Simultaneous T2-FLAIR and T1 Brain MRI With ENRAGED FLAIR in Multiple Sclerosis (ENRAGED FLAIR)
Evaluation of a Combined MR Sequence for Simultaneous T2- and T1-Weighted Brain Imaging in Multiple Sclerosis
This study will evaluate a new brain MRI technique called ENRAGED FLAIR in patients with multiple sclerosis. MRI is central in the diagnosis and follow-up of multiple sclerosis because it can show inflammatory lesions in the brain. A standard MS brain MRI examination usually includes T2-FLAIR images, which are used to detect and assess MS lesions, and T1-weighted images, which provide anatomical information and help with interpretation of lesion location.
These image types are usually acquired as separate scans. ENRAGED FLAIR is designed to acquire both T2-FLAIR and T1-weighted images during the same MRI sequence. The purpose of this study is to compare ENRAGED FLAIR with standard clinical MRI in patients with multiple sclerosis.
Adult patients with multiple sclerosis who are already scheduled for a clinical brain MRI may be asked to participate. Participants will undergo one additional MRI sequence during the same visit. No extra contrast agent will be given, and no extra visit is required. The additional scan is expected to increase the examination time by about 5 to 10 minutes.
The study will assess whether ENRAGED FLAIR provides image quality and MS lesion visualization comparable to standard MRI. If successful, this technique may help shorten future MRI examinations for patients with multiple sclerosis while preserving clinically useful image information.
調査の概要
詳細な説明
Multiple sclerosis (MS) is commonly monitored with brain MRI. T2-FLAIR imaging is central for detecting and following MS lesions, while T1-weighted imaging provides anatomical information that supports lesion localization and interpretation. In routine clinical MRI, these contrasts are usually acquired as separate sequences, which increases examination time.
ENRAGED FLAIR is a combined MRI acquisition designed to generate both 3D T2-FLAIR and T1-weighted brain images from a single sequence. The method uses otherwise unused recovery time in a FLAIR acquisition to acquire T1-weighted data. This may improve scan efficiency while preserving the clinically important information from both contrasts.
This study is a prospective intra-individual comparison in adult patients with MS undergoing clinically indicated brain MRI. Each participant will undergo standard clinical MRI sequences and one additional ENRAGED FLAIR acquisition during the same examination. No additional contrast agent or study visit is required.
Images from ENRAGED FLAIR will be compared with standard clinical T2-FLAIR and T1-weighted images. The evaluation will focus on MS lesion visualization, diagnostic image quality, and whether the simultaneously acquired T1-weighted images provide sufficient anatomical information for interpretation. Because each participant undergoes both standard MRI and ENRAGED FLAIR, each participant serves as their own control.
The study is intended to determine whether ENRAGED FLAIR can provide image quality comparable to standard MRI in MS while potentially enabling shorter future brain MRI protocols.
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
-
Stockholm、スウェーデン
- Karolinska Universitetssjukhuset
-
-
参加基準
適格基準
就学可能な年齢
- 大人
- 高齢者
健康ボランティアの受け入れ
説明
Inclusion Criteria:
- Adult patients, 18 years of age or older
- Diagnosis of multiple sclerosis
- Scheduled for a clinical brain MRI examination including T2-FLAIR and T1-weighted imaging
- Able to provide written informed consent
Exclusion Criteria:
- Age under 18 years
- Severe claustrophobia or inability to tolerate the additional MRI acquisition time
- Inability to provide written informed consent
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:診断
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:ENRAGED FLAIR MRI
Participants undergo standard clinical brain MRI and one additional ENRAGED FLAIR MRI acquisition during the same examination.
ENRAGED FLAIR images will be compared with standard clinical T2-FLAIR and T1-weighted images acquired in the same participant.
|
ENRAGED FLAIR is a combined MRI acquisition designed to generate both 3D T2-FLAIR and T1-weighted brain images from a single sequence.
The additional sequence is acquired during the same clinical MRI examination and does not involve extra contrast agent or an additional study visit.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
MRI Acquisition Time
時間枠:From start to completion of each MRI acquisition used for the scan-time comparison, assessed up to 1 day.
|
Acquisition time for ENRAGED FLAIR will be compared with the combined acquisition time of the corresponding standard clinical T2-FLAIR and T1-weighted MRI sequences in the same examination.
|
From start to completion of each MRI acquisition used for the scan-time comparison, assessed up to 1 day.
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
T2-FLAIR Relative Diagnostic Image Quality Score on a 5-Point Preference Scale
時間枠:At image review after the MRI examination, up to 12 months after enrollment
|
Blinded neuroradiologists will compare ENRAGED FLAIR-derived T2-FLAIR images with standard clinical T2-FLAIR images for MS lesion assessment and routine clinical interpretation using a 5-point relative diagnostic image quality scale.
Scores range from 1 to 5: 1 = standard clinical T2-FLAIR strongly preferred, 2 = standard clinical T2-FLAIR slightly preferred, 3 = no preference/equivalent diagnostic quality, 4 = ENRAGED FLAIR-derived T2-FLAIR slightly preferred, and 5 = ENRAGED FLAIR-derived T2-FLAIR strongly preferred.
Higher scores favor ENRAGED FLAIR.
|
At image review after the MRI examination, up to 12 months after enrollment
|
|
T1-Weighted Relative Diagnostic Image Quality Score on a 5-Point Preference Scale
時間枠:At image review after the MRI examination, up to 12 months after enrollment.
|
Blinded neuroradiologists will compare ENRAGED FLAIR-derived T1-weighted images with standard clinical T1-weighted images for anatomical interpretability and support of MS lesion localization using a 5-point relative diagnostic image quality scale.
Scores range from 1 to 5: 1 = standard clinical T1-weighted image strongly preferred, 2 = standard clinical T1-weighted image slightly preferred, 3 = no preference/equivalent diagnostic quality, 4 = ENRAGED FLAIR-derived T1-weighted image slightly preferred, and 5 = ENRAGED FLAIR-derived T1-weighted image strongly preferred.
Higher scores favor ENRAGED FLAIR.
|
At image review after the MRI examination, up to 12 months after enrollment.
|
|
MS Lesion Volume Agreement
時間枠:After image processing and analysis, up to 12 months after enrollment
|
MS lesion volumes derived from ENRAGED FLAIR images will be compared with lesion volumes derived from standard clinical T2-FLAIR images using automated or semi-automated lesion segmentation.
|
After image processing and analysis, up to 12 months after enrollment
|
|
Automatic Brain Segmentation Agreement
時間枠:After image processing and analysis, up to 12 months after enrollment
|
Brain tissue segmentation results derived from ENRAGED FLAIR images will be compared with segmentation results derived from standard clinical MRI images using automated brain segmentation software.
Agreement will be assessed for relevant volumetric outputs used in MS image analysis.
|
After image processing and analysis, up to 12 months after enrollment
|
協力者と研究者
スポンサー
捜査官
- 主任研究者:Karl Henric Rydén, PhD、Karolinska University Hospital
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
キーワード
追加の関連 MeSH 用語
その他の研究ID番号
- K 2026-6150
- 2026-01765-01 (その他の識別子:Swedish Ethical Review Authority)
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。