Denna sida har översatts automatiskt och översättningens korrekthet kan inte garanteras. Vänligen se engelsk version för en källtext.

Frequency- and Intensity-Dependent After-Effects of High-Definition Transcranial Alternating Current Stimulation on Resting-State Electroencephalography

29 augusti 2026 uppdaterad av: Haifeng Jiang, Shanghai Mental Health Center

Frequency- and Intensity-Dependent After-Effects of High-Definition Transcranial Alternating Current Stimulation on Resting-State Electroencephalography in Patients With Auditory Hallucinations and Healthy Controls

This study aims to investigate the after-effects of high-definition transcranial alternating current stimulation (HD-tACS) with varying parameters on resting-state brain activity in patients with schizophrenia experiencing auditory hallucinations.

Studieöversikt

Studietyp

Interventionell

Inskrivning (Faktisk)

36

Fas

  • Inte tillämpbar

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studieorter

      • Fuyang, Kina
        • Fuyang Mental Heath Center

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

  • Vuxen
  • Äldre vuxen

Tar emot friska volontärer

Ja

Beskrivning

Inclusion Criteria:

  • Age 18 to 65 years;
  • Meet the diagnostic criteria for schizophrenia according to the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5);
  • Adequate verbal communication skills;
  • At least one auditory hallucination episode within the past week;
  • Willing to participate in the study and able to complete all trial procedures.

Exclusion Criteria:

  • History of neurological disorders, severe physical illness, traumatic brain injury, or craniotomy;
  • History of epileptic seizures or other neuropsychiatric disorders;
  • At risk for suicide, self-injury, or impulsive behavior.

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

  • Primärt syfte: Behandling
  • Tilldelning: Randomiserad
  • Interventionsmodell: Crossover tilldelning
  • Maskning: Dubbel

Vapen och interventioner

Deltagargrupp / Arm
Intervention / Behandling
Experimentell: 0.4mA-10Hz HD-tACS
For 0.4mA-10Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentell: 0.4mA-20Hz HD-tACS
For 0.4mA-20Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 20 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentell: 0.4mA-40Hz HD-tACS
For 0.4mA-40Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 20 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentell: 0.4mA-140Hz HD-tACS
For 0.4mA-140Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentell: 1mA-10Hz HD-tACS
For 1mA-10Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentell: 1mA-20Hz HD-tACS
For 1mA-20Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentell: 1mA-40Hz HD-tACS
For 1mA-40Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentell: 1mA-140Hz HD-tACS
For 1mA-140Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentell: 2mA-10Hz HD-tACS
For 2mA-10Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentell: 2mA-20Hz HD-tACS
For 2mA-20Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentell: 2mA-40Hz HD-tACS
For 2mA-40Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentell: 2mA-140Hz HD-tACS
For 2mA-140Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Experimentell: sham HD-tACS
For sham HD-tACS, we will stimulate the personalized left or right temporal lobe channel using sham HD-tACS pattern.
The sham intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. To mimic the sensory experience of active stimulation, the sham condition includes a 10-second ramp-up and a 5-second ramp-down period at 0.4 mA and 140 Hz, with no current delivered during the intervening 90-second period.

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Beta2-band EEG power at the stimulation site
Tidsram: 180-second recording after each 90-second stimulation
Changes in EEG power(dB) in beta2 band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation

Sekundära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Alpha-band EEG power at the stimulation site
Tidsram: 180-second recording after each 90-second stimulation
Changes in EEG power(dB) in alpha band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Delta-band EEG power at the stimulation site
Tidsram: 180-second recording after each 90-second stimulation
Changes in EEG power(dB) in delta band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Theta-band EEG power at the stimulation site
Tidsram: 180-second recording after each 90-second stimulation
Changes in EEG power(dB) in theta band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Gamma-band EEG power at the stimulation site
Tidsram: 180-second recording after each 90-second stimulation
Changes in EEG power(dB) in gamma band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Beta2-band functional connectivity measured by EEG wPLI
Tidsram: 180-second recording after each 90-second stimulation
Beta2-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Alpha-band functional connectivity measured by EEG wPLI
Tidsram: 180-second recording after each 90-second stimulation
Alpha-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Delta-band functional connectivity measured by EEG wPLI
Tidsram: 180-second recording after each 90-second stimulation
Delta-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Theta-band functional connectivity measured by EEG wPLI
Tidsram: 180-second recording after each 90-second stimulation
Theta-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Gamma-band functional connectivity measured by EEG wPLI
Tidsram: 180-second recording after each 90-second stimulation
Gamma-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart (Faktisk)

5 december 2025

Primärt slutförande (Faktisk)

11 februari 2026

Avslutad studie (Faktisk)

15 februari 2026

Studieregistreringsdatum

Först inskickad

1 juli 2026

Först inskickad som uppfyllde QC-kriterierna

29 augusti 2026

Första postat (Faktisk)

1 september 2026

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

1 september 2026

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

29 augusti 2026

Senast verifierad

1 augusti 2026

Mer information

Termer relaterade till denna studie

Andra studie-ID-nummer

  • HFJiang-006

Plan för individuella deltagardata (IPD)

Planerar du att dela individuella deltagardata (IPD)?

NEJ

IPD-planbeskrivning

Individual participant data will not be made publicly available because of privacy and confidentiality considerations related to the collection of electrophysiological data from human participants.

Läkemedels- och apparatinformation, studiedokument

Studerar en amerikansk FDA-reglerad läkemedelsprodukt

Nej

Studerar en amerikansk FDA-reglerad produktprodukt

Nej

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Prenumerera