이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

Early Loading of UV-Functionalized Dental Implants

2026년 7월 3일 업데이트: Damascus University

Effect of Early Loading on Ultraviolet Photofunctionalized Dental Implants: A Randomized Controlled Triple-Blind Split-Mouth Clinical Trial

This randomized controlled triple-blind split-mouth clinical trial was conducted to evaluate the effect of early loading on ultraviolet photofunctionalized dental implants placed in the posterior mandible. Ten patients received a total of 20 implants, with each participant receiving one ultraviolet photofunctionalized implant and one non-photofunctionalized control implant. Ultraviolet photofunctionalization was performed 24 hours before implant placement by an independent investigator. All implants were early loaded 4 weeks after surgery. Implant stability was assessed using Resonance Frequency Analysis (RFA) and expressed as Implant Stability Quotient (ISQ) values at implant placement, 3 weeks, and 4 weeks after surgery. Peri-implant marginal bone loss was evaluated radiographically during a one-year follow-up period. The study compared implant stability and radiographic outcomes between ultraviolet photofunctionalized and conventional implants under early loading conditions.

연구 개요

상세 설명

Dental implants have become a predictable and widely accepted treatment modality for the rehabilitation of partially and completely edentulous patients.

Successful implant therapy depends largely on achieving and maintaining osseointegration between the implant surface and the surrounding bone. Traditionally, implants were left unloaded for several months to allow sufficient healing and osseointegration before functional loading. However, the growing demand for shorter treatment times has encouraged the development of early loading protocols. Early loading of dental implants offers several clinical advantages, including reduced treatment duration, earlier restoration of function and esthetics, and improved patient satisfaction. Nevertheless, successful early loading requires adequate implant stability during the critical healing period. Consequently, considerable research has focused on improving implant surface characteristics to accelerate osseointegration and enhance implant stability. Ultraviolet (UV) photofunctionalization is a surface modification technique that involves exposing titanium implants to ultraviolet light before placement. This process reduces hydrocarbon contamination on the implant surface, increases surface hydrophilicity, and enhances the biological activity of titanium. Previous experimental and clinical studies have suggested that UV photofunctionalization may improve cell attachment, promote bone formation, increase bone-to-implant contact, and enhance implant stability during the early stages of healing. This randomized controlled triple-blind split-mouth clinical trial was conducted to evaluate the effect of early loading on ultraviolet photofunctionalized dental implants placed in the posterior mandible. Ten patients requiring bilateral implant-supported rehabilitation in comparable posterior mandibular sites were included. A total of twenty implants were placed, with each participant receiving one ultraviolet photofunctionalized implant and one non photofunctionalized control implant. Implant allocation was randomized, and ultraviolet photofunctionalization was performed by an independent investigator 24 hours before surgery. Participants, the surgeon/outcome assessor, and the statistician were blinded to treatment allocation throughout the study. All implants were restored using an early loading protocol four weeks after implant placement. Implant stability was evaluated using Resonance Frequency Analysis (RFA) and expressed as Implant Stability Quotient (ISQ) values. Measurements were obtained at implant placement, three weeks after surgery, and four weeks after surgery. In addition, peri-implant marginal bone loss was assessed radiographically during a one-year follow-up period. The split-mouth design was selected to minimize inter-individual variability and allow direct comparison between test and control implants within the same participant. The study aimed to determine whether ultraviolet photofunctionalization could improve implant stability and support the clinical performance of early-loaded dental implants in the posterior mandible.

연구 유형

중재적

등록 (실제)

10

단계

  • 해당 없음

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 장소

      • Damascus, 시리아
        • Department of Oral and Maxillofacial Surgery Faculty of Dentistry Damascus University Damascus, Syrian Arab Republic

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

  • 성인
  • 고령자

건강한 자원 봉사자를 받아들입니다

아니

설명

Inclusion Criteria:

  1. Willingness to participate in the study and provision of written informed consent, with commitment to follow-up visits and study instructions.
  2. Good oral hygiene and satisfactory oral health status.
  3. Adults aged 18 years or older.
  4. Good general health with no systemic conditions contraindicating dental implant placement.
  5. Requirement for dental implant placement in the posterior mandible, with at least 6 months elapsed since tooth extraction.
  6. Adequate bone volume to allow implant placement without the need for bone grafting procedures.

