- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT07621913
Comparison of Lower Extremity Parameters in Monofin and Bi-fin Swimmers.
Comparison of Lower Extremity Muscle Biomechanical Properties, Joint Range of Motion, and Performance Parameters in Monofin and Bi-fin Swimmers
The purpose of this study is to compare the leg muscle features and joint movements of swimmers who use a single large fin (monofin) versus those who use two fins (bi-fins). Different types of fins change how legs move in the water. This may affect the muscle structure and swimming performance. The researchers want to find out the differences between these two groups of swimmers.
During the study, the researchers will do the following:
Record the age, height, and weight of healthy swimmers who train regularly. Measure the stiffness and flexibility of the leg muscles using MyotonPro device.
Check how well the hips, knees, and ankles can move using digital goniometer.
The findings from this study will help create safer training programs for swimmers. Coaches will use the results to improve swimming performance and lower the risk of leg injuries.
연구 개요
상태
연구 유형
등록 (추정된)
연락처 및 위치
연구 장소
-
-
Avcılar
-
Istanbul, Avcılar, 터키 (Türkiye), 34310
- Istanbul Gelisim University
-
-
참여기준
자격 기준
공부할 수 있는 나이
- 어린이
- 성인
건강한 자원 봉사자를 받아들입니다
샘플링 방법
연구 인구
설명
Inclusion Criteria:
- Inclusion Criteria:
- Being between 12-18 years old
- Having been involved in at least one swimming style for at least 3 years
- Having participated in at least one competition
- Obtaining parental consent. Obtaining parental consent.
Exclusion Criteria:
- - Having undergone any surgery on the shoulder girdle muscles.
- Having any orthopedic or physical disorder in the shoulder girdle muscles (e.g., frozen shoulder).
- Participating in another sport besides swimming.
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
코호트 및 개입
그룹/코호트 |
개입 / 치료 |
|---|---|
|
Monofin swimmers
|
MyotonPro is used to utilize the biomechanical properties of the muscle.
During measurements, the patient will be seated in a chair with back support; the biomechanical properties of the rectus femoris, tibialis anterior, medial gastrocnemius, and hamstring muscles (F - Natural Oscillation Frequency [Hz], Tone or Tension ranges, S - Dynamic Stiffness [N/m], D - Logarithmic Decrease [relative unit], Elasticity increase, R - Mechanical Stress Relaxation Time [ms], C - Relaxation and Deformation Time Ratio [relaxation and deformation time ratio [N/m]) will be measured bilaterally using Myoton PRO.
All measurements will be tracked according to the mileage.
Swimmers' right and left leg lengths (cm) will be measured.
All measurements will be tracked in terms of kilometers covered.
All measurements will be compared statistically according to pallet types.
Passive range of motion of the lower extremity shoulder joint (flexion, extension, adduction, abduction, external rotation, and internal rotation) will be measured using a digital goniometer.
Results will be recorded in degrees (°).
All measurements will be compared statistically according to pallet types.
|
|
Bi-fin swimmers
|
MyotonPro is used to utilize the biomechanical properties of the muscle.
During measurements, the patient will be seated in a chair with back support; the biomechanical properties of the rectus femoris, tibialis anterior, medial gastrocnemius, and hamstring muscles (F - Natural Oscillation Frequency [Hz], Tone or Tension ranges, S - Dynamic Stiffness [N/m], D - Logarithmic Decrease [relative unit], Elasticity increase, R - Mechanical Stress Relaxation Time [ms], C - Relaxation and Deformation Time Ratio [relaxation and deformation time ratio [N/m]) will be measured bilaterally using Myoton PRO.
All measurements will be tracked according to the mileage.
Swimmers' right and left leg lengths (cm) will be measured.
All measurements will be tracked in terms of kilometers covered.
All measurements will be compared statistically according to pallet types.
Passive range of motion of the lower extremity shoulder joint (flexion, extension, adduction, abduction, external rotation, and internal rotation) will be measured using a digital goniometer.
Results will be recorded in degrees (°).
All measurements will be compared statistically according to pallet types.
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Measuring the biomechanical properties of muscles with MyotonPro
기간: From enrollment to the end of treatment at 6 weeks
|
Bilaterally Biomechanical properties (F - Natural Oscillation Frequency [Hz], characterizing Tone or Tension, S - Dynamic Stiffness [N/m], D - Logarithmic Decrement [relative unit], characterizing Elasticity, R - Mechanical Stress Relaxation Time [ms], C - Ratio of Relaxation and Deformation time [relative unit], characterizing Creep) of the rectus femoris, tibialis anterior, medial gastrocnemius and hamstring muscles were measured using Myoton PRO. Because the MyotonPRO assessment yields a single-session composite outcome by presenting all relevant units concurrently on the screen, these variables were treated as a whole rather than being documented separately. |
From enrollment to the end of treatment at 6 weeks
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Measuring the length of lower extremity using a tape measure.
기간: From enrollment to the end of measurements at 6 weeks.
|
The measuring tape will be used to measure the swimmers' Right and left legs length (cm).
|
From enrollment to the end of measurements at 6 weeks.
|
|
Measuring the range of motion of the lower extremity using a digital goniometer
기간: From enrollment to the end of 6 weeks.
|
Passive range of motion of the lower extremity joints (flexion, extension, adduction, abduction, external rotation, and internal rotation) will be measured using a digital goniometer.
Results will be recorded in degrees (°)
|
From enrollment to the end of 6 weeks.
|
공동 작업자 및 조사자
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
기타 연구 ID 번호
- 27.04.2026-2026/04
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .