此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Patients-ventilator Interaction During Sleep: Effect of Humidification System

2014年10月8日 更新者:dr. Stefano Nava、IRCCS Azienda Ospedaliero-Universitaria di Bologna

Patients-ventilator Interaction During Sleep: the Role of Humidification. A Pilot Short Term Study

At present, little data is available in the medical literature regarding the affects of humidification on NIMV efficacy, sleep quality and upper airway symptoms in patients undergoing nocturnal NIMV.

The aim of the present pilot study is to assess the impact of two humidification systems on sleep quality, NIMV efficacy, patient-ventilator interaction, prevalence of NIMV side effects, compliance to treatment, in a group of stable patients already enrolled in a long-term nocturnal mechanical ventilation program for chronic hypercapnic respiratory failure or sleep hypoventilation.

研究概览

详细说明

BACKGROUND Non-invasive mechanical ventilation (NIMV), usually delivered during night time, is widely used at home in chronic hypercapnic respiratory, both in patients with COPD and restrictive thoracic diseases (RTD). The aim of chronic NIMV is to improve daytime arterial blood gases, sleep quality decreasing symptoms of hypoventilation (mainly during sleep), quality of life and mood.

Scarce data is available about the NIMV compliance at home; poor compliance may reduce the positive effects of mechanical ventilation. Previous data shows that patients enrolled to long-term home ventilation program may drop out early, mainly because of skin irritation, upper airway problems, and air leaks.

Studies performed on patients with sleep apnea, receiving CPAP therapy at home, showed that the occurrence of leaks during ventilation can cause the development of mucosal inflammation, nasal congestion and increased nasal airways resistance. On the other hand, the presence or the development of nasal obstruction makes the arise or the worsening of air leaks (the vicious cycle) more reliable.

A lack of humidification may increase nasal resistance and nasal symptoms and, therefore, contribute to reduction in compliance. Furthermore, leaks may have significant consequences on inspiratory and expiratory trigger functions, inducing poor patient-ventilator interactions. Indeed, the presence of ineffective efforts, the most common phenomenon of bad patient-ventilation interactions, is very common in patients receiving long term home ventilation and usually associated with poorer gas exchange during sleep.

At present, little data is available in the medical literature regarding the affects of humidification on NIMV efficacy, sleep quality and upper airway symptoms in patients undergoing nocturnal NIMV.

The aim of the present pilot study is to assess the impact of two humidification systems on sleep quality, NIMV efficacy, patient-ventilator interaction, prevalence of NIMV side effects, compliance to treatment, in a group of stable patients already enrolled in a long-term nocturnal mechanical ventilation program for chronic hypercapnic respiratory failure or sleep hypoventilation.

PATIENTS We plan to enrol 20 patients with chronic respiratory failure or sleep hypoventilation already included in a long-term home non-invasive ventilation program (at least 3 months).

Inclusion criteria Patients in stable conditions (no acute exacerbations in the 4 weeks before enrolment), well adapted to ventilation and without problems with the ventilation mask.

Exclusions criteria Patients with acute respiratory failure, recent exacerbations, severe co-morbidities (i.e. hearth failure, recent stroke etc.) Recent upper airways surgery. Allergic rhinitis, severe nasal stenosis.

STUDY DESIGN

Patients will undergo three consecutive nocturnal polysomnographs. Patients will have a baseline therapy of NIMV without humidification for 1 week. They will then undergo a nocturnal polysomnograph on the last evening of the baseline therapy. Patients will then be randomly assigned to use HH or HME for 1 week and undergo a nocturnal polysomnography on the last evening . The patients will then be assigned to the second method of humidification for 1 week and undergo a third nocturnal polysomnograph on the last evening. The whole evaluation will be performed with the same ventilator (ideally the patient's device) using the patient's mask and with the usual ventilator setting.

Measures

At enrolment:

Lung function test Standard questionnaire about the use and tolerability of NIMV at home Measure of NIMV compliance at home Blood gas analysis during wakefulness (during spontaneous breathing - SB - and during NIMV) The breathing pattern during wakefulness (during SB and NIMV)

Polysomnographic evaluation

Full standard assisted polysomnography with simultaneous recordings of Tidal Volume, Leaks, pressure in mask, respiratory rate, instantaneous minute ventilation.

Analysis of sleep data will be performed according to standard criteria (AASM 2007).

Analysis of breathing pattern and patients-ventilator interaction will be made according to previous published methods (Fanfulla, Tuggey, Techsler etc..).

At the end of the each PSG recording, patients will be asked about their humidification and NIMV tolerance as well as the presence of upper airway symptoms (Nava et al).

研究类型

介入性

注册 (实际的)

15

阶段

  • 第四阶段

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

      • Pavia、意大利、27100
        • Fondazione S.Maugeri

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 至 90年 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

描述

Inclusion Criteria:

  • Patients in stable conditions (no acute exacerbations in the 4 weeks before enrolment), well adapted to ventilation and without problems with the ventilation mask.

Exclusion Criteria:

  • Patients with acute respiratory failure, recent exacerbations, severe co-morbidities (i.e. hearth failure, recent stroke etc.)
  • Recent upper airways surgery.
  • Allergic rhinitis, severe nasal stenosis.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:支持治疗
  • 分配:随机化
  • 介入模型:交叉作业
  • 屏蔽:单身的

武器和干预

参与者组/臂
干预/治疗
有源比较器:usual ventilation
application of usual mechanical ventilation without humidification system
mechanical ventilation with usual parameters
其他名称:
  • 控制
实验性的:heated humidifier
mechanical ventilation with heated humidifier
temperature 35°
其他名称:
  • 赫赫
实验性的:heat and moisture exchanger
mechanical ventilation with heat and moisture exchanger
single patient device
其他名称:
  • HME

研究衡量的是什么?

主要结果指标

结果测量
大体时间
sleep quality and asynchrony index
大体时间:8 hrs
8 hrs

次要结果测量

结果测量
大体时间
tolerance assessed using an ad-hoc designed scale (1 t0 5 scale), and the effective hours of sleep
大体时间:8 hrs
8 hrs

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Francesco Fanfulla, MD、Fondazione S.Maugeri

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始

2009年12月1日

初级完成 (实际的)

2014年6月1日

研究完成 (实际的)

2014年6月1日

研究注册日期

首次提交

2009年12月16日

首先提交符合 QC 标准的

2009年12月23日

首次发布 (估计)

2009年12月24日

研究记录更新

最后更新发布 (估计)

2014年10月9日

上次提交的符合 QC 标准的更新

2014年10月8日

最后验证

2013年1月1日

更多信息

与本研究相关的术语

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

在美国制造并从美国出口的产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