Noninvasive Assessment of Intracranial Pressure Using Otoacoustic Emissions in Healthy Subjects and Glaucoma Patients (COSMO)
Noninvasive Intracranial Pressure Assessment Using Otoacoustic Emissions in Healthy Subjects and Glaucoma Patients
The COSMO study aims to investigate whether a noninvasive test based on otoacoustic emissions, which are sounds produced by the inner ear, can provide useful information about changes in intracranial pressure in people with glaucoma and healthy individuals.
Glaucoma is an eye disease that can damage the optic nerve and cause vision loss. Researchers believe that the relationship between pressure inside the eye and pressure inside the skull may play a role in glaucoma.
This study will compare measurements of distortion product otoacoustic emissions (DPOAEs) between patients with glaucoma and healthy participants. Researchers will assess how reproducible these measurements are and how they change with different body positions and changes in intraocular pressure.
Participants will undergo eye examinations and noninvasive ear measurements while assuming different body positions.
The results may help researchers better understand the relationship between intracranial pressure, intraocular pressure, and glaucoma, and evaluate the potential usefulness of otoacoustic emissions as a noninvasive assessment method.
研究概览
详细说明
COSMO is a single-center, prospective, interventional clinical study with a medical device designed to investigate the reproducibility of distortion product otoacoustic emission (DPOAE) phase measurements in patients with glaucoma and healthy subjects.
The study is based on the hypothesis that changes in intracranial pressure may influence otoacoustic emissions and that the relationship between intracranial pressure and intraocular pressure (IOP) may be relevant to glaucoma.
**Primary Objective**
To assess the reproducibility of DPOAE phase measurements and compare their repeatability between patients with glaucoma and healthy subjects.
**Secondary Objectives**
- To compare changes in DPOAE phase and intraocular pressure (ΔIOP) between glaucoma patients and healthy subjects.
- To investigate the relationship between DPOAE phase changes and intraocular pressure changes across different body positions.
- To explore the influence of central corneal thickness and corneal hysteresis on these relationships.
**Study Procedures**
Following written informed consent, participants will undergo a screening assessment to confirm eligibility.
Screening examinations will include:
- Best-corrected visual acuity assessment.
- Anterior segment biomicroscopy.
- Visual field testing in glaucoma patients.
- Optical coherence tomography (OCT) of the optic nerve head and macula.
- Intraocular pressure measurement.
- Fundus examination.
- Otoscopy to assess ear canal patency.
Eligible participants will undergo additional measurements of central corneal thickness, corneal hysteresis, and optic nerve ultrasonography.
Intraocular pressure and DPOAE measurements will be assessed in different body positions, including sitting, supine, semi-reclined, and prone positions. The order of body positions will be randomly assigned using a computer-generated sequence.
Participants will maintain each assigned position for at least 30 minutes before the measurements.
DPOAEs will be recorded using a portable measurement system with a probe placed in the ear canal. Measurements will be performed over a frequency range of 500 to 4000 Hz.
In the sitting position, DPOAE measurements will be repeated after removing and reinserting the ear probe to evaluate test-retest repeatability.
**Outcome Assessment**
The primary endpoint is the repeatability of DPOAE phase measurements in glaucoma patients and healthy subjects.
Secondary assessments will investigate differences and correlations between DPOAE phase changes and intraocular pressure changes across different body positions, including their relationships with central corneal thickness and corneal hysteresis.
All study assessments will be completed during a single study visit consisting of screening and testing procedures. No additional study-specific follow-up visits are planned.
The findings may contribute to the development of noninvasive methods for investigating pressure-related mechanisms in glaucoma.
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习联系方式
- 姓名:Francesco Oddone, MD
- 电话号码:+390684009442
- 邮箱:francesco.oddone@fondazionebietti.it
研究联系人备份
- 姓名:Sara Giammaria, MD
- 邮箱:sara.giammaria@fondazionebietti.it
学习地点
-
-
-
Roma、意大利、00184
- 招聘中
- IRCCS Fondazione G.B.Bietti
-
接触:
- Sara Giammaria
- 电话号码:+390684009442
- 邮箱:sara.giammaria@fondazionebietti.it
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
**Inclusion Criteria:**
General inclusion criteria (all participants):
- Age between 50 and 70 years.
- Central corneal thickness between 500 and 600 µm.
- Patent ear canal at otoscopy.
- Written informed consent freely provided before the start of any study procedures.
- Ability to understand and willingness to follow study instructions and likely to complete all required study visits and procedures.
Additional inclusion criteria for healthy subjects:
- No eye disease.
- No family history of glaucoma.
Additional inclusion criteria for glaucoma patients:
- Clinical diagnosis of primary open-angle glaucoma, normal-tension glaucoma, pseudoexfoliative glaucoma, or pigmentary glaucoma.
- Reproducible visual field defect on the Humphrey Field Analyzer (HFA) 24-2 test compatible with glaucoma, defined by the presence of a cluster of three or more non-continuous points in the pattern deviation plot with a probability of occurrence in the normal population of less than 5%, including at least one point with p < 1%, a pattern standard deviation with p < 5%, or a Glaucoma Hemifield Test result outside normal limits.
- Optic nerve head (ONH) abnormalities compatible with glaucoma, including generalized or focal enlargement of the optic cup, thinning of the neuroretinal rim, cup-to-disc ratio asymmetry greater than 0.2 between eyes, or retinal nerve fiber layer loss.
**Exclusion Criteria:**
General exclusion criteria (all participants):
- History of inner or middle ear disease.
- History of cerebral diseases that may increase intracranial pressure (ICP), including neoplastic, ischemic, toxic, or infectious causes of cerebral edema, hydrocephalus, obstruction of major venous sinuses, vascular malformations, or idiopathic intracranial hypertension.
- Systemic treatment with medications known to affect ICP, including corticosteroids, nitroprusside, nitroglycerin, hydralazine, nicardipine, topiramate, and loop diuretics (e.g., furosemide).
- Non-recordable distortion product otoacoustic emissions (DPOAEs).
- Uncontrolled blood pressure, with or without systemic treatment.
- Retinal or optic nerve head diseases other than glaucoma, as assessed by optical coherence tomography (OCT) scans of the macula, optic nerve head, and retinal nerve fiber layer (RNFL).
- Phacoemulsification or glaucoma filtering surgery within the previous 6 months.
Additional exclusion criterion for healthy subjects:
- Intraocular pressure (IOP) greater than 21 mmHg.
Additional exclusion criterion for glaucoma patients:
- Oral acetazolamide treatment as part of the therapeutic regimen, due to its potential effect on intracranial pressure.
学习计划
研究是如何设计的?
设计细节
- 主要用途:诊断
- 分配:非随机化
- 介入模型:并行分配
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:Glaucoma Patients
Patients diagnosed with glaucoma who will undergo noninvasive distortion product otoacoustic emission (DPOAE) measurements and intraocular pressure assessments in different body positions. DPOAE phase measurements will be used to evaluate test-retest repeatability and investigate the relationship between otoacoustic emission changes and intraocular pressure variations. |
Noninvasive measurement of distortion product otoacoustic emissions (DPOAEs) using the Titan System with IMP440 Impedance System version 3.7 (Interacoustics A/S, Denmark). DPOAE phase measurements will be performed in different body positions (sitting at 90°, semi-reclined at 135°, supine at 180°, and prone at 0°), with the order randomly assigned using a computer-generated sequence. Participants will maintain each position for at least 30 minutes before DPOAE and intraocular pressure measurements. DPOAEs will be recorded over a frequency range of 500 to 4000 Hz. In the sitting position, DPOAE measurements will be repeated three times to assess test-retest repeatability. |
|
实验性的:Healthy Subjects
Healthy participants without glaucoma who will undergo the same noninvasive distortion product otoacoustic emission (DPOAE) measurements and intraocular pressure assessments in different body positions. Measurements will be used to evaluate test-retest repeatability and provide comparative data for the glaucoma group. |
Noninvasive measurement of distortion product otoacoustic emissions (DPOAEs) using the Titan System with IMP440 Impedance System version 3.7 (Interacoustics A/S, Denmark). DPOAE phase measurements will be performed in different body positions (sitting at 90°, semi-reclined at 135°, supine at 180°, and prone at 0°), with the order randomly assigned using a computer-generated sequence. Participants will maintain each position for at least 30 minutes before DPOAE and intraocular pressure measurements. DPOAEs will be recorded over a frequency range of 500 to 4000 Hz. In the sitting position, DPOAE measurements will be repeated three times to assess test-retest repeatability. |
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Repeatability of Distortion Product Otoacoustic Emission (DPOAE) Phase Measurements
大体时间:During the single study visit (Day 1)
|
Assessment of the test-retest repeatability of distortion product otoacoustic emission (DPOAE) phase measurements in glaucoma patients and healthy subjects. DPOAE phase will be measured repeatedly in the sitting position (90°), with removal and reinsertion of the ear probe between measurements. Repeatability will be quantified as the standard deviation of differences between repeated measurements, expressed in degrees of phase. |
During the single study visit (Day 1)
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Differences in DPOAE Phase Changes and Intraocular Pressure Changes Between Study Groups
大体时间:During the single study visit (Day 1)
|
Comparison of distortion product otoacoustic emission (DPOAE) phase changes, expressed in degrees and averaged over three octave bands (0.5-1, 1-2, and 2-4 kHz), and mean changes in intraocular pressure (ΔIOP), expressed in mmHg, between glaucoma patients and healthy subjects across different body positions (90°, 135°, 180°, and 0°). |
During the single study visit (Day 1)
|
|
Association Between DPOAE Phase Changes, Intraocular Pressure Changes, and Corneal Parameters
大体时间:During the single study visit (Day 1)
|
Assessment of the relationship between distortion product otoacoustic emission (DPOAE) phase changes (degrees) and intraocular pressure changes (ΔIOP, mmHg) across different body positions, considering central corneal thickness (µm) and corneal hysteresis (mmHg). Associations will be evaluated using Pearson or Spearman correlation coefficients and mixed-effects models. |
During the single study visit (Day 1)
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
关键字
其他研究编号
- GLC 04-23
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.