- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT05574023
Effect of CGM With Predictive Alarm on Hypoglycemia in Young Patients With T1D. (CGMHYPO)
Impact of Continuous Glucose Monitoring (CGM) With Predictive Alarm for Hypoglycemia (Guardian Connect System) on Glycemic Control and Hypoglycemia Management in a Group of Adolescents With Type 1 Diabetes Mellitus Treated With Multiple Daily Insulin Injections (MDI).
The use of continuous glucose monitoring (CGM) is becoming the new standard in glycometabolic control in patients with Type 1 Diabetes Mellitus (T1DM) even in subjects in multiple daily insulin injections (MDI). Compared to self-monitoring of blood glucose (SMBG), the CGM systems allow continuous monitoring of the glycemic trends contributing to modify the therapeutic habits of adult and pediatric patients with T1DM and allowing to better managing of critical situations such as hypoglycemia. Recently, the accuracy and reliability performance of the latest generation of CGMs using predictive alarm for hypoglycaemia and hyperglycemia has been compared to other commercially available CGM systems, showing good levels of concordance.
The use of this new technology, through the continuous monitoring of the pre-and post-prandial glucose levels and the evaluation of the glycemic trends, could influence the therapeutic habits of patients and could substantially contribute to modifying insulin therapy. Furthermore, the presence of the predictive alarm technology for hypoglycemia could lead to reduce the number of hypoglycemic episodes and to modify the way these hypoglycemic episodes are managed; moreover, the use of this technology could improve the time spent in the target glycemic range [Time in Range (TIR), 70-180 mg/dl] with possible improvement also in glycemic variability control.
Descripción general del estudio
Estado
Condiciones
Tipo de estudio
Inscripción (Actual)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Verona, Italia, 37126
- Pediatric Diabetes and Metabolic Disorders Unit, Surgery, Dentistry, Paediatrics and Gynaecology, University of Verona, 1 Piazzale Stefani
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- T1DM for at least 12 months [assessed by positivity of at least one of the antibodies against islet cells (ICA), insulin (IAA), glutamate dehydroxylase (GADA), islet antigen 2 (IA2A), or Zinc Transporter 8 Antibodies (ZnT8)];
- MDI therapy from at least 6 months with basal-bolus treatment (long acting insulin analog plus rapid acting insulin analogue);
- HbA1c < 9.0%
- normal weight (BMI <85th percentile for age and gender);
- no other chronic diseases (thyroiditis, celiac disease, etc) or eating behavior disorders (DCA);
- signed informed consent from parents or legal guardians and patients (<18 y).
Exclusion Criteria:
- T1DM for less than 12 months;
- CSII therapy
- Previous usage of CGM with predictive alarm for hypoglycemia or hyperglycemia
- MDI therapy from less than 6 months
- use of regular insulin instead of rapid acting insulin analogue;
- other chronic diseases (thyroiditis, celiac disease, etc.) or eating behavior disorders (DCA).
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación cruzada
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
---|---|
Experimental: Predictive Alarm (PA)
Patients use the CGM sensor with Predictive Alarm on set at 70 mg/dl in 20 minutes for hypoglycemia and at 250 mg/dl in 20 minutes for hyperglycemia.
|
Patients use CGM sensor with Predictive Alarm set at 70 mg/dl in 20 minutes for hypoglycemia and at 250 mg/dl in 20 minutes for hyperglycemia.
|
Comparador activo: Alarm on Threshold (AoT)
Patients use the CGM sensor with alarms on a threshold of 70 mg/dl for hypoglycemia and 250 mg/dl for hyperglycemia.
|
in case of alarm of hypoglycemia, the indicated treatment was 0.3g of sugar/kg of body weight, max 15g. in case of alarm of hyperglycemia, the indication will be to give an extra shot of rapid-acting insulin. The dose will be calculated on the basis of personal insulin sensitivity factor (ISF), considering as target a blood glucose of 120 mg/dl and 250 mg/dl as blood glucose level to correct. This could be done only if there is no active insulin on-board, after at least 3 hours from the last rapid-acting insulin injection. |
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
---|---|---|
Less time spent in hypoglycaemia using Predictive Alarm vs Alarm on Threshold
Periodo de tiempo: 2 weeks CGM data with PA vs 2 weeks CGM data with AoT
|
the difference in the percentage of time spent below 70 mg/dl (TBR < 70 mg/dl) between the Alarm on Threshold (AoT) and the Predictive Alarm (PA) arms after 2 weeks of treatment
|
2 weeks CGM data with PA vs 2 weeks CGM data with AoT
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
---|---|---|
Better glycemic metrics using Predictive Alarm vs Alarm on Threshold
Periodo de tiempo: 2 weeks CGM data with PA vs 2 weeks CGM data with AoT
|
the difference in the percentage of time spent in 70-180 mg/dl range (TIR) between the Alarm on Threshold (AoT) and Predictive Alarm (PA) arms after 2 weeks of treatment (V2 vs V1 and V4 vs V3); the difference in the percentage of time spent above 250 mg/dl (TAR > 250 mg/dl) between the Alarm on Threshold and Predictive Alarm arms after 2 weeks of treatment (V2 vs V1 and V4 vs V3). the difference in main glucose metrics (%TIR, %TBR, %TAR) and glucose variability measures (SD, %CV, MAG, MAGE, HBGI, LBGI, ADRR, CONGA, MODD) between Group A (PA/AoT) and Group B (AoT/PA) at the end of the treatment period (V4) vs baseline (V1) |
2 weeks CGM data with PA vs 2 weeks CGM data with AoT
|
Colaboradores e Investigadores
Patrocinador
Publicaciones y enlaces útiles
Publicaciones Generales
- Rodbard D. Continuous Glucose Monitoring: A Review of Recent Studies Demonstrating Improved Glycemic Outcomes. Diabetes Technol Ther. 2017 Jun;19(S3):S25-S37. doi: 10.1089/dia.2017.0035.
