Frequency- and Intensity-Dependent After-Effects of High-Definition Transcranial Alternating Current Stimulation on Resting-State Electroencephalography
2026年8月29日 更新者:Haifeng Jiang、Shanghai Mental Health Center
Frequency- and Intensity-Dependent After-Effects of High-Definition Transcranial Alternating Current Stimulation on Resting-State Electroencephalography in Patients With Auditory Hallucinations and Healthy Controls
This study aims to investigate the after-effects of high-definition transcranial alternating current stimulation (HD-tACS) with varying parameters on resting-state brain activity in patients with schizophrenia experiencing auditory hallucinations.
調査の概要
状態
完了
研究の種類
介入
入学 (実際)
36
段階
- 適用できない
連絡先と場所
このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。
研究場所
-
-
-
Fuyang、中国
- Fuyang Mental Heath Center
-
-
参加基準
研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。
適格基準
就学可能な年齢
- 大人
- 高齢者
健康ボランティアの受け入れ
はい
説明
Inclusion Criteria:
- Age 18 to 65 years;
- Meet the diagnostic criteria for schizophrenia according to the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5);
- Adequate verbal communication skills;
- At least one auditory hallucination episode within the past week;
- Willing to participate in the study and able to complete all trial procedures.
Exclusion Criteria:
- History of neurological disorders, severe physical illness, traumatic brain injury, or craniotomy;
- History of epileptic seizures or other neuropsychiatric disorders;
- At risk for suicide, self-injury, or impulsive behavior.
研究計画
このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:クロスオーバー割り当て
- マスキング:ダブル
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:0.4mA-10Hz HD-tACS
For 0.4mA-10Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
実験的:0.4mA-20Hz HD-tACS
For 0.4mA-20Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 20 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
実験的:0.4mA-40Hz HD-tACS
For 0.4mA-40Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 20 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
実験的:0.4mA-140Hz HD-tACS
For 0.4mA-140Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
実験的:1mA-10Hz HD-tACS
For 1mA-10Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
実験的:1mA-20Hz HD-tACS
For 1mA-20Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
実験的:1mA-40Hz HD-tACS
For 1mA-40Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
実験的:1mA-140Hz HD-tACS
For 1mA-140Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
実験的:2mA-10Hz HD-tACS
For 2mA-10Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
実験的:2mA-20Hz HD-tACS
For 2mA-20Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
実験的:2mA-40Hz HD-tACS
For 2mA-40Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
実験的:2mA-140Hz HD-tACS
For 2mA-140Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
実験的:sham HD-tACS
For sham HD-tACS, we will stimulate the personalized left or right temporal lobe channel using sham HD-tACS pattern.
|
The sham intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
To mimic the sensory experience of active stimulation, the sham condition includes a 10-second ramp-up and a 5-second ramp-down period at 0.4 mA and 140 Hz, with no current delivered during the intervening 90-second period.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Beta2-band EEG power at the stimulation site
時間枠:180-second recording after each 90-second stimulation
|
Changes in EEG power(dB) in beta2 band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Alpha-band EEG power at the stimulation site
時間枠:180-second recording after each 90-second stimulation
|
Changes in EEG power(dB) in alpha band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Delta-band EEG power at the stimulation site
時間枠:180-second recording after each 90-second stimulation
|
Changes in EEG power(dB) in delta band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Theta-band EEG power at the stimulation site
時間枠:180-second recording after each 90-second stimulation
|
Changes in EEG power(dB) in theta band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Gamma-band EEG power at the stimulation site
時間枠:180-second recording after each 90-second stimulation
|
Changes in EEG power(dB) in gamma band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Beta2-band functional connectivity measured by EEG wPLI
時間枠:180-second recording after each 90-second stimulation
|
Beta2-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Alpha-band functional connectivity measured by EEG wPLI
時間枠:180-second recording after each 90-second stimulation
|
Alpha-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Delta-band functional connectivity measured by EEG wPLI
時間枠:180-second recording after each 90-second stimulation
|
Delta-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Theta-band functional connectivity measured by EEG wPLI
時間枠:180-second recording after each 90-second stimulation
|
Theta-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Gamma-band functional connectivity measured by EEG wPLI
時間枠:180-second recording after each 90-second stimulation
|
Gamma-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
協力者と研究者
ここでは、この調査に関係する人々や組織を見つけることができます。
研究記録日
これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。
主要日程の研究
研究開始 (実際)
2025年12月5日
一次修了 (実際)
2026年2月11日
研究の完了 (実際)
2026年2月15日
試験登録日
最初に提出
2026年7月1日
QC基準を満たした最初の提出物
2026年8月29日
最初の投稿 (実際)
2026年9月1日
学習記録の更新
投稿された最後の更新 (実際)
2026年9月1日
QC基準を満たした最後の更新が送信されました
2026年8月29日
最終確認日
2026年8月1日
詳しくは
本研究に関する用語
その他の研究ID番号
- HFJiang-006
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
いいえ
IPD プランの説明
Individual participant data will not be made publicly available because of privacy and confidentiality considerations related to the collection of electrophysiological data from human participants.
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
いいえ
米国FDA規制機器製品の研究
いいえ
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。