Exclusion Criteria:

  1. Patients with parafunctional habits, including bruxism.
  2. Heavy smokers consuming more than 10 cigarettes per day.
  3. Patients receiving radiotherapy or chemotherapy.
  4. Long-term use of medications known to affect bone metabolism, such as corticosteroids.
  5. Pregnant or breastfeeding women.
  6. Insufficient interocclusal space for prosthetic rehabilitation.
  7. Patients with metabolic or bone disorders affecting bone quality or density, including hyperparathyroidism and osteoporosis.

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 치료
  • 할당: 무작위
  • 중재 모델: 병렬 할당
  • 마스킹: 네 배로

무기와 개입

참가자 그룹 / 팔
개입 / 치료
실험적: Arm 1: Ultraviolet Photofunctionalized Dental Implants
This arm included dental implants that underwent ultraviolet photofunctionalization 24 hours before implant placement. Each participant received one ultraviolet photofunctionalized implant in a posterior mandibular edentulous site according to the randomized split-mouth design.
Dental implants assigned to the experimental arm underwent ultraviolet photofunctionalization 24 hours before implant placement by an independent investigator. The implants were subsequently placed in posterior mandibular edentulous sites and restored using an early loading protocol 4 weeks after surgery
활성 비교기: Conventional Dental Implants
This arm included dental implants placed without ultraviolet photofunctionalization. Each participant received one conventional implant in a comparable posterior mandibular edentulous site according to the randomized split-mouth design.
Dental implants assigned to the control arm were placed without ultraviolet photofunctionalization. The implants were inserted in comparable posterior mandibular edentulous sites and restored using the same early loading protocol 4 weeks after surgery

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Implant Stability Quotient (ISQ)
기간: At implant placement (baseline), 3 weeks after implant placement, and 4 weeks after implant placement.
Implant stability was measured using Resonance Frequency Analysis (RFA) with the Mega ISQ II device. Stability values were recorded as Implant Stability Quotient (ISQ) scores ranging from 1 to 100, with higher values indicating greater implant stability. Measurements were obtained immediately after implant placement, at 3 weeks, and at 4 weeks postoperatively before early loading.
At implant placement (baseline), 3 weeks after implant placement, and 4 weeks after implant placement.

2차 결과 측정

결과 측정
측정값 설명
기간
Peri-implant Marginal Bone Loss
기간: At implant placement (baseline) and one year after early loading.
Peri-implant marginal bone loss was evaluated using standardized periapical radiographs obtained immediately after implant placement and one year after early loading. Measurements were performed by assessing the vertical distance from the implant platform to the first bone-to-implant contact on both mesial and distal aspects of the implant. Bone level changes were calculated and recorded in millimeters (mm), with greater values indicating increased marginal bone loss
At implant placement (baseline) and one year after early loading.

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

수사관

  • 연구 의자: Issam Alkhouri, DDS, Phd, Faculty of Dentistry, Damascus University, Damascus, Syria
  • 수석 연구원: Awab Al-Midani, Master's Degree Candidate, Faculty of Dentistry, Damascus University, Damascus, Syria

간행물 및 유용한 링크

연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2022년 12월 11일

기본 완료 (실제)

2025년 2월 8일

연구 완료 (실제)

2026년 3월 8일

연구 등록 날짜

최초 제출

2026년 7월 3일

QC 기준을 충족하는 최초 제출

2026년 7월 3일

처음 게시됨 (실제)

2026년 7월 10일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 7월 10일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 7월 3일

마지막으로 확인됨

2026년 7월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • UDDS-2026-OralMaxillofacial-02

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

아니요

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .