このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Noninvasive Assessment of Intracranial Pressure Using Otoacoustic Emissions in Healthy Subjects and Glaucoma Patients (COSMO)

2026年11月20日 更新者:Fondazione G.B. Bietti, IRCCS

Noninvasive Intracranial Pressure Assessment Using Otoacoustic Emissions in Healthy Subjects and Glaucoma Patients

The COSMO study aims to investigate whether a noninvasive test based on otoacoustic emissions, which are sounds produced by the inner ear, can provide useful information about changes in intracranial pressure in people with glaucoma and healthy individuals.

Glaucoma is an eye disease that can damage the optic nerve and cause vision loss. Researchers believe that the relationship between pressure inside the eye and pressure inside the skull may play a role in glaucoma.

This study will compare measurements of distortion product otoacoustic emissions (DPOAEs) between patients with glaucoma and healthy participants. Researchers will assess how reproducible these measurements are and how they change with different body positions and changes in intraocular pressure.

Participants will undergo eye examinations and noninvasive ear measurements while assuming different body positions.

The results may help researchers better understand the relationship between intracranial pressure, intraocular pressure, and glaucoma, and evaluate the potential usefulness of otoacoustic emissions as a noninvasive assessment method.

調査の概要

詳細な説明

COSMO is a single-center, prospective, interventional clinical study with a medical device designed to investigate the reproducibility of distortion product otoacoustic emission (DPOAE) phase measurements in patients with glaucoma and healthy subjects.

The study is based on the hypothesis that changes in intracranial pressure may influence otoacoustic emissions and that the relationship between intracranial pressure and intraocular pressure (IOP) may be relevant to glaucoma.

**Primary Objective**

To assess the reproducibility of DPOAE phase measurements and compare their repeatability between patients with glaucoma and healthy subjects.

**Secondary Objectives**

  • To compare changes in DPOAE phase and intraocular pressure (ΔIOP) between glaucoma patients and healthy subjects.
  • To investigate the relationship between DPOAE phase changes and intraocular pressure changes across different body positions.
  • To explore the influence of central corneal thickness and corneal hysteresis on these relationships.

**Study Procedures**

Following written informed consent, participants will undergo a screening assessment to confirm eligibility.

Screening examinations will include:

  • Best-corrected visual acuity assessment.
  • Anterior segment biomicroscopy.
  • Visual field testing in glaucoma patients.
  • Optical coherence tomography (OCT) of the optic nerve head and macula.
  • Intraocular pressure measurement.
  • Fundus examination.
  • Otoscopy to assess ear canal patency.

Eligible participants will undergo additional measurements of central corneal thickness, corneal hysteresis, and optic nerve ultrasonography.

Intraocular pressure and DPOAE measurements will be assessed in different body positions, including sitting, supine, semi-reclined, and prone positions. The order of body positions will be randomly assigned using a computer-generated sequence.

Participants will maintain each assigned position for at least 30 minutes before the measurements.

DPOAEs will be recorded using a portable measurement system with a probe placed in the ear canal. Measurements will be performed over a frequency range of 500 to 4000 Hz.

In the sitting position, DPOAE measurements will be repeated after removing and reinserting the ear probe to evaluate test-retest repeatability.

**Outcome Assessment**

The primary endpoint is the repeatability of DPOAE phase measurements in glaucoma patients and healthy subjects.

Secondary assessments will investigate differences and correlations between DPOAE phase changes and intraocular pressure changes across different body positions, including their relationships with central corneal thickness and corneal hysteresis.

All study assessments will be completed during a single study visit consisting of screening and testing procedures. No additional study-specific follow-up visits are planned.

The findings may contribute to the development of noninvasive methods for investigating pressure-related mechanisms in glaucoma.

研究の種類

介入

入学 (推定)

112

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

研究連絡先のバックアップ

研究場所

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

50年~70年 (大人、高齢者)

健康ボランティアの受け入れ

はい

受講資格のある性別

全て

説明

**Inclusion Criteria:**

General inclusion criteria (all participants):

  • Age between 50 and 70 years.
  • Central corneal thickness between 500 and 600 µm.
  • Patent ear canal at otoscopy.
  • Written informed consent freely provided before the start of any study procedures.
  • Ability to understand and willingness to follow study instructions and likely to complete all required study visits and procedures.

Additional inclusion criteria for healthy subjects:

  • No eye disease.
  • No family history of glaucoma.

Additional inclusion criteria for glaucoma patients:

  • Clinical diagnosis of primary open-angle glaucoma, normal-tension glaucoma, pseudoexfoliative glaucoma, or pigmentary glaucoma.
  • Reproducible visual field defect on the Humphrey Field Analyzer (HFA) 24-2 test compatible with glaucoma, defined by the presence of a cluster of three or more non-continuous points in the pattern deviation plot with a probability of occurrence in the normal population of less than 5%, including at least one point with p < 1%, a pattern standard deviation with p < 5%, or a Glaucoma Hemifield Test result outside normal limits.
  • Optic nerve head (ONH) abnormalities compatible with glaucoma, including generalized or focal enlargement of the optic cup, thinning of the neuroretinal rim, cup-to-disc ratio asymmetry greater than 0.2 between eyes, or retinal nerve fiber layer loss.

