Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Patients-ventilator Interaction During Sleep: Effect of Humidification System

8. oktober 2014 opdateret af: dr. Stefano Nava, IRCCS Azienda Ospedaliero-Universitaria di Bologna

Patients-ventilator Interaction During Sleep: the Role of Humidification. A Pilot Short Term Study

At present, little data is available in the medical literature regarding the affects of humidification on NIMV efficacy, sleep quality and upper airway symptoms in patients undergoing nocturnal NIMV.

The aim of the present pilot study is to assess the impact of two humidification systems on sleep quality, NIMV efficacy, patient-ventilator interaction, prevalence of NIMV side effects, compliance to treatment, in a group of stable patients already enrolled in a long-term nocturnal mechanical ventilation program for chronic hypercapnic respiratory failure or sleep hypoventilation.

Studieoversigt

Detaljeret beskrivelse

BACKGROUND Non-invasive mechanical ventilation (NIMV), usually delivered during night time, is widely used at home in chronic hypercapnic respiratory, both in patients with COPD and restrictive thoracic diseases (RTD). The aim of chronic NIMV is to improve daytime arterial blood gases, sleep quality decreasing symptoms of hypoventilation (mainly during sleep), quality of life and mood.

Scarce data is available about the NIMV compliance at home; poor compliance may reduce the positive effects of mechanical ventilation. Previous data shows that patients enrolled to long-term home ventilation program may drop out early, mainly because of skin irritation, upper airway problems, and air leaks.

Studies performed on patients with sleep apnea, receiving CPAP therapy at home, showed that the occurrence of leaks during ventilation can cause the development of mucosal inflammation, nasal congestion and increased nasal airways resistance. On the other hand, the presence or the development of nasal obstruction makes the arise or the worsening of air leaks (the vicious cycle) more reliable.

A lack of humidification may increase nasal resistance and nasal symptoms and, therefore, contribute to reduction in compliance. Furthermore, leaks may have significant consequences on inspiratory and expiratory trigger functions, inducing poor patient-ventilator interactions. Indeed, the presence of ineffective efforts, the most common phenomenon of bad patient-ventilation interactions, is very common in patients receiving long term home ventilation and usually associated with poorer gas exchange during sleep.

At present, little data is available in the medical literature regarding the affects of humidification on NIMV efficacy, sleep quality and upper airway symptoms in patients undergoing nocturnal NIMV.

The aim of the present pilot study is to assess the impact of two humidification systems on sleep quality, NIMV efficacy, patient-ventilator interaction, prevalence of NIMV side effects, compliance to treatment, in a group of stable patients already enrolled in a long-term nocturnal mechanical ventilation program for chronic hypercapnic respiratory failure or sleep hypoventilation.

PATIENTS We plan to enrol 20 patients with chronic respiratory failure or sleep hypoventilation already included in a long-term home non-invasive ventilation program (at least 3 months).

Inclusion criteria Patients in stable conditions (no acute exacerbations in the 4 weeks before enrolment), well adapted to ventilation and without problems with the ventilation mask.

Exclusions criteria Patients with acute respiratory failure, recent exacerbations, severe co-morbidities (i.e. hearth failure, recent stroke etc.) Recent upper airways surgery. Allergic rhinitis, severe nasal stenosis.

STUDY DESIGN

Patients will undergo three consecutive nocturnal polysomnographs. Patients will have a baseline therapy of NIMV without humidification for 1 week. They will then undergo a nocturnal polysomnograph on the last evening of the baseline therapy. Patients will then be randomly assigned to use HH or HME for 1 week and undergo a nocturnal polysomnography on the last evening . The patients will then be assigned to the second method of humidification for 1 week and undergo a third nocturnal polysomnograph on the last evening. The whole evaluation will be performed with the same ventilator (ideally the patient's device) using the patient's mask and with the usual ventilator setting.

Measures

At enrolment:

Lung function test Standard questionnaire about the use and tolerability of NIMV at home Measure of NIMV compliance at home Blood gas analysis during wakefulness (during spontaneous breathing - SB - and during NIMV) The breathing pattern during wakefulness (during SB and NIMV)

Polysomnographic evaluation

Full standard assisted polysomnography with simultaneous recordings of Tidal Volume, Leaks, pressure in mask, respiratory rate, instantaneous minute ventilation.

Analysis of sleep data will be performed according to standard criteria (AASM 2007).

Analysis of breathing pattern and patients-ventilator interaction will be made according to previous published methods (Fanfulla, Tuggey, Techsler etc..).

At the end of the each PSG recording, patients will be asked about their humidification and NIMV tolerance as well as the presence of upper airway symptoms (Nava et al).

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

15

Fase

  • Fase 4

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

      • Pavia, Italien, 27100
        • Fondazione S.Maugeri

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år til 90 år (Voksen, Ældre voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

  • Patients in stable conditions (no acute exacerbations in the 4 weeks before enrolment), well adapted to ventilation and without problems with the ventilation mask.

Exclusion Criteria:

  • Patients with acute respiratory failure, recent exacerbations, severe co-morbidities (i.e. hearth failure, recent stroke etc.)
  • Recent upper airways surgery.
  • Allergic rhinitis, severe nasal stenosis.

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Støttende pleje
  • Tildeling: Randomiseret
  • Interventionel model: Crossover opgave
  • Maskning: Enkelt

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Aktiv komparator: usual ventilation
application of usual mechanical ventilation without humidification system
mechanical ventilation with usual parameters
Andre navne:
  • styring
Eksperimentel: heated humidifier
mechanical ventilation with heated humidifier
temperature 35°
Andre navne:
  • HH
Eksperimentel: heat and moisture exchanger
mechanical ventilation with heat and moisture exchanger
single patient device
Andre navne:
  • HME

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Tidsramme
sleep quality and asynchrony index
Tidsramme: 8 hrs
8 hrs

Sekundære resultatmål

Resultatmål
Tidsramme
tolerance assessed using an ad-hoc designed scale (1 t0 5 scale), and the effective hours of sleep
Tidsramme: 8 hrs
8 hrs

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Efterforskere

  • Ledende efterforsker: Francesco Fanfulla, MD, Fondazione S.Maugeri

Publikationer og nyttige links

Den person, der er ansvarlig for at indtaste oplysninger om undersøgelsen, leverer frivilligt disse publikationer. Disse kan handle om alt relateret til undersøgelsen.

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart

1. december 2009

Primær færdiggørelse (Faktiske)

1. juni 2014

Studieafslutning (Faktiske)

1. juni 2014

Datoer for studieregistrering

Først indsendt

16. december 2009

Først indsendt, der opfyldte QC-kriterier

23. december 2009

Først opslået (Skøn)

24. december 2009

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Skøn)

9. oktober 2014

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

8. oktober 2014

Sidst verificeret

1. januar 2013

Mere information

Begreber relateret til denne undersøgelse

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ingen

produkt fremstillet i og eksporteret fra U.S.A.

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Kliniske forsøg med usual mechanical ventilation without humidification

Abonner