- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT01038791
Patients-ventilator Interaction During Sleep: Effect of Humidification System
Patients-ventilator Interaction During Sleep: the Role of Humidification. A Pilot Short Term Study
At present, little data is available in the medical literature regarding the affects of humidification on NIMV efficacy, sleep quality and upper airway symptoms in patients undergoing nocturnal NIMV.
The aim of the present pilot study is to assess the impact of two humidification systems on sleep quality, NIMV efficacy, patient-ventilator interaction, prevalence of NIMV side effects, compliance to treatment, in a group of stable patients already enrolled in a long-term nocturnal mechanical ventilation program for chronic hypercapnic respiratory failure or sleep hypoventilation.
연구 개요
상태
정황
상세 설명
BACKGROUND Non-invasive mechanical ventilation (NIMV), usually delivered during night time, is widely used at home in chronic hypercapnic respiratory, both in patients with COPD and restrictive thoracic diseases (RTD). The aim of chronic NIMV is to improve daytime arterial blood gases, sleep quality decreasing symptoms of hypoventilation (mainly during sleep), quality of life and mood.
Scarce data is available about the NIMV compliance at home; poor compliance may reduce the positive effects of mechanical ventilation. Previous data shows that patients enrolled to long-term home ventilation program may drop out early, mainly because of skin irritation, upper airway problems, and air leaks.
Studies performed on patients with sleep apnea, receiving CPAP therapy at home, showed that the occurrence of leaks during ventilation can cause the development of mucosal inflammation, nasal congestion and increased nasal airways resistance. On the other hand, the presence or the development of nasal obstruction makes the arise or the worsening of air leaks (the vicious cycle) more reliable.
A lack of humidification may increase nasal resistance and nasal symptoms and, therefore, contribute to reduction in compliance. Furthermore, leaks may have significant consequences on inspiratory and expiratory trigger functions, inducing poor patient-ventilator interactions. Indeed, the presence of ineffective efforts, the most common phenomenon of bad patient-ventilation interactions, is very common in patients receiving long term home ventilation and usually associated with poorer gas exchange during sleep.
At present, little data is available in the medical literature regarding the affects of humidification on NIMV efficacy, sleep quality and upper airway symptoms in patients undergoing nocturnal NIMV.
The aim of the present pilot study is to assess the impact of two humidification systems on sleep quality, NIMV efficacy, patient-ventilator interaction, prevalence of NIMV side effects, compliance to treatment, in a group of stable patients already enrolled in a long-term nocturnal mechanical ventilation program for chronic hypercapnic respiratory failure or sleep hypoventilation.
PATIENTS We plan to enrol 20 patients with chronic respiratory failure or sleep hypoventilation already included in a long-term home non-invasive ventilation program (at least 3 months).
Inclusion criteria Patients in stable conditions (no acute exacerbations in the 4 weeks before enrolment), well adapted to ventilation and without problems with the ventilation mask.
Exclusions criteria Patients with acute respiratory failure, recent exacerbations, severe co-morbidities (i.e. hearth failure, recent stroke etc.) Recent upper airways surgery. Allergic rhinitis, severe nasal stenosis.
STUDY DESIGN
Patients will undergo three consecutive nocturnal polysomnographs. Patients will have a baseline therapy of NIMV without humidification for 1 week. They will then undergo a nocturnal polysomnograph on the last evening of the baseline therapy. Patients will then be randomly assigned to use HH or HME for 1 week and undergo a nocturnal polysomnography on the last evening . The patients will then be assigned to the second method of humidification for 1 week and undergo a third nocturnal polysomnograph on the last evening. The whole evaluation will be performed with the same ventilator (ideally the patient's device) using the patient's mask and with the usual ventilator setting.
Measures
At enrolment:
Lung function test Standard questionnaire about the use and tolerability of NIMV at home Measure of NIMV compliance at home Blood gas analysis during wakefulness (during spontaneous breathing - SB - and during NIMV) The breathing pattern during wakefulness (during SB and NIMV)
Polysomnographic evaluation
Full standard assisted polysomnography with simultaneous recordings of Tidal Volume, Leaks, pressure in mask, respiratory rate, instantaneous minute ventilation.
Analysis of sleep data will be performed according to standard criteria (AASM 2007).
Analysis of breathing pattern and patients-ventilator interaction will be made according to previous published methods (Fanfulla, Tuggey, Techsler etc..).
At the end of the each PSG recording, patients will be asked about their humidification and NIMV tolerance as well as the presence of upper airway symptoms (Nava et al).
연구 유형
등록 (실제)
단계
- 4단계
연락처 및 위치
연구 장소
-
-
-
Pavia, 이탈리아, 27100
- Fondazione S.Maugeri
-
-
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
설명
Inclusion Criteria:
- Patients in stable conditions (no acute exacerbations in the 4 weeks before enrolment), well adapted to ventilation and without problems with the ventilation mask.
Exclusion Criteria:
- Patients with acute respiratory failure, recent exacerbations, severe co-morbidities (i.e. hearth failure, recent stroke etc.)
- Recent upper airways surgery.
- Allergic rhinitis, severe nasal stenosis.
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 지지 요법
- 할당: 무작위
- 중재 모델: 크로스오버 할당
- 마스킹: 하나의
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
활성 비교기: usual ventilation
application of usual mechanical ventilation without humidification system
|
mechanical ventilation with usual parameters
다른 이름들:
|
|
실험적: heated humidifier
mechanical ventilation with heated humidifier
|
temperature 35°
다른 이름들:
|
|
실험적: heat and moisture exchanger
mechanical ventilation with heat and moisture exchanger
|
single patient device
다른 이름들:
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
기간 |
|---|---|
|
sleep quality and asynchrony index
기간: 8 hrs
|
8 hrs
|
2차 결과 측정
결과 측정 |
기간 |
|---|---|
|
tolerance assessed using an ad-hoc designed scale (1 t0 5 scale), and the effective hours of sleep
기간: 8 hrs
|
8 hrs
|
공동 작업자 및 조사자
수사관
- 수석 연구원: Francesco Fanfulla, MD, Fondazione S.Maugeri
간행물 및 유용한 링크
연구 기록 날짜
연구 주요 날짜
연구 시작
기본 완료 (실제)
연구 완료 (실제)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (추정)
연구 기록 업데이트
마지막 업데이트 게시됨 (추정)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
키워드
추가 관련 MeSH 약관
기타 연구 ID 번호
- 593
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
미국에서 제조되어 미국에서 수출되는 제품
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .