Tato stránka byla automaticky přeložena a přesnost překladu není zaručena. Podívejte se prosím na anglická verze pro zdrojový text.

Simultaneous T2-FLAIR and T1 Brain MRI With ENRAGED FLAIR in Multiple Sclerosis (ENRAGED FLAIR)

2. září 2026 aktualizováno: Henric Ryden, Region Stockholm

Evaluation of a Combined MR Sequence for Simultaneous T2- and T1-Weighted Brain Imaging in Multiple Sclerosis

This study will evaluate a new brain MRI technique called ENRAGED FLAIR in patients with multiple sclerosis. MRI is central in the diagnosis and follow-up of multiple sclerosis because it can show inflammatory lesions in the brain. A standard MS brain MRI examination usually includes T2-FLAIR images, which are used to detect and assess MS lesions, and T1-weighted images, which provide anatomical information and help with interpretation of lesion location.

These image types are usually acquired as separate scans. ENRAGED FLAIR is designed to acquire both T2-FLAIR and T1-weighted images during the same MRI sequence. The purpose of this study is to compare ENRAGED FLAIR with standard clinical MRI in patients with multiple sclerosis.

Adult patients with multiple sclerosis who are already scheduled for a clinical brain MRI may be asked to participate. Participants will undergo one additional MRI sequence during the same visit. No extra contrast agent will be given, and no extra visit is required. The additional scan is expected to increase the examination time by about 5 to 10 minutes.

The study will assess whether ENRAGED FLAIR provides image quality and MS lesion visualization comparable to standard MRI. If successful, this technique may help shorten future MRI examinations for patients with multiple sclerosis while preserving clinically useful image information.

Přehled studie

Postavení

Dokončeno

Detailní popis

Multiple sclerosis (MS) is commonly monitored with brain MRI. T2-FLAIR imaging is central for detecting and following MS lesions, while T1-weighted imaging provides anatomical information that supports lesion localization and interpretation. In routine clinical MRI, these contrasts are usually acquired as separate sequences, which increases examination time.

ENRAGED FLAIR is a combined MRI acquisition designed to generate both 3D T2-FLAIR and T1-weighted brain images from a single sequence. The method uses otherwise unused recovery time in a FLAIR acquisition to acquire T1-weighted data. This may improve scan efficiency while preserving the clinically important information from both contrasts.

This study is a prospective intra-individual comparison in adult patients with MS undergoing clinically indicated brain MRI. Each participant will undergo standard clinical MRI sequences and one additional ENRAGED FLAIR acquisition during the same examination. No additional contrast agent or study visit is required.

Images from ENRAGED FLAIR will be compared with standard clinical T2-FLAIR and T1-weighted images. The evaluation will focus on MS lesion visualization, diagnostic image quality, and whether the simultaneously acquired T1-weighted images provide sufficient anatomical information for interpretation. Because each participant undergoes both standard MRI and ENRAGED FLAIR, each participant serves as their own control.

The study is intended to determine whether ENRAGED FLAIR can provide image quality comparable to standard MRI in MS while potentially enabling shorter future brain MRI protocols.

Typ studie

Intervenční

Zápis (Aktuální)

11

Fáze

  • Nelze použít

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní místa

      • Stockholm, Švédsko
        • Karolinska Universitetssjukhuset

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

  • Dospělý
  • Starší dospělý

Přijímá zdravé dobrovolníky

Ano

Popis

Inclusion Criteria:

  • Adult patients, 18 years of age or older
  • Diagnosis of multiple sclerosis
  • Scheduled for a clinical brain MRI examination including T2-FLAIR and T1-weighted imaging
  • Able to provide written informed consent

Exclusion Criteria:

  • Age under 18 years
  • Severe claustrophobia or inability to tolerate the additional MRI acquisition time
  • Inability to provide written informed consent

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Primární účel: Diagnostický
  • Přidělení: N/A
  • Intervenční model: Přiřazení jedné skupiny
  • Maskování: Žádné (otevřený štítek)

Zbraně a zásahy

Skupina účastníků / Arm
Intervence / Léčba
Experimentální: ENRAGED FLAIR MRI
Participants undergo standard clinical brain MRI and one additional ENRAGED FLAIR MRI acquisition during the same examination. ENRAGED FLAIR images will be compared with standard clinical T2-FLAIR and T1-weighted images acquired in the same participant.
ENRAGED FLAIR is a combined MRI acquisition designed to generate both 3D T2-FLAIR and T1-weighted brain images from a single sequence. The additional sequence is acquired during the same clinical MRI examination and does not involve extra contrast agent or an additional study visit.

