Tato stránka byla automaticky přeložena a přesnost překladu není zaručena. Podívejte se prosím na anglická verze pro zdrojový text.

Frequency- and Intensity-Dependent After-Effects of High-Definition Transcranial Alternating Current Stimulation on Resting-State Electroencephalography

29. srpna 2026 aktualizováno: Haifeng Jiang, Shanghai Mental Health Center

Frequency- and Intensity-Dependent After-Effects of High-Definition Transcranial Alternating Current Stimulation on Resting-State Electroencephalography in Patients With Auditory Hallucinations and Healthy Controls

This study aims to investigate the after-effects of high-definition transcranial alternating current stimulation (HD-tACS) with varying parameters on resting-state brain activity in patients with schizophrenia experiencing auditory hallucinations.

Přehled studie

Typ studie

Intervenční

Zápis (Aktuální)

36

Fáze

  • Nelze použít

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní místa

      • Fuyang, Čína
        • Fuyang Mental Heath Center

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

  • Dospělý
  • Starší dospělý

Přijímá zdravé dobrovolníky

Ano

Popis

Inclusion Criteria:

  • Age 18 to 65 years;
  • Meet the diagnostic criteria for schizophrenia according to the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5);
  • Adequate verbal communication skills;
  • At least one auditory hallucination episode within the past week;
  • Willing to participate in the study and able to complete all trial procedures.

Exclusion Criteria:

  • History of neurological disorders, severe physical illness, traumatic brain injury, or craniotomy;
  • History of epileptic seizures or other neuropsychiatric disorders;
  • At risk for suicide, self-injury, or impulsive behavior.

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Primární účel: Léčba
  • Přidělení: Randomizované
  • Intervenční model: Crossover Assignment
  • Maskování: Dvojnásobek

Zbraně a zásahy

Skupina účastníků / Arm
Intervence / Léčba
Experimentální: 0.4mA-10Hz HD-tACS
For 0.4mA-10Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentální: 0.4mA-20Hz HD-tACS
For 0.4mA-20Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 20 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentální: 0.4mA-40Hz HD-tACS
For 0.4mA-40Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 20 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentální: 0.4mA-140Hz HD-tACS
For 0.4mA-140Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentální: 1mA-10Hz HD-tACS
For 1mA-10Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentální: 1mA-20Hz HD-tACS
For 1mA-20Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentální: 1mA-40Hz HD-tACS
For 1mA-40Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentální: 1mA-140Hz HD-tACS
For 1mA-140Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentální: 2mA-10Hz HD-tACS
For 2mA-10Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentální: 2mA-20Hz HD-tACS
For 2mA-20Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentální: 2mA-40Hz HD-tACS
For 2mA-40Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentální: 2mA-140Hz HD-tACS
For 2mA-140Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentální: sham HD-tACS
For sham HD-tACS, we will stimulate the personalized left or right temporal lobe channel using sham HD-tACS pattern.
The sham intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. To mimic the sensory experience of active stimulation, the sham condition includes a 10-second ramp-up and a 5-second ramp-down period at 0.4 mA and 140 Hz, with no current delivered during the intervening 90-second period.

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Beta2-band EEG power at the stimulation site
Časové okno: 180-second recording after each 90-second stimulation
Changes in EEG power(dB) in beta2 band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation

Sekundární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Alpha-band EEG power at the stimulation site
Časové okno: 180-second recording after each 90-second stimulation
Changes in EEG power(dB) in alpha band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Delta-band EEG power at the stimulation site
Časové okno: 180-second recording after each 90-second stimulation
Changes in EEG power(dB) in delta band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Theta-band EEG power at the stimulation site
Časové okno: 180-second recording after each 90-second stimulation
Changes in EEG power(dB) in theta band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Gamma-band EEG power at the stimulation site
Časové okno: 180-second recording after each 90-second stimulation
Changes in EEG power(dB) in gamma band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Beta2-band functional connectivity measured by EEG wPLI
Časové okno: 180-second recording after each 90-second stimulation
Beta2-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Alpha-band functional connectivity measured by EEG wPLI
Časové okno: 180-second recording after each 90-second stimulation
Alpha-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Delta-band functional connectivity measured by EEG wPLI
Časové okno: 180-second recording after each 90-second stimulation
Delta-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Theta-band functional connectivity measured by EEG wPLI
Časové okno: 180-second recording after each 90-second stimulation
Theta-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Gamma-band functional connectivity measured by EEG wPLI
Časové okno: 180-second recording after each 90-second stimulation
Gamma-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Aktuální)

5. prosince 2025

Primární dokončení (Aktuální)

11. února 2026

Dokončení studie (Aktuální)

15. února 2026

Termíny zápisu do studia

První předloženo

1. července 2026

První předloženo, které splnilo kritéria kontroly kvality

29. srpna 2026

První zveřejněno (Aktuální)

1. září 2026

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

1. září 2026

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

29. srpna 2026

Naposledy ověřeno

1. srpna 2026

Více informací

Termíny související s touto studií

Další identifikační čísla studie

  • HFJiang-006

Plán pro data jednotlivých účastníků (IPD)

Plánujete sdílet data jednotlivých účastníků (IPD)?

NE

Popis plánu IPD

Individual participant data will not be made publicly available because of privacy and confidentiality considerations related to the collection of electrophysiological data from human participants.

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .

Předplatit