このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Early Loading of UV-Functionalized Dental Implants

2026年7月3日 更新者:Damascus University

Effect of Early Loading on Ultraviolet Photofunctionalized Dental Implants: A Randomized Controlled Triple-Blind Split-Mouth Clinical Trial

This randomized controlled triple-blind split-mouth clinical trial was conducted to evaluate the effect of early loading on ultraviolet photofunctionalized dental implants placed in the posterior mandible. Ten patients received a total of 20 implants, with each participant receiving one ultraviolet photofunctionalized implant and one non-photofunctionalized control implant. Ultraviolet photofunctionalization was performed 24 hours before implant placement by an independent investigator. All implants were early loaded 4 weeks after surgery. Implant stability was assessed using Resonance Frequency Analysis (RFA) and expressed as Implant Stability Quotient (ISQ) values at implant placement, 3 weeks, and 4 weeks after surgery. Peri-implant marginal bone loss was evaluated radiographically during a one-year follow-up period. The study compared implant stability and radiographic outcomes between ultraviolet photofunctionalized and conventional implants under early loading conditions.

調査の概要

詳細な説明

Dental implants have become a predictable and widely accepted treatment modality for the rehabilitation of partially and completely edentulous patients.

Successful implant therapy depends largely on achieving and maintaining osseointegration between the implant surface and the surrounding bone. Traditionally, implants were left unloaded for several months to allow sufficient healing and osseointegration before functional loading. However, the growing demand for shorter treatment times has encouraged the development of early loading protocols. Early loading of dental implants offers several clinical advantages, including reduced treatment duration, earlier restoration of function and esthetics, and improved patient satisfaction. Nevertheless, successful early loading requires adequate implant stability during the critical healing period. Consequently, considerable research has focused on improving implant surface characteristics to accelerate osseointegration and enhance implant stability. Ultraviolet (UV) photofunctionalization is a surface modification technique that involves exposing titanium implants to ultraviolet light before placement. This process reduces hydrocarbon contamination on the implant surface, increases surface hydrophilicity, and enhances the biological activity of titanium. Previous experimental and clinical studies have suggested that UV photofunctionalization may improve cell attachment, promote bone formation, increase bone-to-implant contact, and enhance implant stability during the early stages of healing. This randomized controlled triple-blind split-mouth clinical trial was conducted to evaluate the effect of early loading on ultraviolet photofunctionalized dental implants placed in the posterior mandible. Ten patients requiring bilateral implant-supported rehabilitation in comparable posterior mandibular sites were included. A total of twenty implants were placed, with each participant receiving one ultraviolet photofunctionalized implant and one non photofunctionalized control implant. Implant allocation was randomized, and ultraviolet photofunctionalization was performed by an independent investigator 24 hours before surgery. Participants, the surgeon/outcome assessor, and the statistician were blinded to treatment allocation throughout the study. All implants were restored using an early loading protocol four weeks after implant placement. Implant stability was evaluated using Resonance Frequency Analysis (RFA) and expressed as Implant Stability Quotient (ISQ) values. Measurements were obtained at implant placement, three weeks after surgery, and four weeks after surgery. In addition, peri-implant marginal bone loss was assessed radiographically during a one-year follow-up period. The split-mouth design was selected to minimize inter-individual variability and allow direct comparison between test and control implants within the same participant. The study aimed to determine whether ultraviolet photofunctionalization could improve implant stability and support the clinical performance of early-loaded dental implants in the posterior mandible.

研究の種類

介入

入学 (実際)

10

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

      • Damascus、シリア
        • Department of Oral and Maxillofacial Surgery Faculty of Dentistry Damascus University Damascus, Syrian Arab Republic

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人
  • 高齢者

健康ボランティアの受け入れ

いいえ

説明

Inclusion Criteria:

  1. Willingness to participate in the study and provision of written informed consent, with commitment to follow-up visits and study instructions.
  2. Good oral hygiene and satisfactory oral health status.
  3. Adults aged 18 years or older.
  4. Good general health with no systemic conditions contraindicating dental implant placement.
  5. Requirement for dental implant placement in the posterior mandible, with at least 6 months elapsed since tooth extraction.
  6. Adequate bone volume to allow implant placement without the need for bone grafting procedures.

Exclusion Criteria:

  1. Patients with parafunctional habits, including bruxism.
  2. Heavy smokers consuming more than 10 cigarettes per day.
  3. Patients receiving radiotherapy or chemotherapy.
  4. Long-term use of medications known to affect bone metabolism, such as corticosteroids.
  5. Pregnant or breastfeeding women.
  6. Insufficient interocclusal space for prosthetic rehabilitation.
  7. Patients with metabolic or bone disorders affecting bone quality or density, including hyperparathyroidism and osteoporosis.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:処理
  • 割り当て:ランダム化
  • 介入モデル:並列代入
  • マスキング:4倍

武器と介入

参加者グループ / アーム
介入・治療
実験的:Arm 1: Ultraviolet Photofunctionalized Dental Implants
This arm included dental implants that underwent ultraviolet photofunctionalization 24 hours before implant placement. Each participant received one ultraviolet photofunctionalized implant in a posterior mandibular edentulous site according to the randomized split-mouth design.
Dental implants assigned to the experimental arm underwent ultraviolet photofunctionalization 24 hours before implant placement by an independent investigator. The implants were subsequently placed in posterior mandibular edentulous sites and restored using an early loading protocol 4 weeks after surgery
アクティブコンパレータ:Conventional Dental Implants
This arm included dental implants placed without ultraviolet photofunctionalization. Each participant received one conventional implant in a comparable posterior mandibular edentulous site according to the randomized split-mouth design.
Dental implants assigned to the control arm were placed without ultraviolet photofunctionalization. The implants were inserted in comparable posterior mandibular edentulous sites and restored using the same early loading protocol 4 weeks after surgery

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Implant Stability Quotient (ISQ)
時間枠:At implant placement (baseline), 3 weeks after implant placement, and 4 weeks after implant placement.
Implant stability was measured using Resonance Frequency Analysis (RFA) with the Mega ISQ II device. Stability values were recorded as Implant Stability Quotient (ISQ) scores ranging from 1 to 100, with higher values indicating greater implant stability. Measurements were obtained immediately after implant placement, at 3 weeks, and at 4 weeks postoperatively before early loading.
At implant placement (baseline), 3 weeks after implant placement, and 4 weeks after implant placement.

二次結果の測定

結果測定
メジャーの説明
時間枠
Peri-implant Marginal Bone Loss
時間枠:At implant placement (baseline) and one year after early loading.
Peri-implant marginal bone loss was evaluated using standardized periapical radiographs obtained immediately after implant placement and one year after early loading. Measurements were performed by assessing the vertical distance from the implant platform to the first bone-to-implant contact on both mesial and distal aspects of the implant. Bone level changes were calculated and recorded in millimeters (mm), with greater values indicating increased marginal bone loss
At implant placement (baseline) and one year after early loading.

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

捜査官

  • スタディチェア:Issam Alkhouri, DDS, Phd、Faculty of Dentistry, Damascus University, Damascus, Syria
  • 主任研究者:Awab Al-Midani, Master's Degree Candidate、Faculty of Dentistry, Damascus University, Damascus, Syria

出版物と役立つリンク

研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2022年12月11日

一次修了 (実際)

2025年2月8日

研究の完了 (実際)

2026年3月8日

試験登録日

最初に提出

2026年7月3日

QC基準を満たした最初の提出物

2026年7月3日

最初の投稿 (実際)

2026年7月10日

学習記録の更新

投稿された最後の更新 (実際)

2026年7月10日

QC基準を満たした最後の更新が送信されました

2026年7月3日

最終確認日

2026年7月1日

詳しくは

本研究に関する用語

その他の研究ID番号

  • UDDS-2026-OralMaxillofacial-02

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する