Optimized Camera-based Patient Positioning in CT
Optimized Camera-based Patient Positioning in CT: Impact on Radiation Exposure.
Aperçu de l'étude
Statut
Les conditions
Description détaillée
The positioning of the patient at the beginning of every CT examination has an major influence on the image quality and especially on the respective effective patient dose in the CT scan. If the patient position is closer to the X-ray tube, the patient dose increases significantly and if the vertical patient position is chosen too far away from the X-ray tube, the applied dose decreases, but also the image quality.
In a retrospective observational study, patients were examined on the CT scanner Somatom X.Cite and divided into two groups, one group was with intelligent camera positioning and the other with manual positioning.
The patients received their CT scan at the Institute Radiology and Nuclear Medicine at the Nuremberg North Hospital strictly according to the clinical indication and without influence of the study.
Type d'étude
Inscription (Réel)
Contacts et emplacements
Lieux d'étude
-
-
Bavaria
-
Nuremberg, Bavaria, Allemagne, 90419
- Institute of Radiology and Nuclear Medicine
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
Méthode d'échantillonnage
Population étudiée
La description
Inclusion Criteria:
Only patients with a clinical indication for a CT Scan
Exclusion Criteria:
renal insufficiency, manifest hyperthyroidism and pregnancy
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Modèles d'observation: Cas-témoins
- Perspectives temporelles: Rétrospective
Cohortes et interventions
Groupe / Cohorte |
|---|
|
experimental group
patients positioned with 3D camera
|
|
control group
patients positioned by experienced radiology assistants
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Effective dose
Délai: 10 months
|
the absorbed dose to different organs of the body
|
10 months
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Directeur d'études: Michael M. Lell, Prof. Dr., Department of Radiology and Nuclear Medicine, Klinikum Nuernberg, Paracelsus Medical University, Germany
Publications et liens utiles
Publications générales
- Booij R, Budde RPJ, Dijkshoorn ML, van Straten M. Accuracy of automated patient positioning in CT using a 3D camera for body contour detection. Eur Radiol. 2019 Apr;29(4):2079-2088. doi: 10.1007/s00330-018-5745-z. Epub 2018 Oct 10.
- Kaasalainen T, Palmu K, Reijonen V, Kortesniemi M. Effect of patient centering on patient dose and image noise in chest CT. AJR Am J Roentgenol. 2014 Jul;203(1):123-30. doi: 10.2214/AJR.13.12028.
- Saltybaeva N, Schmidt B, Wimmer A, Flohr T, Alkadhi H. Precise and Automatic Patient Positioning in Computed Tomography: Avatar Modeling of the Patient Surface Using a 3-Dimensional Camera. Invest Radiol. 2018 Nov;53(11):641-646. doi: 10.1097/RLI.0000000000000482.
- Marsh RM, Silosky MS. The effects of patient positioning when interpreting CT dose metrics: A phantom study. Med Phys. 2017 Apr;44(4):1514-1524. doi: 10.1002/mp.12137. Epub 2017 Mar 17.
- Dane B, O'Donnell T, Liu S, Vega E, Mohammed S, Singh V, Kapoor A, Megibow A. Radiation dose reduction, improved isocenter accuracy and CT scan time savings with automatic patient positioning by a 3D camera. Eur J Radiol. 2021 Mar;136:109537. doi: 10.1016/j.ejrad.2021.109537. Epub 2021 Jan 12.
- Manava P, Galster M, Ammon J, Singer J, Lell MM, Rieger V. Optimized Camera-Based Patient Positioning in CT: Impact on Radiation Exposure. Invest Radiol. 2022 Aug 2. doi: 10.1097/RLI.0000000000000904. [Epub ahead of print]
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Autres numéros d'identification d'étude
- CT_2021
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .