Denne siden ble automatisk oversatt og nøyaktigheten av oversettelsen er ikke garantert. Vennligst referer til engelsk versjon for en kildetekst.

Frequency- and Intensity-Dependent After-Effects of High-Definition Transcranial Alternating Current Stimulation on Resting-State Electroencephalography

29. august 2026 oppdatert av: Haifeng Jiang, Shanghai Mental Health Center

Frequency- and Intensity-Dependent After-Effects of High-Definition Transcranial Alternating Current Stimulation on Resting-State Electroencephalography in Patients With Auditory Hallucinations and Healthy Controls

This study aims to investigate the after-effects of high-definition transcranial alternating current stimulation (HD-tACS) with varying parameters on resting-state brain activity in patients with schizophrenia experiencing auditory hallucinations.

Studieoversikt

Studietype

Intervensjonell

Registrering (Faktiske)

36

Fase

  • Ikke aktuelt

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiesteder

      • Fuyang, Kina
        • Fuyang Mental Heath Center

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

  • Voksen
  • Eldre voksen

Tar imot friske frivillige

Ja

Beskrivelse

Inclusion Criteria:

  • Age 18 to 65 years;
  • Meet the diagnostic criteria for schizophrenia according to the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5);
  • Adequate verbal communication skills;
  • At least one auditory hallucination episode within the past week;
  • Willing to participate in the study and able to complete all trial procedures.

Exclusion Criteria:

  • History of neurological disorders, severe physical illness, traumatic brain injury, or craniotomy;
  • History of epileptic seizures or other neuropsychiatric disorders;
  • At risk for suicide, self-injury, or impulsive behavior.

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

  • Primært formål: Behandling
  • Tildeling: Randomisert
  • Intervensjonsmodell: Crossover-oppdrag
  • Masking: Dobbelt

Våpen og intervensjoner

Deltakergruppe / Arm
Intervensjon / Behandling
Eksperimentell: 0.4mA-10Hz HD-tACS
For 0.4mA-10Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Eksperimentell: 0.4mA-20Hz HD-tACS
For 0.4mA-20Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 20 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Eksperimentell: 0.4mA-40Hz HD-tACS
For 0.4mA-40Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 20 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Eksperimentell: 0.4mA-140Hz HD-tACS
For 0.4mA-140Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Eksperimentell: 1mA-10Hz HD-tACS
For 1mA-10Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Eksperimentell: 1mA-20Hz HD-tACS
For 1mA-20Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Eksperimentell: 1mA-40Hz HD-tACS
For 1mA-40Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Eksperimentell: 1mA-140Hz HD-tACS
For 1mA-140Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Eksperimentell: 2mA-10Hz HD-tACS
For 2mA-10Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Eksperimentell: 2mA-20Hz HD-tACS
For 2mA-20Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Eksperimentell: 2mA-40Hz HD-tACS
For 2mA-40Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Eksperimentell: 2mA-140Hz HD-tACS
For 2mA-140Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol. A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition. The stimulus waveform is sinusoidal. Stimulation is delivered using saline-soaked sponge electrodes. Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
Eksperimentell: sham HD-tACS
For sham HD-tACS, we will stimulate the personalized left or right temporal lobe channel using sham HD-tACS pattern.
The sham intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe. The return electrodes deliver one-quarter of the central electrode current with opposite polarity. To mimic the sensory experience of active stimulation, the sham condition includes a 10-second ramp-up and a 5-second ramp-down period at 0.4 mA and 140 Hz, with no current delivered during the intervening 90-second period.

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Beta2-band EEG power at the stimulation site
Tidsramme: 180-second recording after each 90-second stimulation
Changes in EEG power(dB) in beta2 band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation

Sekundære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Alpha-band EEG power at the stimulation site
Tidsramme: 180-second recording after each 90-second stimulation
Changes in EEG power(dB) in alpha band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Delta-band EEG power at the stimulation site
Tidsramme: 180-second recording after each 90-second stimulation
Changes in EEG power(dB) in delta band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Theta-band EEG power at the stimulation site
Tidsramme: 180-second recording after each 90-second stimulation
Changes in EEG power(dB) in theta band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Gamma-band EEG power at the stimulation site
Tidsramme: 180-second recording after each 90-second stimulation
Changes in EEG power(dB) in gamma band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Beta2-band functional connectivity measured by EEG wPLI
Tidsramme: 180-second recording after each 90-second stimulation
Beta2-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Alpha-band functional connectivity measured by EEG wPLI
Tidsramme: 180-second recording after each 90-second stimulation
Alpha-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Delta-band functional connectivity measured by EEG wPLI
Tidsramme: 180-second recording after each 90-second stimulation
Delta-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Theta-band functional connectivity measured by EEG wPLI
Tidsramme: 180-second recording after each 90-second stimulation
Theta-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation
Gamma-band functional connectivity measured by EEG wPLI
Tidsramme: 180-second recording after each 90-second stimulation
Gamma-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
180-second recording after each 90-second stimulation

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Faktiske)

5. desember 2025

Primær fullføring (Faktiske)

11. februar 2026

Studiet fullført (Faktiske)

15. februar 2026

Datoer for studieregistrering

Først innsendt

1. juli 2026

Først innsendt som oppfylte QC-kriteriene

29. august 2026

Først lagt ut (Faktiske)

1. september 2026

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

1. september 2026

Siste oppdatering sendt inn som oppfylte QC-kriteriene

29. august 2026

Sist bekreftet

1. august 2026

Mer informasjon

Begreper knyttet til denne studien

Andre studie-ID-numre

  • HFJiang-006

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

NEI

IPD-planbeskrivelse

Individual participant data will not be made publicly available because of privacy and confidentiality considerations related to the collection of electrophysiological data from human participants.

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .