensional Camera. Invest Radiol. 2018 Nov;53(11):641-646. doi: 10.1097/RLI.0000000000000482.
- Marsh RM, Silosky MS. The effects of patient positioning when interpreting CT dose metrics: A phantom study. Med Phys. 2017 Apr;44(4):1514-1524. doi: 10.1002/mp.12137. Epub 2017 Mar 17.
- Dane B, O'Donnell T, Liu S, Vega E, Mohammed S, Singh V, Kapoor A, Megibow A. Radiation dose reduction, improved isocenter accuracy and CT scan time savings with automatic patient positioning by a 3D camera. Eur J Radiol. 2021 Mar;136:109537. doi: 10.1016/j.ejrad.2021.109537. Epub 2021 Jan 12.
- Manava P, Galster M, Ammon J, Singer J, Lell MM, Rieger V. Optimized Camera-Based Patient Positioning in CT: Impact on Radiation Exposure. Invest Radiol. 2022 Aug 2. doi: 10.1097/RLI.0000000000000904. [Epub ahead of print]
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Inne numery identyfikacyjne badania
- CT_2021
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .