此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Early Loading of UV-Functionalized Dental Implants

2026年7月3日 更新者:Damascus University

Effect of Early Loading on Ultraviolet Photofunctionalized Dental Implants: A Randomized Controlled Triple-Blind Split-Mouth Clinical Trial

This randomized controlled triple-blind split-mouth clinical trial was conducted to evaluate the effect of early loading on ultraviolet photofunctionalized dental implants placed in the posterior mandible. Ten patients received a total of 20 implants, with each participant receiving one ultraviolet photofunctionalized implant and one non-photofunctionalized control implant. Ultraviolet photofunctionalization was performed 24 hours before implant placement by an independent investigator. All implants were early loaded 4 weeks after surgery. Implant stability was assessed using Resonance Frequency Analysis (RFA) and expressed as Implant Stability Quotient (ISQ) values at implant placement, 3 weeks, and 4 weeks after surgery. Peri-implant marginal bone loss was evaluated radiographically during a one-year follow-up period. The study compared implant stability and radiographic outcomes between ultraviolet photofunctionalized and conventional implants under early loading conditions.

研究概览

详细说明

Dental implants have become a predictable and widely accepted treatment modality for the rehabilitation of partially and completely edentulous patients.

Successful implant therapy depends largely on achieving and maintaining osseointegration between the implant surface and the surrounding bone. Traditionally, implants were left unloaded for several months to allow sufficient healing and osseointegration before functional loading. However, the growing demand for shorter treatment times has encouraged the development of early loading protocols. Early loading of dental implants offers several clinical advantages, including reduced treatment duration, earlier restoration of function and esthetics, and improved patient satisfaction. Nevertheless, successful early loading requires adequate implant stability during the critical healing period. Consequently, considerable research has focused on improving implant surface characteristics to accelerate osseointegration and enhance implant stability. Ultraviolet (UV) photofunctionalization is a surface modification technique that involves exposing titanium implants to ultraviolet light before placement. This process reduces hydrocarbon contamination on the implant surface, increases surface hydrophilicity, and enhances the biological activity of titanium. Previous experimental and clinical studies have suggested that UV photofunctionalization may improve cell attachment, promote bone formation, increase bone-to-implant contact, and enhance implant stability during the early stages of healing. This randomized controlled triple-blind split-mouth clinical trial was conducted to evaluate the effect of early loading on ultraviolet photofunctionalized dental implants placed in the posterior mandible. Ten patients requiring bilateral implant-supported rehabilitation in comparable posterior mandibular sites were included. A total of twenty implants were placed, with each participant receiving one ultraviolet photofunctionalized implant and one non photofunctionalized control implant. Implant allocation was randomized, and ultraviolet photofunctionalization was performed by an independent investigator 24 hours before surgery. Participants, the surgeon/outcome assessor, and the statistician were blinded to treatment allocation throughout the study. All implants were restored using an early loading protocol four weeks after implant placement. Implant stability was evaluated using Resonance Frequency Analysis (RFA) and expressed as Implant Stability Quotient (ISQ) values. Measurements were obtained at implant placement, three weeks after surgery, and four weeks after surgery. In addition, peri-implant marginal bone loss was assessed radiographically during a one-year follow-up period. The split-mouth design was selected to minimize inter-individual variability and allow direct comparison between test and control implants within the same participant. The study aimed to determine whether ultraviolet photofunctionalization could improve implant stability and support the clinical performance of early-loaded dental implants in the posterior mandible.

研究类型

介入性

注册 (实际的)

10

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

      • Damascus、叙利亚
        • Department of Oral and Maxillofacial Surgery Faculty of Dentistry Damascus University Damascus, Syrian Arab Republic

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人
  • 年长者

接受健康志愿者

不

描述

Inclusion Criteria:

  1. Willingness to participate in the study and provision of written informed consent, with commitment to follow-up visits and study instructions.
  2. Good oral hygiene and satisfactory oral health status.
  3. Adults aged 18 years or older.
  4. Good general health with no systemic conditions contraindicating dental implant placement.
  5. Requirement for dental implant placement in the posterior mandible, with at least 6 months elapsed since tooth extraction.
  6. Adequate bone volume to allow implant placement without the need for bone grafting procedures.

Exclusion Criteria:

  1. Patients with parafunctional habits, including bruxism.
  2. Heavy smokers consuming more than 10 cigarettes per day.
  3. Patients receiving radiotherapy or chemotherapy.
  4. Long-term use of medications known to affect bone metabolism, such as corticosteroids.
  5. Pregnant or breastfeeding women.
  6. Insufficient interocclusal space for prosthetic rehabilitation.
  7. Patients with metabolic or bone disorders affecting bone quality or density, including hyperparathyroidism and osteoporosis.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:四人间

武器和干预

参与者组/臂
干预/治疗
实验性的:Arm 1: Ultraviolet Photofunctionalized Dental Implants
This arm included dental implants that underwent ultraviolet photofunctionalization 24 hours before implant placement. Each participant received one ultraviolet photofunctionalized implant in a posterior mandibular edentulous site according to the randomized split-mouth design.
Dental implants assigned to the experimental arm underwent ultraviolet photofunctionalization 24 hours before implant placement by an independent investigator. The implants were subsequently placed in posterior mandibular edentulous sites and restored using an early loading protocol 4 weeks after surgery
有源比较器:Conventional Dental Implants
This arm included dental implants placed without ultraviolet photofunctionalization. Each participant received one conventional implant in a comparable posterior mandibular edentulous site according to the randomized split-mouth design.
Dental implants assigned to the control arm were placed without ultraviolet photofunctionalization. The implants were inserted in comparable posterior mandibular edentulous sites and restored using the same early loading protocol 4 weeks after surgery

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Implant Stability Quotient (ISQ)
大体时间:At implant placement (baseline), 3 weeks after implant placement, and 4 weeks after implant placement.
Implant stability was measured using Resonance Frequency Analysis (RFA) with the Mega ISQ II device. Stability values were recorded as Implant Stability Quotient (ISQ) scores ranging from 1 to 100, with higher values indicating greater implant stability. Measurements were obtained immediately after implant placement, at 3 weeks, and at 4 weeks postoperatively before early loading.
At implant placement (baseline), 3 weeks after implant placement, and 4 weeks after implant placement.

次要结果测量

结果测量
措施说明
大体时间
Peri-implant Marginal Bone Loss
大体时间:At implant placement (baseline) and one year after early loading.
Peri-implant marginal bone loss was evaluated using standardized periapical radiographs obtained immediately after implant placement and one year after early loading. Measurements were performed by assessing the vertical distance from the implant platform to the first bone-to-implant contact on both mesial and distal aspects of the implant. Bone level changes were calculated and recorded in millimeters (mm), with greater values indicating increased marginal bone loss
At implant placement (baseline) and one year after early loading.

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 学习椅:Issam Alkhouri, DDS, Phd、Faculty of Dentistry, Damascus University, Damascus, Syria
  • 首席研究员:Awab Al-Midani, Master's Degree Candidate、Faculty of Dentistry, Damascus University, Damascus, Syria

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2022年12月11日

初级完成 (实际的)

2025年2月8日

研究完成 (实际的)

2026年3月8日

研究注册日期

首次提交

2026年7月3日

首先提交符合 QC 标准的

2026年7月3日

首次发布 (实际的)

2026年7月10日

研究记录更新

最后更新发布 (实际的)

2026年7月10日

上次提交的符合 QC 标准的更新

2026年7月3日

最后验证

2026年7月1日

更多信息

与本研究相关的术语

其他研究编号

  • UDDS-2026-OralMaxillofacial-02

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