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
MRI Acquisition Time
Časové okno: From start to completion of each MRI acquisition used for the scan-time comparison, assessed up to 1 day.
Acquisition time for ENRAGED FLAIR will be compared with the combined acquisition time of the corresponding standard clinical T2-FLAIR and T1-weighted MRI sequences in the same examination.
From start to completion of each MRI acquisition used for the scan-time comparison, assessed up to 1 day.

Sekundární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
T2-FLAIR Relative Diagnostic Image Quality Score on a 5-Point Preference Scale
Časové okno: At image review after the MRI examination, up to 12 months after enrollment
Blinded neuroradiologists will compare ENRAGED FLAIR-derived T2-FLAIR images with standard clinical T2-FLAIR images for MS lesion assessment and routine clinical interpretation using a 5-point relative diagnostic image quality scale. Scores range from 1 to 5: 1 = standard clinical T2-FLAIR strongly preferred, 2 = standard clinical T2-FLAIR slightly preferred, 3 = no preference/equivalent diagnostic quality, 4 = ENRAGED FLAIR-derived T2-FLAIR slightly preferred, and 5 = ENRAGED FLAIR-derived T2-FLAIR strongly preferred. Higher scores favor ENRAGED FLAIR.
At image review after the MRI examination, up to 12 months after enrollment
T1-Weighted Relative Diagnostic Image Quality Score on a 5-Point Preference Scale
Časové okno: At image review after the MRI examination, up to 12 months after enrollment.
Blinded neuroradiologists will compare ENRAGED FLAIR-derived T1-weighted images with standard clinical T1-weighted images for anatomical interpretability and support of MS lesion localization using a 5-point relative diagnostic image quality scale. Scores range from 1 to 5: 1 = standard clinical T1-weighted image strongly preferred, 2 = standard clinical T1-weighted image slightly preferred, 3 = no preference/equivalent diagnostic quality, 4 = ENRAGED FLAIR-derived T1-weighted image slightly preferred, and 5 = ENRAGED FLAIR-derived T1-weighted image strongly preferred. Higher scores favor ENRAGED FLAIR.
At image review after the MRI examination, up to 12 months after enrollment.
MS Lesion Volume Agreement
Časové okno: After image processing and analysis, up to 12 months after enrollment
MS lesion volumes derived from ENRAGED FLAIR images will be compared with lesion volumes derived from standard clinical T2-FLAIR images using automated or semi-automated lesion segmentation.
After image processing and analysis, up to 12 months after enrollment
Automatic Brain Segmentation Agreement
Časové okno: After image processing and analysis, up to 12 months after enrollment
Brain tissue segmentation results derived from ENRAGED FLAIR images will be compared with segmentation results derived from standard clinical MRI images using automated brain segmentation software. Agreement will be assessed for relevant volumetric outputs used in MS image analysis.
After image processing and analysis, up to 12 months after enrollment

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Vyšetřovatelé

  • Vrchní vyšetřovatel: Karl Henric Rydén, PhD, Karolinska University Hospital

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Aktuální)

10. srpna 2026

Primární dokončení (Aktuální)

31. srpna 2026

Dokončení studie (Aktuální)

31. srpna 2026

Termíny zápisu do studia

První předloženo

23. června 2026

První předloženo, které splnilo kritéria kontroly kvality

1. července 2026

První zveřejněno (Aktuální)

7. července 2026

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

3. září 2026

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

2. září 2026

Naposledy ověřeno

1. června 2026

Více informací

Termíny související s touto studií

Plán pro data jednotlivých účastníků (IPD)

Plánujete sdílet data jednotlivých účastníků (IPD)?

NE

Popis plánu IPD

Individual participant data will not be shared because the study uses pseudonymized clinical MRI data and health-related information that are subject to ethical approval, GDPR, and institutional data protection requirements.

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .

Předplatit