Noninvasive Assessment of Intracranial Pressure Using Otoacoustic Emissions in Healthy Subjects and Glaucoma Patients (COSMO)

20. listopadu 2026 aktualizováno: Fondazione G.B. Bietti, IRCCS

Noninvasive Intracranial Pressure Assessment Using Otoacoustic Emissions in Healthy Subjects and Glaucoma Patients

The COSMO study aims to investigate whether a noninvasive test based on otoacoustic emissions, which are sounds produced by the inner ear, can provide useful information about changes in intracranial pressure in people with glaucoma and healthy individuals.

Glaucoma is an eye disease that can damage the optic nerve and cause vision loss. Researchers believe that the relationship between pressure inside the eye and pressure inside the skull may play a role in glaucoma.

This study will compare measurements of distortion product otoacoustic emissions (DPOAEs) between patients with glaucoma and healthy participants. Researchers will assess how reproducible these measurements are and how they change with different body positions and changes in intraocular pressure.

Participants will undergo eye examinations and noninvasive ear measurements while assuming different body positions.

The results may help researchers better understand the relationship between intracranial pressure, intraocular pressure, and glaucoma, and evaluate the potential usefulness of otoacoustic emissions as a noninvasive assessment method.

Přehled studie

Postavení

Nábor

Podmínky

Detailní popis

COSMO is a single-center, prospective, interventional clinical study with a medical device designed to investigate the reproducibility of distortion product otoacoustic emission (DPOAE) phase measurements in patients with glaucoma and healthy subjects.

The study is based on the hypothesis that changes in intracranial pressure may influence otoacoustic emissions and that the relationship between intracranial pressure and intraocular pressure (IOP) may be relevant to glaucoma.

**Primary Objective**

To assess the reproducibility of DPOAE phase measurements and compare their repeatability between patients with glaucoma and healthy subjects.

**Secondary Objectives**

  • To compare changes in DPOAE phase and intraocular pressure (ΔIOP) between glaucoma patients and healthy subjects.
  • To investigate the relationship between DPOAE phase changes and intraocular pressure changes across different body positions.
  • To explore the influence of central corneal thickness and corneal hysteresis on these relationships.

**Study Procedures**

Following written informed consent, participants will undergo a screening assessment to confirm eligibility.

Screening examinations will include:

  • Best-corrected visual acuity assessment.
  • Anterior segment biomicroscopy.
  • Visual field testing in glaucoma patients.
  • Optical coherence tomography (OCT) of the optic nerve head and macula.
  • Intraocular pressure measurement.
  • Fundus examination.
  • Otoscopy to assess ear canal patency.

Eligible participants will undergo additional measurements of central corneal thickness, corneal hysteresis, and optic nerve ultrasonography.

Intraocular pressure and DPOAE measurements will be assessed in different body positions, including sitting, supine, semi-reclined, and prone positions. The order of body positions will be randomly assigned using a computer-generated sequence.

Participants will maintain each assigned position for at least 30 minutes before the measurements.

DPOAEs will be recorded using a portable measurement system with a probe placed in the ear canal. Measurements will be performed over a frequency range of 500 to 4000 Hz.

In the sitting position, DPOAE measurements will be repeated after removing and reinserting the ear probe to evaluate test-retest repeatability.

**Outcome Assessment**

The primary endpoint is the repeatability of DPOAE phase measurements in glaucoma patients and healthy subjects.

Secondary assessments will investigate differences and correlations between DPOAE phase changes and intraocular pressure changes across different body positions, including their relationships with central corneal thickness and corneal hysteresis.

All study assessments will be completed during a single study visit consisting of screening and testing procedures. No additional study-specific follow-up visits are planned.

The findings may contribute to the development of noninvasive methods for investigating pressure-related mechanisms in glaucoma.

Typ studie

Intervenční

Zápis (Odhadovaný)

112

Fáze

  • Nelze použít

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní kontakt

Studijní záloha kontaktů

Studijní místa

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

50 let až 70 let (Dospělý, Starší dospělý)

Přijímá zdravé dobrovolníky

Ano

Pohlaví způsobilá ke studiu

Všechno

Popis

**Inclusion Criteria:**

General inclusion criteria (all participants):

  • Age between 50 and 70 years.
  • Central corneal thickness between 500 and 600 µm.
  • Patent ear canal at otoscopy.
  • Written informed consent freely provided before the start of any study procedures.
  • Ability to understand and willingness to follow study instructions and likely to complete all required study visits and procedures.

Additional inclusion criteria for healthy subjects:

  • No eye disease.
  • No family history of glaucoma.

Additional inclusion criteria for glaucoma patients:

  • Clinical diagnosis of primary open-angle glaucoma, normal-tension glaucoma, pseudoexfoliative glaucoma, or pigmentary glaucoma.
  • Reproducible visual field defect on the Humphrey Field Analyzer (HFA) 24-2 test compatible with glaucoma, defined by the presence of a cluster of three or more non-continuous points in the pattern deviation plot with a probability of occurrence in the normal population of less than 5%, including at least one point with p < 1%, a pattern standard deviation with p < 5%, or a Glaucoma Hemifield Test result outside normal limits.
  • Optic nerve head (ONH) abnormalities compatible with glaucoma, including generalized or focal enlargement of the optic cup, thinning of the neuroretinal rim, cup-to-disc ratio asymmetry greater than 0.2 between eyes, or retinal nerve fiber layer loss.

**Exclusion Criteria:**

General exclusion criteria (all participants):

  • History of inner or middle ear disease.
  • History of cerebral diseases that may increase intracranial pressure (ICP), including neoplastic, ischemic, toxic, or infectious causes of cerebral edema, hydrocephalus, obstruction of major venous sinuses, vascular malformations, or idiopathic intracranial hypertension.
  • Systemic treatment with medications known to affect ICP, including corticosteroids, nitroprusside, nitroglycerin, hydralazine, nicardipine, topiramate, and loop diuretics (e.g., furosemide).
  • Non-recordable distortion product otoacoustic emissions (DPOAEs).
  • Uncontrolled blood pressure, with or without systemic treatment.
  • Retinal or optic nerve head diseases other than glaucoma, as assessed by optical coherence tomography (OCT) scans of the macula, optic nerve head, and retinal nerve fiber layer (RNFL).
  • Phacoemulsification or glaucoma filtering surgery within the previous 6 months.

Additional exclusion criterion for healthy subjects:

- Intraocular pressure (IOP) greater than 21 mmHg.

Additional exclusion criterion for glaucoma patients:

- Oral acetazolamide treatment as part of the therapeutic regimen, due to its potential effect on intracranial pressure.

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Primární účel: Diagnostický
  • Přidělení: Nerandomizované
  • Intervenční model: Paralelní přiřazení
  • Maskování: Žádné (otevřený štítek)

Zbraně a zásahy

Skupina účastníků / Arm
Intervence / Léčba
Experimentální: Glaucoma Patients

Patients diagnosed with glaucoma who will undergo noninvasive distortion product otoacoustic emission (DPOAE) measurements and intraocular pressure assessments in different body positions. DPOAE phase measurements will be used to evaluate test-retest repeatability and investigate the relationship between otoacoustic emission changes and intraocular pressure variations.

Noninvasive measurement of distortion product otoacoustic emissions (DPOAEs) using the Titan System with IMP440 Impedance System version 3.7 (Interacoustics A/S, Denmark).

DPOAE phase measurements will be performed in different body positions (sitting at 90°, semi-reclined at 135°, supine at 180°, and prone at 0°), with the order randomly assigned using a computer-generated sequence.

Participants will maintain each position for at least 30 minutes before DPOAE and intraocular pressure measurements. DPOAEs will be recorded over a frequency range of 500 to 4000 Hz.

In the sitting position, DPOAE measurements will be repeated three times to assess test-retest repeatability.

Experimentální: Healthy Subjects

Healthy participants without glaucoma who will undergo the same noninvasive distortion product otoacoustic emission (DPOAE) measurements and intraocular pressure assessments in different body positions. Measurements will be used to evaluate test-retest repeatability and provide comparative data for the glaucoma group.

Noninvasive measurement of distortion product otoacoustic emissions (DPOAEs) using the Titan System with IMP440 Impedance System version 3.7 (Interacoustics A/S, Denmark).

DPOAE phase measurements will be performed in different body positions (sitting at 90°, semi-reclined at 135°, supine at 180°, and prone at 0°), with the order randomly assigned using a computer-generated sequence.

Participants will maintain each position for at least 30 minutes before DPOAE and intraocular pressure measurements. DPOAEs will be recorded over a frequency range of 500 to 4000 Hz.

In the sitting position, DPOAE measurements will be repeated three times to assess test-retest repeatability.

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Repeatability of Distortion Product Otoacoustic Emission (DPOAE) Phase Measurements
Časové okno: During the single study visit (Day 1)

Assessment of the test-retest repeatability of distortion product otoacoustic emission (DPOAE) phase measurements in glaucoma patients and healthy subjects. DPOAE phase will be measured repeatedly in the sitting position (90°), with removal and reinsertion of the ear probe between measurements. Repeatability will be quantified as the standard deviation of differences between repeated measurements, expressed in degrees of phase.

During the single study visit (Day 1)

Sekundární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Differences in DPOAE Phase Changes and Intraocular Pressure Changes Between Study Groups
Časové okno: During the single study visit (Day 1)

Comparison of distortion product otoacoustic emission (DPOAE) phase changes, expressed in degrees and averaged over three octave bands (0.5-1, 1-2, and 2-4 kHz), and mean changes in intraocular pressure (ΔIOP), expressed in mmHg, between glaucoma patients and healthy subjects across different body positions (90°, 135°, 180°, and 0°).

During the single study visit (Day 1)
Association Between DPOAE Phase Changes, Intraocular Pressure Changes, and Corneal Parameters
Časové okno: During the single study visit (Day 1)

Assessment of the relationship between distortion product otoacoustic emission (DPOAE) phase changes (degrees) and intraocular pressure changes (ΔIOP, mmHg) across different body positions, considering central corneal thickness (µm) and corneal hysteresis (mmHg). Associations will be evaluated using Pearson or Spearman correlation coefficients and mixed-effects models.

During the single study visit (Day 1)

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Aktuální)

11. listopadu 2026

Primární dokončení (Odhadovaný)

11. listopadu 2027

Dokončení studie (Odhadovaný)

11. listopadu 2027

Termíny zápisu do studia

První předloženo

20. listopadu 2026

První předloženo, které splnilo kritéria kontroly kvality

20. listopadu 2026

První zveřejněno (Aktuální)

27. listopadu 2026

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

27. listopadu 2026

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

20. listopadu 2026

Naposledy ověřeno

1. listopadu 2026

Více informací

Termíny související s touto studií

Plán pro data jednotlivých účastníků (IPD)

Plánujete sdílet data jednotlivých účastníků (IPD)?

NEROZHODNÝ

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .