- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT04077593
On the PhonE Respiratory rAte Study (OPERA) (OPERA)
Evaluation de la précision d'Une Mesure téléphonique de la fréquence Respiratoire à l'Aide d'Une Application Mobile - The OPERA Study (On the PhonE Respiratory rAte)
Introduction. The increasing use of telephone medical advice requires the development of telemedicine tools to assess the patient's severity. Respiratory rate (RR) is a simple vital parameter and is often associated with morbidity and mortality of patients. There is no standardized measure of RR by telephone.
Objective: The investigators wanted to evaluate the RR measurement by phone using a smartphone application called RRate.
Methods. Adults who have been admitted for less than 6 hours to the emergency department after calling Center 15 and whose main reason for consultation is dyspnea will be included. Patients with non-invasive or tracheotomized ventilation will be excluded. The main objective will be to compare by Bland-Altman method the accuracy of the RRate measurement by phone to a one-minute RR measurement at patient's bedside. Secondary endpoints will evaluate the length of RR measurement according to the different methods used; measurement failure criteria; the accuracy of different measurement techniques (RRate at patient's bedside, impedancemetry, traditional measurement during 15s or 30s).
Expected Results. The accuracy of the RR measurement by RRate over the telephone should be within the limits of agreement. The measurement time should be shorter with the RRate application than with traditional methods. However, the measurement by telephone should not always be feasible in patients with mild dyspnea or with poorly audible breathing.
연구 개요
연구 유형
등록 (실제)
연락처 및 위치
연구 장소
-
-
Isere
-
La Tronche, Isere, 프랑스, 38700
- Grenoble University Hospital
-
-
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
샘플링 방법
연구 인구
설명
Inclusion Criteria:
- Age >18yo
- Dyspnea as main reason for consultation
- Regulated by "Centre 15"
- Admitted for less than 6hours at emergency department
Exclusion Criteria:
- Non invasive or tracheotomized ventilation
- Cognitive impairment
- Pregnancy
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 관찰 모델: 다른
- 시간 관점: 유망한
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
RRate app on the phone precision
기간: 1 minute
|
To compare withBland-Altman analysis the accuracy of the RRate measurement by phone to a one-minute respiratory rate measurement at patient's bedside
|
1 minute
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Efficiency
기간: 1 minute
|
length of RR measurement according to the different methods used
|
1 minute
|
|
Measurement failure criteria by different Rrate methods (by phone, next to the patient and the reference method)
기간: 1 minute
|
Wether coughing, talking during measurement, phone hold by another person, has an impact on measurement possibility.
The gap between the measurement by different RRate methods (by phone, next to the patient and the reference method)
|
1 minute
|
|
Accuracy
기간: 1 minute
|
Bland Altman analysis : between one minute measurement at patient's bedside and other measurements : RRate app at patient's bedside, impedancemetry, traditional measurement during 15 seconds or 30 seconds
|
1 minute
|
|
Clinical impact
기간: 1 minute
|
qSOFA (sequential Organ Failure Assesment score) obtained with different measurement of the RRate at 60 second
|
1 minute
|
|
Reproducibility
기간: 1 minute
|
Coefficient of variation and Intra-class correlation, of respiratory rate measured twice with : RRate app on the phone, RRate app at patient's bedside, 15 seconds measurement.
|
1 minute
|
공동 작업자 및 조사자
수사관
- 수석 연구원: Maxime MD Maignan, PhD, University Hospital, Grenoble
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
기본 완료 (실제)
연구 완료 (실제)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .