- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT02988492
Acute Stroke Thrombectomy: Does CT Perfusion Accurately Predict Infarct on MRI After Recanalization
The newest generation of stent---retrievers results in higher recanalization rates and faster recanalization time compared to older generation endovascular therapies for acute stroke. Advanced neuroimaging can potentially improve the assessment of infarct core and inform decision---making in patients being considered for endovascular therapy. Evaluation of infarct core may be performed with NECT, CTASI or CT perfusion. In the past, evaluation of CTP in predicting core infarct in acute stroke has been limited because recanalization status was lacking. In addition, final infarct size may be underestimated on NECT compared with MRI. These two limitations can now be addressed: the new generation of stent---retrievers allows accurate determination recanalization time; evaluating the test characteristics of CTP using 24 hour DWI---MRI as the reference standard can be readily performed.
We aim to prospectively investigate the sensitivity and specificity of whole---brain CTP in predicting 24 hour DWI---MRI infarct in patients with acute proximal anterior circulation occlusions successfully recanalized with endovascular treatment.
연구 개요
연구 유형
등록 (실제)
단계
- 해당 없음
연락처 및 위치
연구 장소
-
-
Ontario
-
Ottawa, Ontario, 캐나다, K1Y 4E9
- The Ottawa Hospital
-
-
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
설명
Inclusion Criteria:
- Admission NECT, CTA neck and COW or multi-phase CTA or CTP. Follow---up 24 hr DWI---MRI performed
- Endovascular therapy performed for acute anterior circulation stroke as per clinical practice.
- Patient with an angiographically documented ICA, M1 or M2 occlusion
Exclusion Criteria:
None
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 특수 증상
- 할당: 해당 없음
- 중재 모델: 단일 그룹 할당
- 마스킹: 없음(오픈 라벨)
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
다른: MRI perfusion imaging
MRI screening will be performed as per standard-of-care by the MRI technologist staff.
Imaging will be performed with 1.5 T or 3 T systems (Magnetom Vision; Siemens, Erlangen, Germany) using a multisection, single shot, spin echo, echo planer imaging sequence.
Diffusion gradients will be applied in each of the x, y and z directions with three b values (0, 500 and 1000 s/mm2).
Imaging parameters include a TE of 94 ms, field of view of 23 cm, matrix of 128 and section thickness of 5.5 mm for the 1.5 T system and a TE of 83 ms, field of view of 23 cm, matrix of 128 and section thickness of 3 mm for the 3 T system.
Conventional spin echo imaging also will be performed at each examination under T1 and T2 weighted conditions, with a fluid attenuated inversion recovery sequence and Time-of-flight MRA of the Circle-of-Willis.
|
Evaluate the sensitivity and specificity of whole---brain CTP in predicting 24 hour DWI---MRI infarct in patients with acute proximal anterior circulation occlusions successfully recanalized with endovascular treatment.
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Evaluate the sensitivity and specificity of CTP
기간: Up to 24 months
|
The primary outcome of our study is to evaluate the sensitivity and specificity of CTP in predicting infarct on 24 hour DWI---MRI.
|
Up to 24 months
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Correlate advanced imaging to clinical outcome
기간: Up to 24 months
|
The secondary outcome of our study is to correlate advanced imaging to clinical outcome at 30 days.
|
Up to 24 months
|
공동 작업자 및 조사자
수사관
- 수석 연구원: Daniela Iancu, MD, The Ottawa Hospital
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
기본 완료 (실제)
연구 완료 (실제)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (추정)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .