Effect of CGM With Predictive Alarm on Hypoglycemia in Young Patients With T1D. (CGMHYPO)

Impact of Continuous Glucose Monitoring (CGM) With Predictive Alarm for Hypoglycemia (Guardian Connect System) on Glycemic Control and Hypoglycemia Management in a Group of Adolescents With Type 1 Diabetes Mellitus Treated With Multiple Daily Insulin Injections (MDI).

The use of continuous glucose monitoring (CGM) is becoming the new standard in glycometabolic control in patients with Type 1 Diabetes Mellitus (T1DM) even in subjects in multiple daily insulin injections (MDI). Compared to self-monitoring of blood glucose (SMBG), the CGM systems allow continuous monitoring of the glycemic trends contributing to modify the therapeutic habits of adult and pediatric patients with T1DM and allowing to better managing of critical situations such as hypoglycemia. Recently, the accuracy and reliability performance of the latest generation of CGMs using predictive alarm for hypoglycaemia and hyperglycemia has been compared to other commercially available CGM systems, showing good levels of concordance.

The use of this new technology, through the continuous monitoring of the pre-and post-prandial glucose levels and the evaluation of the glycemic trends, could influence the therapeutic habits of patients and could substantially contribute to modifying insulin therapy. Furthermore, the presence of the predictive alarm technology for hypoglycemia could lead to reduce the number of hypoglycemic episodes and to modify the way these hypoglycemic episodes are managed; moreover, the use of this technology could improve the time spent in the target glycemic range [Time in Range (TIR), 70-180 mg/dl] with possible improvement also in glycemic variability control.

調査の概要

研究の種類

介入

入学 (実際)

20

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

      • Verona、イタリア、37126
        • Pediatric Diabetes and Metabolic Disorders Unit, Surgery, Dentistry, Paediatrics and Gynaecology, University of Verona, 1 Piazzale Stefani

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

12年~17年 (子)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

説明

Inclusion Criteria:

  • T1DM for at least 12 months [assessed by positivity of at least one of the antibodies against islet cells (ICA), insulin (IAA), glutamate dehydroxylase (GADA), islet antigen 2 (IA2A), or Zinc Transporter 8 Antibodies (ZnT8)];
  • MDI therapy from at least 6 months with basal-bolus treatment (long acting insulin analog plus rapid acting insulin analogue);
  • HbA1c < 9.0%
  • normal weight (BMI <85th percentile for age and gender);
  • no other chronic diseases (thyroiditis, celiac disease, etc) or eating behavior disorders (DCA);
  • signed informed consent from parents or legal guardians and patients (<18 y).

Exclusion Criteria:

  • T1DM for less than 12 months;
  • CSII therapy
  • Previous usage of CGM with predictive alarm for hypoglycemia or hyperglycemia
  • MDI therapy from less than 6 months
  • use of regular insulin instead of rapid acting insulin analogue;
  • other chronic diseases (thyroiditis, celiac disease, etc.) or eating behavior disorders (DCA).

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:処理
  • 割り当て:ランダム化
  • 介入モデル:クロスオーバー割り当て
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
実験的:Predictive Alarm (PA)
Patients use the CGM sensor with Predictive Alarm on set at 70 mg/dl in 20 minutes for hypoglycemia and at 250 mg/dl in 20 minutes for hyperglycemia.

Patients use CGM sensor with Predictive Alarm set at 70 mg/dl in 20 minutes for hypoglycemia and at 250 mg/dl in 20 minutes for hyperglycemia.

  1. in case of alarm from the hypoglycemia predictive algorithm, the indicated treatment was 0.1g of sugar/kg of body weight;
  2. in case of alarm from the hyperglycemia predictive algorithm, the indication was to give an extra shot of rapid-acting insulin. The dose will be calculated on the basis of personal insulin sensitivity factor (ISF), considering as target a blood glucose of 120 mg/dl and 250 mg/dl as the projected blood glucose level that will be reached in 20 minutes. This could be done only if there is no active insulin on-board, after at least 3 hours from the last rapid-acting insulin injection.
アクティブコンパレータ:Alarm on Threshold (AoT)
Patients use the CGM sensor with alarms on a threshold of 70 mg/dl for hypoglycemia and 250 mg/dl for hyperglycemia.

in case of alarm of hypoglycemia, the indicated treatment was 0.3g of sugar/kg of body weight, max 15g.

in case of alarm of hyperglycemia, the indication will be to give an extra shot of rapid-acting insulin. The dose will be calculated on the basis of personal insulin sensitivity factor (ISF), considering as target a blood glucose of 120 mg/dl and 250 mg/dl as blood glucose level to correct. This could be done only if there is no active insulin on-board, after at least 3 hours from the last rapid-acting insulin injection.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Less time spent in hypoglycaemia using Predictive Alarm vs Alarm on Threshold
時間枠:2 weeks CGM data with PA vs 2 weeks CGM data with AoT
the difference in the percentage of time spent below 70 mg/dl (TBR < 70 mg/dl) between the Alarm on Threshold (AoT) and the Predictive Alarm (PA) arms after 2 weeks of treatment
2 weeks CGM data with PA vs 2 weeks CGM data with AoT

二次結果の測定

結果測定
メジャーの説明
時間枠
Better glycemic metrics using Predictive Alarm vs Alarm on Threshold
時間枠:2 weeks CGM data with PA vs 2 weeks CGM data with AoT

the difference in the percentage of time spent in 70-180 mg/dl range (TIR) between the Alarm on Threshold (AoT) and Predictive Alarm (PA) arms after 2 weeks of treatment (V2 vs V1 and V4 vs V3); the difference in the percentage of time spent above 250 mg/dl (TAR > 250 mg/dl) between the Alarm on Threshold and Predictive Alarm arms after 2 weeks of treatment (V2 vs V1 and V4 vs V3).

the difference in main glucose metrics (%TIR, %TBR, %TAR) and glucose variability measures (SD, %CV, MAG, MAGE, HBGI, LBGI, ADRR, CONGA, MODD) between Group A (PA/AoT) and Group B (AoT/PA) at the end of the treatment period (V4) vs baseline (V1)

2 weeks CGM data with PA vs 2 weeks CGM data with AoT

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

出版物と役立つリンク

研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。

一般刊行物

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2021年5月10日

一次修了 (実際)

2022年3月28日

研究の完了 (実際)

2022年6月10日

試験登録日

最初に提出

2022年10月7日

QC基準を満たした最初の提出物

2022年10月7日

最初の投稿 (実際)

2022年10月10日

学習記録の更新

投稿された最後の更新 (実際)

2022年10月10日

QC基準を満たした最後の更新が送信されました

2022年10月7日