Tämä sivu käännettiin automaattisesti, eikä käännösten tarkkuutta voida taata. Katso englanninkielinen versio lähdetekstiä varten.

Noninvasive Assessment of Intracranial Pressure Using Otoacoustic Emissions in Healthy Subjects and Glaucoma Patients (COSMO)

perjantai 20. marraskuuta 2026 päivittänyt: Fondazione G.B. Bietti, IRCCS

Noninvasive Intracranial Pressure Assessment Using Otoacoustic Emissions in Healthy Subjects and Glaucoma Patients

The COSMO study aims to investigate whether a noninvasive test based on otoacoustic emissions, which are sounds produced by the inner ear, can provide useful information about changes in intracranial pressure in people with glaucoma and healthy individuals.

Glaucoma is an eye disease that can damage the optic nerve and cause vision loss. Researchers believe that the relationship between pressure inside the eye and pressure inside the skull may play a role in glaucoma.

This study will compare measurements of distortion product otoacoustic emissions (DPOAEs) between patients with glaucoma and healthy participants. Researchers will assess how reproducible these measurements are and how they change with different body positions and changes in intraocular pressure.

Participants will undergo eye examinations and noninvasive ear measurements while assuming different body positions.

The results may help researchers better understand the relationship between intracranial pressure, intraocular pressure, and glaucoma, and evaluate the potential usefulness of otoacoustic emissions as a noninvasive assessment method.

Tutkimuksen yleiskatsaus

Tila

Rekrytointi

Ehdot

Yksityiskohtainen kuvaus

COSMO is a single-center, prospective, interventional clinical study with a medical device designed to investigate the reproducibility of distortion product otoacoustic emission (DPOAE) phase measurements in patients with glaucoma and healthy subjects.

The study is based on the hypothesis that changes in intracranial pressure may influence otoacoustic emissions and that the relationship between intracranial pressure and intraocular pressure (IOP) may be relevant to glaucoma.

**Primary Objective**

To assess the reproducibility of DPOAE phase measurements and compare their repeatability between patients with glaucoma and healthy subjects.

**Secondary Objectives**

  • To compare changes in DPOAE phase and intraocular pressure (ΔIOP) between glaucoma patients and healthy subjects.
  • To investigate the relationship between DPOAE phase changes and intraocular pressure changes across different body positions.
  • To explore the influence of central corneal thickness and corneal hysteresis on these relationships.

**Study Procedures**

Following written informed consent, participants will undergo a screening assessment to confirm eligibility.

Screening examinations will include:

  • Best-corrected visual acuity assessment.
  • Anterior segment biomicroscopy.
  • Visual field testing in glaucoma patients.
  • Optical coherence tomography (OCT) of the optic nerve head and macula.
  • Intraocular pressure measurement.
  • Fundus examination.
  • Otoscopy to assess ear canal patency.

Eligible participants will undergo additional measurements of central corneal thickness, corneal hysteresis, and optic nerve ultrasonography.

Intraocular pressure and DPOAE measurements will be assessed in different body positions, including sitting, supine, semi-reclined, and prone positions. The order of body positions will be randomly assigned using a computer-generated sequence.

Participants will maintain each assigned position for at least 30 minutes before the measurements.

DPOAEs will be recorded using a portable measurement system with a probe placed in the ear canal. Measurements will be performed over a frequency range of 500 to 4000 Hz.

In the sitting position, DPOAE measurements will be repeated after removing and reinserting the ear probe to evaluate test-retest repeatability.

**Outcome Assessment**

The primary endpoint is the repeatability of DPOAE phase measurements in glaucoma patients and healthy subjects.

Secondary assessments will investigate differences and correlations between DPOAE phase changes and intraocular pressure changes across different body positions, including their relationships with central corneal thickness and corneal hysteresis.

All study assessments will be completed during a single study visit consisting of screening and testing procedures. No additional study-specific follow-up visits are planned.

The findings may contribute to the development of noninvasive methods for investigating pressure-related mechanisms in glaucoma.

Opintotyyppi

Interventio

Ilmoittautuminen (Arvioitu)

112

Vaihe

  • Ei sovellettavissa

Yhteystiedot ja paikat

Tässä osiossa on tutkimuksen suorittajien yhteystiedot ja tiedot siitä, missä tämä tutkimus suoritetaan.

Opiskeluyhteys

Tutki yhteystietojen varmuuskopiointi

Opiskelupaikat

Osallistumiskriteerit

Tutkijat etsivät ihmisiä, jotka sopivat tiettyyn kuvaukseen, jota kutsutaan kelpoisuuskriteereiksi. Joitakin esimerkkejä näistä kriteereistä ovat henkilön yleinen terveydentila tai aiemmat hoidot.

Kelpoisuusvaatimukset

Opintokelpoiset iät

50 vuotta - 70 vuotta (Aikuinen, Vanhempi Aikuinen)

Hyväksyy terveitä vapaaehtoisia

Joo

Sukupuolet, jotka voivat opiskella

Kaikki

Kuvaus

**Inclusion Criteria:**

General inclusion criteria (all participants):

  • Age between 50 and 70 years.
  • Central corneal thickness between 500 and 600 µm.
  • Patent ear canal at otoscopy.
  • Written informed consent freely provided before the start of any study procedures.
  • Ability to understand and willingness to follow study instructions and likely to complete all required study visits and procedures.

Additional inclusion criteria for healthy subjects:

  • No eye disease.
  • No family history of glaucoma.

Additional inclusion criteria for glaucoma patients:

  • Clinical diagnosis of primary open-angle glaucoma, normal-tension glaucoma, pseudoexfoliative glaucoma, or pigmentary glaucoma.
  • Reproducible visual field defect on the Humphrey Field Analyzer (HFA) 24-2 test compatible with glaucoma, defined by the presence of a cluster of three or more non-continuous points in the pattern deviation plot with a probability of occurrence in the normal population of less than 5%, including at least one point with p < 1%, a pattern standard deviation with p < 5%, or a Glaucoma Hemifield Test result outside normal limits.
  • Optic nerve head (ONH) abnormalities compatible with glaucoma, including generalized or focal enlargement of the optic cup, thinning of the neuroretinal rim, cup-to-disc ratio asymmetry greater than 0.2 between eyes, or retinal nerve fiber layer loss.

**Exclusion Criteria:**

General exclusion criteria (all participants):

  • History of inner or middle ear disease.
  • History of cerebral diseases that may increase intracranial pressure (ICP), including neoplastic, ischemic, toxic, or infectious causes of cerebral edema, hydrocephalus, obstruction of major venous sinuses, vascular malformations, or idiopathic intracranial hypertension.
  • Systemic treatment with medications known to affect ICP, including corticosteroids, nitroprusside, nitroglycerin, hydralazine, nicardipine, topiramate, and loop diuretics (e.g., furosemide).
  • Non-recordable distortion product otoacoustic emissions (DPOAEs).
  • Uncontrolled blood pressure, with or without systemic treatment.
  • Retinal or optic nerve head diseases other than glaucoma, as assessed by optical coherence tomography (OCT) scans of the macula, optic nerve head, and retinal nerve fiber layer (RNFL).
  • Phacoemulsification or glaucoma filtering surgery within the previous 6 months.

Additional exclusion criterion for healthy subjects:

- Intraocular pressure (IOP) greater than 21 mmHg.

Additional exclusion criterion for glaucoma patients:

- Oral acetazolamide treatment as part of the therapeutic regimen, due to its potential effect on intracranial pressure.

Opintosuunnitelma

Tässä osiossa on tietoja tutkimussuunnitelmasta, mukaan lukien kuinka tutkimus on suunniteltu ja mitä tutkimuksella mitataan.

Miten tutkimus on suunniteltu?

Suunnittelun yksityiskohdat

  • Ensisijainen käyttötarkoitus: Diagnostiikka
  • Jako: Ei satunnaistettu
  • Inventiomalli: Rinnakkaistehtävä
  • Naamiointi: Ei mitään (avoin tarra)

Aseet ja interventiot

Osallistujaryhmä / Arm
Interventio / Hoito
Kokeellinen: Glaucoma Patients

Patients diagnosed with glaucoma who will undergo noninvasive distortion product otoacoustic emission (DPOAE) measurements and intraocular pressure assessments in different body positions. DPOAE phase measurements will be used to evaluate test-retest repeatability and investigate the relationship between otoacoustic emission changes and intraocular pressure variations.

Noninvasive measurement of distortion product otoacoustic emissions (DPOAEs) using the Titan System with IMP440 Impedance System version 3.7 (Interacoustics A/S, Denmark).

DPOAE phase measurements will be performed in different body positions (sitting at 90°, semi-reclined at 135°, supine at 180°, and prone at 0°), with the order randomly assigned using a computer-generated sequence.

Participants will maintain each position for at least 30 minutes before DPOAE and intraocular pressure measurements. DPOAEs will be recorded over a frequency range of 500 to 4000 Hz.

In the sitting position, DPOAE measurements will be repeated three times to assess test-retest repeatability.

Kokeellinen: Healthy Subjects

Healthy participants without glaucoma who will undergo the same noninvasive distortion product otoacoustic emission (DPOAE) measurements and intraocular pressure assessments in different body positions. Measurements will be used to evaluate test-retest repeatability and provide comparative data for the glaucoma group.

Noninvasive measurement of distortion product otoacoustic emissions (DPOAEs) using the Titan System with IMP440 Impedance System version 3.7 (Interacoustics A/S, Denmark).

DPOAE phase measurements will be performed in different body positions (sitting at 90°, semi-reclined at 135°, supine at 180°, and prone at 0°), with the order randomly assigned using a computer-generated sequence.

Participants will maintain each position for at least 30 minutes before DPOAE and intraocular pressure measurements. DPOAEs will be recorded over a frequency range of 500 to 4000 Hz.

In the sitting position, DPOAE measurements will be repeated three times to assess test-retest repeatability.

Mitä tutkimuksessa mitataan?

Ensisijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
Repeatability of Distortion Product Otoacoustic Emission (DPOAE) Phase Measurements
Aikaikkuna: During the single study visit (Day 1)

Assessment of the test-retest repeatability of distortion product otoacoustic emission (DPOAE) phase measurements in glaucoma patients and healthy subjects. DPOAE phase will be measured repeatedly in the sitting position (90°), with removal and reinsertion of the ear probe between measurements. Repeatability will be quantified as the standard deviation of differences between repeated measurements, expressed in degrees of phase.

During the single study visit (Day 1)

Toissijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
Differences in DPOAE Phase Changes and Intraocular Pressure Changes Between Study Groups
Aikaikkuna: During the single study visit (Day 1)

Comparison of distortion product otoacoustic emission (DPOAE) phase changes, expressed in degrees and averaged over three octave bands (0.5-1, 1-2, and 2-4 kHz), and mean changes in intraocular pressure (ΔIOP), expressed in mmHg, between glaucoma patients and healthy subjects across different body positions (90°, 135°, 180°, and 0°).

During the single study visit (Day 1)
Association Between DPOAE Phase Changes, Intraocular Pressure Changes, and Corneal Parameters
Aikaikkuna: During the single study visit (Day 1)

Assessment of the relationship between distortion product otoacoustic emission (DPOAE) phase changes (degrees) and intraocular pressure changes (ΔIOP, mmHg) across different body positions, considering central corneal thickness (µm) and corneal hysteresis (mmHg). Associations will be evaluated using Pearson or Spearman correlation coefficients and mixed-effects models.

During the single study visit (Day 1)

Yhteistyökumppanit ja tutkijat

Täältä löydät tähän tutkimukseen osallistuvat ihmiset ja organisaatiot.

Opintojen ennätyspäivät

Nämä päivämäärät seuraavat ClinicalTrials.gov-sivustolle lähetettyjen tutkimustietueiden ja yhteenvetojen edistymistä. National Library of Medicine (NLM) tarkistaa tutkimustiedot ja raportoidut tulokset varmistaakseen, että ne täyttävät tietyt laadunvalvontastandardit, ennen kuin ne julkaistaan ​​julkisella verkkosivustolla.

Opi tärkeimmät päivämäärät

Opiskelun aloitus (Todellinen)

Keskiviikko 11. marraskuuta 2026

Ensisijainen valmistuminen (Arvioitu)

Torstai 11. marraskuuta 2027

Opintojen valmistuminen (Arvioitu)

Torstai 11. marraskuuta 2027

Opintoihin ilmoittautumispäivät

Ensimmäinen lähetetty

Perjantai 20. marraskuuta 2026

Ensimmäinen toimitettu, joka täytti QC-kriteerit

Perjantai 20. marraskuuta 2026

Ensimmäinen Lähetetty (Todellinen)

Perjantai 27. marraskuuta 2026

Tutkimustietojen päivitykset

Viimeisin päivitys julkaistu (Todellinen)

Perjantai 27. marraskuuta 2026

Viimeisin lähetetty päivitys, joka täytti QC-kriteerit

Perjantai 20. marraskuuta 2026

Viimeksi vahvistettu

Sunnuntai 1. marraskuuta 2026

Lisää tietoa

Tähän tutkimukseen liittyvät termit

Yksittäisten osallistujien tietojen suunnitelma (IPD)

Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?

PÄÄTTÄMÄTÖN

Lääke- ja laitetiedot, tutkimusasiakirjat

Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta

Ei

Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta

Ei

Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .

Tilaa