Safety, Tolerability, and Accuracy of a Hydrogel-Based Wearable Dynamic Intraocular Pressure Sensor in Healthy Adults

Safety, Tolerability, and Accuracy of a Novel Hydrogel-Based Wearable Dynamic Intraocular Pressure Sensor in Healthy Adults: A Single-Center, Single-Arm Exploratory Clinical Trial

The occurrence and progression of eye diseases like glaucoma are closely related to intraocular pressure fluctuations. Traditional single-point intraocular pressure measurement methods cannot reflect daily dynamic changes and are prone to missing hidden intraocular pressure peaks, limiting precise diagnosis and individualized treatment. This project aims to evaluate the wearing safety and measurement accuracy of a new low-modulus, high-strength hydrogel wearable dynamic intraocular pressure sensor. This product adopts the form of smart contact lenses, fully embedding a micro sensor into a hydrogel lens, combined with an external antenna mount and a portable recorder to continuously detect and wirelessly record even slight changes in corneal curvature, thereby obtaining real-time intraocular pressure fluctuation trend data. Based on this, the objective of this study is to evaluate the safety, measurement accuracy and tolerabilityof a wearable dynamic intraocular pressure sensor based on a novel hydrogel in healthy volunteers.

調査の概要

状態

まだ募集していません

条件

研究の種類

介入

入学 (推定)

20

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

研究場所

    • Shanghai Municipality
      • Shanghai、Shanghai Municipality、中国、200080
        • Shanghai General Hospital

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人

健康ボランティアの受け入れ

はい

説明

Inclusion Criteria:

  • Voluntarily agrees to participate in the study and provides written informed consent.
  • Has previously worn contact lenses.
  • Has no ocular disease other than refractive error.
  • Central corneal thickness between 540 and 560 μm, inclusive.
  • Corneal curvature between 42 and 44 D, inclusive.

Exclusion Criteria:

  • Unable to tolerate the hydrogel-based wearable dynamic intraocular pressure sensor.
  • Pregnant or breastfeeding.
  • History of allergy to relevant medical materials or known hypersensitivity to materials used in the investigational device.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:他の
  • 割り当て:なし
  • 介入モデル:単一グループの割り当て
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
実験的:Hydrogel-Based Wearable Dynamic Intraocular Pressure Sensor

Participants will undergo a single-arm evaluation of a hydrogel-based wearable dynamic intraocular pressure sensor (CLS). After 2 hours of fasting from food and water, baseline ocular safety examinations will be performed. Intraocular pressure will first be measured using non-contact tonometry (NCT) and Goldmann applanation tonometry (GAT). Participants will then wear the CLS and undergo a 10-minute adaptation period before the first sensor signal is recorded.

Participants will drink 1 L of water within 5 minutes. At 10-15 minutes after completion of water intake, a second sensor signal will be recorded, followed by CLS removal and repeat GAT and NCT measurements. After an interval of at least 45 minutes, NCT and GAT will be repeated, the CLS will be worn again for a 10-minute adaptation period, and a third sensor signal will be recorded. After completion of the measurement procedure, the CLS will be removed and ocular safety examinations will be repeated to evaluate changes associate

The investigational device is a wearable hydrogel-based contact lens sensor designed to record electrical signals associated with changes in intraocular pressure. The CLS is worn on the study eye and allowed to stabilize for 10 minutes before signal acquisition. Sensor signals are obtained at three predefined measurement points and compared with Goldmann applanation tonometry measurements to assess measurement accuracy.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Absolute Error of CLS-Predicted Intraocular Pressure Compared With Goldmann Applanation Tonometry
時間枠:Day 1, at the third validation measurement
The first two paired measurements of the contact lens sensor (CLS) signal and Goldmann applanation tonometry (GAT) intraocular pressure will be used to establish an individualized linear calibration equation for each participant. The third CLS signal will be converted to a predicted intraocular pressure using the individualized calibration equation. Absolute error is defined as the absolute difference between the CLS-predicted intraocular pressure and the corresponding GAT measurement, expressed in mmHg.
Day 1, at the third validation measurement

二次結果の測定

結果測定
メジャーの説明
時間枠
Agreement Between CLS-Predicted Intraocular Pressure and Non-Contact Tonometry
時間枠:Day 1, at the third validation measurement
At the third validation assessment, intraocular pressure predicted from the contact lens sensor (CLS) using the individualized calibration equation will be compared with the corresponding non-contact tonometry (NCT) measurement.
Day 1, at the third validation measurement
Increased incidence of corneal fluorescent staining grade
時間枠:Baseline and at the post-study ocular examination on Day 1
Corneal fluorescence staining grading (National Eye Institute (NEI) standards) The cornea is divided into five regions (central, top, and above).Square, inferior, nasal side, temporal side), each area scores 0-3 points (0 = unstained, 1 = sparse dots, 2 = dense dots, 3 = fused or patchy)
Baseline and at the post-study ocular examination on Day 1
Conjunctival congestion score
時間枠:Baseline and at the post-study ocular examination on Day 1
The Ora Calibra® scale was used to measure conjunctival redness in each eye. Each eye will be rated on a scale from 0 to 4, with 0 being best and 4 being the worst.
Baseline and at the post-study ocular examination on Day 1
Change From Baseline in Tear Break-Up Time After CLS Wear
時間枠:Baseline and at the post-study ocular examination on Day 1
Tear break-up time (TBUT) will be measured before and after CLS wear. After blinking several times, the participant will keep the eye open while looking straight ahead, and the time until the first dry spot appears in the tear film will be recorded in seconds.
Baseline and at the post-study ocular examination on Day 1
Change From Baseline in Best-Corrected Visual Acuity After CLS Wear
時間枠:Baseline and at the post-study ocular examination on Day 1
Best-corrected visual acuity (BCVA) will be assessed before and after CLS wear. Change from baseline will be calculated by comparing the post-study BCVA with the baseline BCVA.
Baseline and at the post-study ocular examination on Day 1
CLDEQ-8-Based Immediate Ocular Tolerability Questionnaire
時間枠:Immediately after completion of CLS wear on Day 1

Immediate ocular tolerability during wear of the investigational contact lens sensor (CLS) will be assessed using a study-specific questionnaire adapted from the Contact Lens Dry Eye Questionnaire-8 (CLDEQ-8).

The questionnaire contains eight items assessing: frequency and intensity of ocular discomfort, frequency and intensity of ocular dryness, frequency and intensity of fluctuating or blurred vision, frequency of wanting to close the eye because of discomfort, and the desire to remove the CLS because of discomfort.

Frequency items are scored from 0 to 4, intensity items from 0 to 5, and the item assessing the desire to remove the CLS from 1 to 6. Higher scores indicate worse ocular tolerability.

Immediately after completion of CLS wear on Day 1

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (推定)

2026年8月30日

一次修了 (推定)

2026年11月30日

研究の完了 (推定)

2027年2月18日

試験登録日

最初に提出

2026年8月12日

QC基準を満たした最初の提出物

2026年8月15日

最初の投稿 (実際)

2026年8月18日

学習記録の更新

投稿された最後の更新 (実際)

2026年8月18日

QC基準を満たした最後の更新が送信されました

2026年8月15日

最終確認日

2026年8月1日