**Exclusion Criteria:**

General exclusion criteria (all participants):

  • History of inner or middle ear disease.
  • History of cerebral diseases that may increase intracranial pressure (ICP), including neoplastic, ischemic, toxic, or infectious causes of cerebral edema, hydrocephalus, obstruction of major venous sinuses, vascular malformations, or idiopathic intracranial hypertension.
  • Systemic treatment with medications known to affect ICP, including corticosteroids, nitroprusside, nitroglycerin, hydralazine, nicardipine, topiramate, and loop diuretics (e.g., furosemide).
  • Non-recordable distortion product otoacoustic emissions (DPOAEs).
  • Uncontrolled blood pressure, with or without systemic treatment.
  • Retinal or optic nerve head diseases other than glaucoma, as assessed by optical coherence tomography (OCT) scans of the macula, optic nerve head, and retinal nerve fiber layer (RNFL).
  • Phacoemulsification or glaucoma filtering surgery within the previous 6 months.

Additional exclusion criterion for healthy subjects:

- Intraocular pressure (IOP) greater than 21 mmHg.

Additional exclusion criterion for glaucoma patients:

- Oral acetazolamide treatment as part of the therapeutic regimen, due to its potential effect on intracranial pressure.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:診断
  • 割り当て:非ランダム化
  • 介入モデル:並列代入
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
実験的:Glaucoma Patients

Patients diagnosed with glaucoma who will undergo noninvasive distortion product otoacoustic emission (DPOAE) measurements and intraocular pressure assessments in different body positions. DPOAE phase measurements will be used to evaluate test-retest repeatability and investigate the relationship between otoacoustic emission changes and intraocular pressure variations.

Noninvasive measurement of distortion product otoacoustic emissions (DPOAEs) using the Titan System with IMP440 Impedance System version 3.7 (Interacoustics A/S, Denmark).

DPOAE phase measurements will be performed in different body positions (sitting at 90°, semi-reclined at 135°, supine at 180°, and prone at 0°), with the order randomly assigned using a computer-generated sequence.

Participants will maintain each position for at least 30 minutes before DPOAE and intraocular pressure measurements. DPOAEs will be recorded over a frequency range of 500 to 4000 Hz.

In the sitting position, DPOAE measurements will be repeated three times to assess test-retest repeatability.

実験的:Healthy Subjects

Healthy participants without glaucoma who will undergo the same noninvasive distortion product otoacoustic emission (DPOAE) measurements and intraocular pressure assessments in different body positions. Measurements will be used to evaluate test-retest repeatability and provide comparative data for the glaucoma group.

Noninvasive measurement of distortion product otoacoustic emissions (DPOAEs) using the Titan System with IMP440 Impedance System version 3.7 (Interacoustics A/S, Denmark).

DPOAE phase measurements will be performed in different body positions (sitting at 90°, semi-reclined at 135°, supine at 180°, and prone at 0°), with the order randomly assigned using a computer-generated sequence.

Participants will maintain each position for at least 30 minutes before DPOAE and intraocular pressure measurements. DPOAEs will be recorded over a frequency range of 500 to 4000 Hz.

In the sitting position, DPOAE measurements will be repeated three times to assess test-retest repeatability.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Repeatability of Distortion Product Otoacoustic Emission (DPOAE) Phase Measurements
時間枠:During the single study visit (Day 1)

Assessment of the test-retest repeatability of distortion product otoacoustic emission (DPOAE) phase measurements in glaucoma patients and healthy subjects. DPOAE phase will be measured repeatedly in the sitting position (90°), with removal and reinsertion of the ear probe between measurements. Repeatability will be quantified as the standard deviation of differences between repeated measurements, expressed in degrees of phase.

During the single study visit (Day 1)

二次結果の測定

結果測定
メジャーの説明
時間枠
Differences in DPOAE Phase Changes and Intraocular Pressure Changes Between Study Groups
時間枠:During the single study visit (Day 1)

Comparison of distortion product otoacoustic emission (DPOAE) phase changes, expressed in degrees and averaged over three octave bands (0.5-1, 1-2, and 2-4 kHz), and mean changes in intraocular pressure (ΔIOP), expressed in mmHg, between glaucoma patients and healthy subjects across different body positions (90°, 135°, 180°, and 0°).

During the single study visit (Day 1)
Association Between DPOAE Phase Changes, Intraocular Pressure Changes, and Corneal Parameters
時間枠:During the single study visit (Day 1)

Assessment of the relationship between distortion product otoacoustic emission (DPOAE) phase changes (degrees) and intraocular pressure changes (ΔIOP, mmHg) across different body positions, considering central corneal thickness (µm) and corneal hysteresis (mmHg). Associations will be evaluated using Pearson or Spearman correlation coefficients and mixed-effects models.

During the single study visit (Day 1)

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2026年11月11日

一次修了 (推定)

2027年11月11日

研究の完了 (推定)

2027年11月11日

試験登録日

最初に提出

2026年11月20日

QC基準を満たした最初の提出物

2026年11月20日

最初の投稿 (実際)

2026年11月27日

学習記録の更新

投稿された最後の更新 (実際)

2026年11月27日

QC基準を満たした最後の更新が送信されました

2026年11月20日

最終確認日

2026年11月1日

詳しくは

本研究に関する用語

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

未定

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する