- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT05574023
Effect of CGM With Predictive Alarm on Hypoglycemia in Young Patients With T1D. (CGMHYPO)
Impact of Continuous Glucose Monitoring (CGM) With Predictive Alarm for Hypoglycemia (Guardian Connect System) on Glycemic Control and Hypoglycemia Management in a Group of Adolescents With Type 1 Diabetes Mellitus Treated With Multiple Daily Insulin Injections (MDI).
The use of continuous glucose monitoring (CGM) is becoming the new standard in glycometabolic control in patients with Type 1 Diabetes Mellitus (T1DM) even in subjects in multiple daily insulin injections (MDI). Compared to self-monitoring of blood glucose (SMBG), the CGM systems allow continuous monitoring of the glycemic trends contributing to modify the therapeutic habits of adult and pediatric patients with T1DM and allowing to better managing of critical situations such as hypoglycemia. Recently, the accuracy and reliability performance of the latest generation of CGMs using predictive alarm for hypoglycaemia and hyperglycemia has been compared to other commercially available CGM systems, showing good levels of concordance.
The use of this new technology, through the continuous monitoring of the pre-and post-prandial glucose levels and the evaluation of the glycemic trends, could influence the therapeutic habits of patients and could substantially contribute to modifying insulin therapy. Furthermore, the presence of the predictive alarm technology for hypoglycemia could lead to reduce the number of hypoglycemic episodes and to modify the way these hypoglycemic episodes are managed; moreover, the use of this technology could improve the time spent in the target glycemic range [Time in Range (TIR), 70-180 mg/dl] with possible improvement also in glycemic variability control.
Study Overview
Status
Conditions
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Verona, Italy, 37126
- Pediatric Diabetes and Metabolic Disorders Unit, Surgery, Dentistry, Paediatrics and Gynaecology, University of Verona, 1 Piazzale Stefani
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- T1DM for at least 12 months [assessed by positivity of at least one of the antibodies against islet cells (ICA), insulin (IAA), glutamate dehydroxylase (GADA), islet antigen 2 (IA2A), or Zinc Transporter 8 Antibodies (ZnT8)];
- MDI therapy from at least 6 months with basal-bolus treatment (long acting insulin analog plus rapid acting insulin analogue);
- HbA1c < 9.0%
- normal weight (BMI <85th percentile for age and gender);
- no other chronic diseases (thyroiditis, celiac disease, etc) or eating behavior disorders (DCA);
- signed informed consent from parents or legal guardians and patients (<18 y).
Exclusion Criteria:
- T1DM for less than 12 months;
- CSII therapy
- Previous usage of CGM with predictive alarm for hypoglycemia or hyperglycemia
- MDI therapy from less than 6 months
- use of regular insulin instead of rapid acting insulin analogue;
- other chronic diseases (thyroiditis, celiac disease, etc.) or eating behavior disorders (DCA).
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Crossover Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: Predictive Alarm (PA)
Patients use the CGM sensor with Predictive Alarm on set at 70 mg/dl in 20 minutes for hypoglycemia and at 250 mg/dl in 20 minutes for hyperglycemia.
|
Patients use CGM sensor with Predictive Alarm set at 70 mg/dl in 20 minutes for hypoglycemia and at 250 mg/dl in 20 minutes for hyperglycemia.
|
|
Active Comparator: Alarm on Threshold (AoT)
Patients use the CGM sensor with alarms on a threshold of 70 mg/dl for hypoglycemia and 250 mg/dl for hyperglycemia.
|
in case of alarm of hypoglycemia, the indicated treatment was 0.3g of sugar/kg of body weight, max 15g. in case of alarm of hyperglycemia, the indication will be to give an extra shot of rapid-acting insulin. The dose will be calculated on the basis of personal insulin sensitivity factor (ISF), considering as target a blood glucose of 120 mg/dl and 250 mg/dl as blood glucose level to correct. This could be done only if there is no active insulin on-board, after at least 3 hours from the last rapid-acting insulin injection. |
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Less time spent in hypoglycaemia using Predictive Alarm vs Alarm on Threshold
Time Frame: 2 weeks CGM data with PA vs 2 weeks CGM data with AoT
|
the difference in the percentage of time spent below 70 mg/dl (TBR < 70 mg/dl) between the Alarm on Threshold (AoT) and the Predictive Alarm (PA) arms after 2 weeks of treatment
|
2 weeks CGM data with PA vs 2 weeks CGM data with AoT
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Better glycemic metrics using Predictive Alarm vs Alarm on Threshold
Time Frame: 2 weeks CGM data with PA vs 2 weeks CGM data with AoT
|
the difference in the percentage of time spent in 70-180 mg/dl range (TIR) between the Alarm on Threshold (AoT) and Predictive Alarm (PA) arms after 2 weeks of treatment (V2 vs V1 and V4 vs V3); the difference in the percentage of time spent above 250 mg/dl (TAR > 250 mg/dl) between the Alarm on Threshold and Predictive Alarm arms after 2 weeks of treatment (V2 vs V1 and V4 vs V3). the difference in main glucose metrics (%TIR, %TBR, %TAR) and glucose variability measures (SD, %CV, MAG, MAGE, HBGI, LBGI, ADRR, CONGA, MODD) between Group A (PA/AoT) and Group B (AoT/PA) at the end of the treatment period (V4) vs baseline (V1) |
2 weeks CGM data with PA vs 2 weeks CGM data with AoT
|
Collaborators and Investigators
Publications and helpful links
General Publications
- Rodbard D. Continuous Glucose Monitoring: A Review of Recent Studies Demonstrating Improved Glycemic Outcomes. Diabetes Technol Ther. 2017 Jun;19(S3):S25-S37. doi: 10.1089/dia.2017.0035.
- Taleb N, Emami A, Suppere C, Messier V, Legault L, Chiasson JL, Rabasa-Lhoret R, Haidar A. Comparison of Two Continuous Glucose Monitoring Systems, Dexcom G4 Platinum and Medtronic Paradigm Veo Enlite System, at Rest and During Exercise. Diabetes Technol Ther. 2016 Sep;18(9):561-7. doi: 10.1089/dia.2015.0394. Epub 2016 Jun 29.
- Christiansen MP, Garg SK, Brazg R, Bode BW, Bailey TS, Slover RH, Sullivan A, Huang S, Shin J, Lee SW, Kaufman FR. Accuracy of a Fourth-Generation Subcutaneous Continuous Glucose Sensor. Diabetes Technol Ther. 2017 Aug;19(8):446-456. doi: 10.1089/dia.2017.0087. Epub 2017 Jul 12.
- Slover RH, Tryggestad JB, DiMeglio LA, Fox LA, Bode BW, Bailey TS, Brazg R, Christiansen MP, Sherr JL, Tsalikian E, Kaiserman KB, Sullivan A, Huang S, Shin J, Lee SW, Kaufman FR. Accuracy of a Fourth-Generation Continuous Glucose Monitoring System in Children and Adolescents with Type 1 Diabetes. Diabetes Technol Ther. 2018 Sep;20(9):576-584. doi: 10.1089/dia.2018.0109. Epub 2018 Jul 31.
- Sherr JL, Tauschmann M, Battelino T, de Bock M, Forlenza G, Roman R, Hood KK, Maahs DM. ISPAD Clinical Practice Consensus Guidelines 2018: Diabetes technologies. Pediatr Diabetes. 2018 Oct;19 Suppl 27:302-325. doi: 10.1111/pedi.12731. No abstract available.
- van Beers CA, DeVries JH, Kleijer SJ, Smits MM, Geelhoed-Duijvestijn PH, Kramer MH, Diamant M, Snoek FJ, Serne EH. Continuous glucose monitoring for patients with type 1 diabetes and impaired awareness of hypoglycaemia (IN CONTROL): a randomised, open-label, crossover trial. Lancet Diabetes Endocrinol. 2016 Nov;4(11):893-902. doi: 10.1016/S2213-8587(16)30193-0. Epub 2016 Sep 15.
- Welsh JB, Gao P, Derdzinski M, Puhr S, Johnson TK, Walker TC, Graham C. Accuracy, Utilization, and Effectiveness Comparisons of Different Continuous Glucose Monitoring Systems. Diabetes Technol Ther. 2019 Mar;21(3):128-132. doi: 10.1089/dia.2018.0374. Epub 2019 Jan 25.
- Danne T, Nimri R, Battelino T, Bergenstal RM, Close KL, DeVries JH, Garg S, Heinemann L, Hirsch I, Amiel SA, Beck R, Bosi E, Buckingham B, Cobelli C, Dassau E, Doyle FJ 3rd, Heller S, Hovorka R, Jia W, Jones T, Kordonouri O, Kovatchev B, Kowalski A, Laffel L, Maahs D, Murphy HR, Norgaard K, Parkin CG, Renard E, Saboo B, Scharf M, Tamborlane WV, Weinzimer SA, Phillip M. International Consensus on Use of Continuous Glucose Monitoring. Diabetes Care. 2017 Dec;40(12):1631-1640. doi: 10.2337/dc17-1600.
- Wright LA, Hirsch IB. Metrics Beyond Hemoglobin A1C in Diabetes Management: Time in Range, Hypoglycemia, and Other Parameters. Diabetes Technol Ther. 2017 May;19(S2):S16-S26. doi: 10.1089/dia.2017.0029.
- Stone MP, Agrawal P, Chen X, Liu M, Shin J, Cordero TL, Kaufman FR. Retrospective Analysis of 3-Month Real-World Glucose Data After the MiniMed 670G System Commercial Launch. Diabetes Technol Ther. 2018 Oct;20(10):689-692. doi: 10.1089/dia.2018.0202. Epub 2018 Aug 30.
- Leelarathna L, Thabit H, Wilinska ME, Bally L, Mader JK, Pieber TR, Benesch C, Arnolds S, Johnson T, Heinemann L, Hermanns N, Evans ML, Hovorka R. Evaluating Glucose Control With a Novel Composite Continuous Glucose Monitoring Index. J Diabetes Sci Technol. 2020 Mar;14(2):277-283. doi: 10.1177/1932296819838525. Epub 2019 Mar 31.
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- 3142CESC
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Type 1 Diabetes
-
COUR Pharmaceutical Development Company, Inc.RecruitingType 1 Diabetes | Type 1 Diabetes Mellitus | T1DM | T1D | Type 1 Diabetes in Adolescence | Type 1 Diabetes in Children | Type 1 Diabetes Patients | Type 1 Diabetes Mellitis | T1DM - Type 1 Diabetes Mellitus | Type 1 Diabetes (Juvenile Onset)United States
-
Lund UniversityEnrolling by invitationType 1 Diabetes Mellitus | Stage 2 Type 1 Diabetes | Stage 1 Type 1 Diabetes | Stage 3 Type 1 DiabetesSweden
-
Immunocore LtdNot yet recruitingType 1 Diabetes | Diabetes Type 1 | Type 1 Diabetes (T1D)
-
Sultan Qaboos UniversityUniversity of Mosul; University of Child Health Sciences and Children's Hospital...Not yet recruitingType 1 Diabetes Mellitus | T1DM | Type 1 Diabetes Mellitus (T1DM) | T1DM - Type 1 Diabetes Mellitus
-
GentiBio, IncRecruitingType 1 Diabetes Mellitus | Type 1 Diabetes (T1D)United States
-
Stanford UniversityUniversity College Dublin; The Leona M. and Harry B. Helmsley Charitable TrustNot yet recruitingType 1 Diabetes (T1D) | Type 1 Diabetes Mellitus (T1DM) | Exercise Physiology | Type 1 Diabetes MellitisUnited States
-
Dasman Diabetes InstituteRecruitingType 1 Diabetes (T1D) | Type 1 Diabetes Mellitus (T1DM)Kuwait
-
Superior UniversityActive, not recruitingType 2 Diabetes Mellitus 1Pakistan
-
Poznan University of Medical SciencesUnknownDiabetes Mellitus Type 1 | Remission of Type 1 Diabetes | Chronic Complications of DiabetesPoland
-
Insulet CorporationNot yet recruitingType 1 Diabetes | Type 1 Diabetes Mellitus | Diabetes (DM)New Zealand
Clinical Trials on Use of Predictive Alarm for hypoglycaemia or hyperglycaemia
-
Dr. med. Karsten SchenkeAsklepios proresearchRecruitingCoronary Artery Disease | Coronary AngiographyGermany
-
University of Colorado, BoulderUniversity of Colorado, DenverCompletedObesity | Type 2 Diabetes | Cannabis Use | Insulin SensitivityUnited States
-
Nicolas BabaultRoquette FrèresCompleted
-
Karolinska InstitutetCompletedSubstance Use Disorders (SUD)Sweden
-
Liverpool University Hospitals NHS Foundation TrustKidney Research United KingdomRecruitingFrailty | Kidney Transplant Rejection | Renal Transplant | Diagnosis | Kidney Transplant; Complications | Kidney Transplant | Renal Transplant Failure | Transplant DysfunctionUnited Kingdom
-
University of Southern CaliforniaNorthwestern University; National Institute on Aging (NIA); AltaMed Health Services...CompletedOpioid Abuse, UnspecifiedUnited States
-
Azienda USL ModenaCompleted
-
China Medical University HospitalCompleted
-
Brigham and Women's HospitalCompletedDiabetes Mellitus, Type 2United States
-
HIV Prevention Trials NetworkNational Institute of Allergy and Infectious Diseases (NIAID); Division of...CompletedHIV Infection | Sexually Transmitted Infections | Pre-exposure Prophylaxis | Systems NavigationMalawi