Distensibility Index of Inferior Vena Cava in Assessing Fluid Responsiveness: The Impact of Spontaneous Respiratory Effort
2026年6月8日 更新者:Jingyuan,Xu
This study explored how inspiratory effort affects the accuracy of the distensibility index of inferior vena cava (dIVC) in assessing fluid responsiveness (FR).This prospective observational study was conducted in an intensive care unit of a university hospital and included shock patients receiving ventilation with spontaneous breathing activity.
Hemodynamic parameters were collected before and after fluid challenge by the pulse indicator continuous cardiac output.
dIVC was calculated by ultrasound, and respiratory effort was assessed using airway occlusion pressure (P0.1) and end-expiratory occlusion pressure (Pocc) before fluid administration.
Responders were defined by a ≥10% increase in cardiac output (CO) after 250 mL saline infused in 10 minutes.
The dIVC > 18% was considered indicative of FR.
Predictive performance was evaluated using area under receiver operating characteristic curves (AUROC), stratified by P0.1 and Pocc.
調査の概要
状態
完了
条件
研究の種類
観察的
入学 (実際)
50
連絡先と場所
このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。
研究場所
-
-
Jiangsu
-
Nanjing、Jiangsu、中国
- Zhongda Hospital
-
-
参加基準
研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。
適格基準
就学可能な年齢
- 大人
- 高齢者
健康ボランティアの受け入れ
いいえ
サンプリング方法
確率サンプル
調査対象母集団
This prospective observational study was conducted in an intensive care unit of a university hospital and included shock patients receiving ventilation with spontaneous breathing activity
説明
Inclusion Criteria:
- defined as shock who has the presence of systolic blood pressure (SBP) ≤ 90 or a > 40 mmHg decline of SBP in patients known to be hypertensive or mean arterial pressure (MAP) ≤ 70 mmHg or requiring vasopressors to maintain SBP > 90 mmHg or MAP > 70 mmHg, along with signs of hypoperfusion (urinary flow < 0.5 ml/kg/min for > 2 h, or presence of skin mottling or blood lactate concentration ≥ 2.0 mmol/L);
- received mechanical ventilation;
- had the Pulse Indicator Continuous Cardiac Output (PiCCO) catheter for hemodynamic monitoring;
- had the sign of fluid administration which include: (a) MAP < 65 mmHg and/or SBP < 90 mmHg; (b) the need for vasopressors; (c) urinary flow < 0.5 ml/kg/min for >2 h; (d) tachycardia; (e) lactic acidosis; or (f) delayed capillary refilling.
Exclusion Criteria:
- were pregnant;
- were younger than 18 years of age;
- could not have spontaneous respiratory drive or effort measured;
- had intra-abdominal pressure ≥ 16 cmH₂O [15];
- had conditions affecting dIVC measurement, such as ECMO cannulation;
- had factors precluding clear ultrasound imaging;
- defined as right ventricular dysfunction who has (a) tricuspid annular plane systolic excursion < 16 mm; (b) moderate or greater tricuspid regurgitation; (c) moderate or greater pulmonary artery hypertension[16];
- expected to die within 24 hours;
- had family members of the patient declined enrollment.
研究計画
このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。
研究はどのように設計されていますか?
デザインの詳細
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
時間枠 |
|---|---|
|
inspiratory effort affects the accuracy of the distensibility index of inferior vena cava in assessing fluid responsiveness
時間枠:immediate
|
immediate
|
協力者と研究者
ここでは、この調査に関係する人々や組織を見つけることができます。
スポンサー
研究記録日
これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。
主要日程の研究
研究開始 (実際)
2024年6月1日
一次修了 (実際)
2025年3月31日
研究の完了 (実際)
2025年5月31日
試験登録日
最初に提出
2026年6月8日
QC基準を満たした最初の提出物
2026年6月8日
最初の投稿 (実際)
2026年6月12日
学習記録の更新
投稿された最後の更新 (実際)
2026年6月12日
QC基準を満たした最後の更新が送信されました
2026年6月8日
最終確認日
2026年6月1日
詳しくは
本研究に関する用語
追加の関連 MeSH 用語
その他の研究ID番号
- 2022ZDSYLL328-P01
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
いいえ
米国FDA規制機器製品の研究
いいえ
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。