Effect of CGM With Predictive Alarm on Hypoglycemia in Young Patients With T1D. (CGMHYPO)

Impact of Continuous Glucose Monitoring (CGM) With Predictive Alarm for Hypoglycemia (Guardian Connect System) on Glycemic Control and Hypoglycemia Management in a Group of Adolescents With Type 1 Diabetes Mellitus Treated With Multiple Daily Insulin Injections (MDI).

The use of continuous glucose monitoring (CGM) is becoming the new standard in glycometabolic control in patients with Type 1 Diabetes Mellitus (T1DM) even in subjects in multiple daily insulin injections (MDI). Compared to self-monitoring of blood glucose (SMBG), the CGM systems allow continuous monitoring of the glycemic trends contributing to modify the therapeutic habits of adult and pediatric patients with T1DM and allowing to better managing of critical situations such as hypoglycemia. Recently, the accuracy and reliability performance of the latest generation of CGMs using predictive alarm for hypoglycaemia and hyperglycemia has been compared to other commercially available CGM systems, showing good levels of concordance.

The use of this new technology, through the continuous monitoring of the pre-and post-prandial glucose levels and the evaluation of the glycemic trends, could influence the therapeutic habits of patients and could substantially contribute to modifying insulin therapy. Furthermore, the presence of the predictive alarm technology for hypoglycemia could lead to reduce the number of hypoglycemic episodes and to modify the way these hypoglycemic episodes are managed; moreover, the use of this technology could improve the time spent in the target glycemic range [Time in Range (TIR), 70-180 mg/dl] with possible improvement also in glycemic variability control.

Study Overview

Study Type

Interventional

Enrollment (Actual)

20

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Verona, Italy, 37126
        • Pediatric Diabetes and Metabolic Disorders Unit, Surgery, Dentistry, Paediatrics and Gynaecology, University of Verona, 1 Piazzale Stefani

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

12 years to 17 years (Child)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • T1DM for at least 12 months [assessed by positivity of at least one of the antibodies against islet cells (ICA), insulin (IAA), glutamate dehydroxylase (GADA), islet antigen 2 (IA2A), or Zinc Transporter 8 Antibodies (ZnT8)];
  • MDI therapy from at least 6 months with basal-bolus treatment (long acting insulin analog plus rapid acting insulin analogue);
  • HbA1c < 9.0%
  • normal weight (BMI <85th percentile for age and gender);
  • no other chronic diseases (thyroiditis, celiac disease, etc) or eating behavior disorders (DCA);
  • signed informed consent from parents or legal guardians and patients (<18 y).

Exclusion Criteria:

  • T1DM for less than 12 months;
  • CSII therapy
  • Previous usage of CGM with predictive alarm for hypoglycemia or hyperglycemia
  • MDI therapy from less than 6 months
  • use of regular insulin instead of rapid acting insulin analogue;
  • other chronic diseases (thyroiditis, celiac disease, etc.) or eating behavior disorders (DCA).

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Randomized
  • Interventional Model: Crossover Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Predictive Alarm (PA)
Patients use the CGM sensor with Predictive Alarm on set at 70 mg/dl in 20 minutes for hypoglycemia and at 250 mg/dl in 20 minutes for hyperglycemia.

Patients use CGM sensor with Predictive Alarm set at 70 mg/dl in 20 minutes for hypoglycemia and at 250 mg/dl in 20 minutes for hyperglycemia.

  1. in case of alarm from the hypoglycemia predictive algorithm, the indicated treatment was 0.1g of sugar/kg of body weight;
  2. in case of alarm from the hyperglycemia predictive algorithm, the indication was to give an extra shot of rapid-acting insulin. The dose will be calculated on the basis of personal insulin sensitivity factor (ISF), considering as target a blood glucose of 120 mg/dl and 250 mg/dl as the projected blood glucose level that will be reached in 20 minutes. This could be done only if there is no active insulin on-board, after at least 3 hours from the last rapid-acting insulin injection.
Active Comparator: Alarm on Threshold (AoT)
Patients use the CGM sensor with alarms on a threshold of 70 mg/dl for hypoglycemia and 250 mg/dl for hyperglycemia.

in case of alarm of hypoglycemia, the indicated treatment was 0.3g of sugar/kg of body weight, max 15g.

in case of alarm of hyperglycemia, the indication will be to give an extra shot of rapid-acting insulin. The dose will be calculated on the basis of personal insulin sensitivity factor (ISF), considering as target a blood glucose of 120 mg/dl and 250 mg/dl as blood glucose level to correct. This could be done only if there is no active insulin on-board, after at least 3 hours from the last rapid-acting insulin injection.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Less time spent in hypoglycaemia using Predictive Alarm vs Alarm on Threshold
Time Frame: 2 weeks CGM data with PA vs 2 weeks CGM data with AoT
the difference in the percentage of time spent below 70 mg/dl (TBR < 70 mg/dl) between the Alarm on Threshold (AoT) and the Predictive Alarm (PA) arms after 2 weeks of treatment
2 weeks CGM data with PA vs 2 weeks CGM data with AoT

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Better glycemic metrics using Predictive Alarm vs Alarm on Threshold
Time Frame: 2 weeks CGM data with PA vs 2 weeks CGM data with AoT

the difference in the percentage of time spent in 70-180 mg/dl range (TIR) between the Alarm on Threshold (AoT) and Predictive Alarm (PA) arms after 2 weeks of treatment (V2 vs V1 and V4 vs V3); the difference in the percentage of time spent above 250 mg/dl (TAR > 250 mg/dl) between the Alarm on Threshold and Predictive Alarm arms after 2 weeks of treatment (V2 vs V1 and V4 vs V3).

the difference in main glucose metrics (%TIR, %TBR, %TAR) and glucose variability measures (SD, %CV, MAG, MAGE, HBGI, LBGI, ADRR, CONGA, MODD) between Group A (PA/AoT) and Group B (AoT/PA) at the end of the treatment period (V4) vs baseline (V1)

2 weeks CGM data with PA vs 2 weeks CGM data with AoT

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

General Publications

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

May 10, 2021

Primary Completion (Actual)

March 28, 2022

Study Completion (Actual)

June 10, 2022

Study Registration Dates

First Submitted

October 7, 2022

First Submitted That Met QC Criteria

October 7, 2022

First Posted (Actual)

October 10, 2022

Study Record Updates

Last Update Posted (Actual)

October 10, 2022

Last Update Submitted That Met QC Criteria

October 7, 2022

Last Verified

July 1, 2022

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Type 1 Diabetes

Clinical Trials on Use of Predictive Alarm for hypoglycaemia or hyperglycaemia