- Taleb N, Emami A, Suppere C, Messier V, Legault L, Chiasson JL, Rabasa-Lhoret R, Haidar A. Comparison of Two Continuous Glucose Monitoring Systems, Dexcom G4 Platinum and Medtronic Paradigm Veo Enlite System, at Rest and During Exercise. Diabetes Technol Ther. 2016 Sep;18(9):561-7. doi: 10.1089/dia.2015.0394. Epub 2016 Jun 29.
- Christiansen MP, Garg SK, Brazg R, Bode BW, Bailey TS, Slover RH, Sullivan A, Huang S, Shin J, Lee SW, Kaufman FR. Accuracy of a Fourth-Generation Subcutaneous Continuous Glucose Sensor. Diabetes Technol Ther. 2017 Aug;19(8):446-456. doi: 10.1089/dia.2017.0087. Epub 2017 Jul 12.
- Slover RH, Tryggestad JB, DiMeglio LA, Fox LA, Bode BW, Bailey TS, Brazg R, Christiansen MP, Sherr JL, Tsalikian E, Kaiserman KB, Sullivan A, Huang S, Shin J, Lee SW, Kaufman FR. Accuracy of a Fourth-Generation Continuous Glucose Monitoring System in Children and Adolescents with Type 1 Diabetes. Diabetes Technol Ther. 2018 Sep;20(9):576-584. doi: 10.1089/dia.2018.0109. Epub 2018 Jul 31.
- Sherr JL, Tauschmann M, Battelino T, de Bock M, Forlenza G, Roman R, Hood KK, Maahs DM. ISPAD Clinical Practice Consensus Guidelines 2018: Diabetes technologies. Pediatr Diabetes. 2018 Oct;19 Suppl 27:302-325. doi: 10.1111/pedi.12731. No abstract available.
- van Beers CA, DeVries JH, Kleijer SJ, Smits MM, Geelhoed-Duijvestijn PH, Kramer MH, Diamant M, Snoek FJ, Serne EH. Continuous glucose monitoring for patients with type 1 diabetes and impaired awareness of hypoglycaemia (IN CONTROL): a randomised, open-label, crossover trial. Lancet Diabetes Endocrinol. 2016 Nov;4(11):893-902. doi: 10.1016/S2213-8587(16)30193-0. Epub 2016 Sep 15.
- Welsh JB, Gao P, Derdzinski M, Puhr S, Johnson TK, Walker TC, Graham C. Accuracy, Utilization, and Effectiveness Comparisons of Different Continuous Glucose Monitoring Systems. Diabetes Technol Ther. 2019 Mar;21(3):128-132. doi: 10.1089/dia.2018.0374. Epub 2019 Jan 25.
- Danne T, Nimri R, Battelino T, Bergenstal RM, Close KL, DeVries JH, Garg S, Heinemann L, Hirsch I, Amiel SA, Beck R, Bosi E, Buckingham B, Cobelli C, Dassau E, Doyle FJ 3rd, Heller S, Hovorka R, Jia W, Jones T, Kordonouri O, Kovatchev B, Kowalski A, Laffel L, Maahs D, Murphy HR, Norgaard K, Parkin CG, Renard E, Saboo B, Scharf M, Tamborlane WV, Weinzimer SA, Phillip M. International Consensus on Use of Continuous Glucose Monitoring. Diabetes Care. 2017 Dec;40(12):1631-1640. doi: 10.2337/dc17-1600.
- Wright LA, Hirsch IB. Metrics Beyond Hemoglobin A1C in Diabetes Management: Time in Range, Hypoglycemia, and Other Parameters. Diabetes Technol Ther. 2017 May;19(S2):S16-S26. doi: 10.1089/dia.2017.0029.
- Stone MP, Agrawal P, Chen X, Liu M, Shin J, Cordero TL, Kaufman FR. Retrospective Analysis of 3-Month Real-World Glucose Data After the MiniMed 670G System Commercial Launch. Diabetes Technol Ther. 2018 Oct;20(10):689-692. doi: 10.1089/dia.2018.0202. Epub 2018 Aug 30.
- Leelarathna L, Thabit H, Wilinska ME, Bally L, Mader JK, Pieber TR, Benesch C, Arnolds S, Johnson T, Heinemann L, Hermanns N, Evans ML, Hovorka R. Evaluating Glucose Control With a Novel Composite Continuous Glucose Monitoring Index. J Diabetes Sci Technol. 2020 Mar;14(2):277-283. doi: 10.1177/1932296819838525. Epub 2019 Mar 31.
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- 3142CESC
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .
Ensayos clínicos sobre Diabetes tipo 1
-
Oxford Brookes UniversityUniversity of OxfordTerminadoActividad física | Salud Mental Bienestar 1 | Función Cognitiva 1, Social | Academic Attainment | Fitness TestingReino Unido
-
Merck Sharp & Dohme LLCReclutamientoCáncer de pulmón de células no pequeñas | Tumores sólidos | Muerte celular programada-1 (PD1, PD-1) | Ligando 1 de muerte celular programada 1 (PDL1, PD-L1) | Ligando 2 de muerte celular programada 1 (PDL2, PD-L2)Japón
-
Rambam Health Care CampusIsrael Science FoundationTerminado
-
Alvotech Swiss AGTerminado
-
PfizerTerminado
-
SanionaTerminado
-
Calliditas Therapeutics ABEurofins Optimed; York Bioanalytical SolutionTerminado
-
Calliditas Therapeutics ABTerminado
-
JKT Biopharma Co., Ltd.Reclutamiento
-
Graviton Bioscience CorporationTerminado