Simultaneous T2-FLAIR and T1 Brain MRI With ENRAGED FLAIR in Multiple Sclerosis (ENRAGED FLAIR)

2026年9月2日 更新者:Henric Ryden、Region Stockholm

Evaluation of a Combined MR Sequence for Simultaneous T2- and T1-Weighted Brain Imaging in Multiple Sclerosis

This study will evaluate a new brain MRI technique called ENRAGED FLAIR in patients with multiple sclerosis. MRI is central in the diagnosis and follow-up of multiple sclerosis because it can show inflammatory lesions in the brain. A standard MS brain MRI examination usually includes T2-FLAIR images, which are used to detect and assess MS lesions, and T1-weighted images, which provide anatomical information and help with interpretation of lesion location.

These image types are usually acquired as separate scans. ENRAGED FLAIR is designed to acquire both T2-FLAIR and T1-weighted images during the same MRI sequence. The purpose of this study is to compare ENRAGED FLAIR with standard clinical MRI in patients with multiple sclerosis.

Adult patients with multiple sclerosis who are already scheduled for a clinical brain MRI may be asked to participate. Participants will undergo one additional MRI sequence during the same visit. No extra contrast agent will be given, and no extra visit is required. The additional scan is expected to increase the examination time by about 5 to 10 minutes.

The study will assess whether ENRAGED FLAIR provides image quality and MS lesion visualization comparable to standard MRI. If successful, this technique may help shorten future MRI examinations for patients with multiple sclerosis while preserving clinically useful image information.

研究概览

地位

完全的

详细说明

Multiple sclerosis (MS) is commonly monitored with brain MRI. T2-FLAIR imaging is central for detecting and following MS lesions, while T1-weighted imaging provides anatomical information that supports lesion localization and interpretation. In routine clinical MRI, these contrasts are usually acquired as separate sequences, which increases examination time.

ENRAGED FLAIR is a combined MRI acquisition designed to generate both 3D T2-FLAIR and T1-weighted brain images from a single sequence. The method uses otherwise unused recovery time in a FLAIR acquisition to acquire T1-weighted data. This may improve scan efficiency while preserving the clinically important information from both contrasts.

This study is a prospective intra-individual comparison in adult patients with MS undergoing clinically indicated brain MRI. Each participant will undergo standard clinical MRI sequences and one additional ENRAGED FLAIR acquisition during the same examination. No additional contrast agent or study visit is required.

Images from ENRAGED FLAIR will be compared with standard clinical T2-FLAIR and T1-weighted images. The evaluation will focus on MS lesion visualization, diagnostic image quality, and whether the simultaneously acquired T1-weighted images provide sufficient anatomical information for interpretation. Because each participant undergoes both standard MRI and ENRAGED FLAIR, each participant serves as their own control.

The study is intended to determine whether ENRAGED FLAIR can provide image quality comparable to standard MRI in MS while potentially enabling shorter future brain MRI protocols.

研究类型

介入性

注册 (实际的)

11

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

      • Stockholm、瑞典
        • Karolinska Universitetssjukhuset

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人
  • 年长者

接受健康志愿者

是的

描述

Inclusion Criteria:

  • Adult patients, 18 years of age or older
  • Diagnosis of multiple sclerosis
  • Scheduled for a clinical brain MRI examination including T2-FLAIR and T1-weighted imaging
  • Able to provide written informed consent

Exclusion Criteria:

  • Age under 18 years
  • Severe claustrophobia or inability to tolerate the additional MRI acquisition time
  • Inability to provide written informed consent

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:诊断
  • 分配:不适用
  • 介入模型:单组作业
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
实验性的:ENRAGED FLAIR MRI
Participants undergo standard clinical brain MRI and one additional ENRAGED FLAIR MRI acquisition during the same examination. ENRAGED FLAIR images will be compared with standard clinical T2-FLAIR and T1-weighted images acquired in the same participant.
ENRAGED FLAIR is a combined MRI acquisition designed to generate both 3D T2-FLAIR and T1-weighted brain images from a single sequence. The additional sequence is acquired during the same clinical MRI examination and does not involve extra contrast agent or an additional study visit.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
MRI Acquisition Time
大体时间:From start to completion of each MRI acquisition used for the scan-time comparison, assessed up to 1 day.
Acquisition time for ENRAGED FLAIR will be compared with the combined acquisition time of the corresponding standard clinical T2-FLAIR and T1-weighted MRI sequences in the same examination.
From start to completion of each MRI acquisition used for the scan-time comparison, assessed up to 1 day.

次要结果测量

结果测量
措施说明
大体时间
T2-FLAIR Relative Diagnostic Image Quality Score on a 5-Point Preference Scale
大体时间:At image review after the MRI examination, up to 12 months after enrollment
Blinded neuroradiologists will compare ENRAGED FLAIR-derived T2-FLAIR images with standard clinical T2-FLAIR images for MS lesion assessment and routine clinical interpretation using a 5-point relative diagnostic image quality scale. Scores range from 1 to 5: 1 = standard clinical T2-FLAIR strongly preferred, 2 = standard clinical T2-FLAIR slightly preferred, 3 = no preference/equivalent diagnostic quality, 4 = ENRAGED FLAIR-derived T2-FLAIR slightly preferred, and 5 = ENRAGED FLAIR-derived T2-FLAIR strongly preferred. Higher scores favor ENRAGED FLAIR.
At image review after the MRI examination, up to 12 months after enrollment
T1-Weighted Relative Diagnostic Image Quality Score on a 5-Point Preference Scale
大体时间:At image review after the MRI examination, up to 12 months after enrollment.
Blinded neuroradiologists will compare ENRAGED FLAIR-derived T1-weighted images with standard clinical T1-weighted images for anatomical interpretability and support of MS lesion localization using a 5-point relative diagnostic image quality scale. Scores range from 1 to 5: 1 = standard clinical T1-weighted image strongly preferred, 2 = standard clinical T1-weighted image slightly preferred, 3 = no preference/equivalent diagnostic quality, 4 = ENRAGED FLAIR-derived T1-weighted image slightly preferred, and 5 = ENRAGED FLAIR-derived T1-weighted image strongly preferred. Higher scores favor ENRAGED FLAIR.
At image review after the MRI examination, up to 12 months after enrollment.
MS Lesion Volume Agreement
大体时间:After image processing and analysis, up to 12 months after enrollment
MS lesion volumes derived from ENRAGED FLAIR images will be compared with lesion volumes derived from standard clinical T2-FLAIR images using automated or semi-automated lesion segmentation.
After image processing and analysis, up to 12 months after enrollment
Automatic Brain Segmentation Agreement
大体时间:After image processing and analysis, up to 12 months after enrollment
Brain tissue segmentation results derived from ENRAGED FLAIR images will be compared with segmentation results derived from standard clinical MRI images using automated brain segmentation software. Agreement will be assessed for relevant volumetric outputs used in MS image analysis.
After image processing and analysis, up to 12 months after enrollment

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Karl Henric Rydén, PhD、Karolinska University Hospital

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2026年8月10日

初级完成 (实际的)

2026年8月31日

研究完成 (实际的)

2026年8月31日

研究注册日期

首次提交

2026年6月23日

首先提交符合 QC 标准的

2026年7月1日

首次发布 (实际的)

2026年7月7日

研究记录更新

最后更新发布 (实际的)

2026年9月3日

上次提交的符合 QC 标准的更新

2026年9月2日

最后验证

2026年6月1日

更多信息

与本研究相关的术语

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

IPD 计划说明

Individual participant data will not be shared because the study uses pseudonymized clinical MRI data and health-related information that are subject to ethical approval, GDPR, and institutional data protection requirements.

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