- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT07764575
Predictors of Extubation Failure in Ventilated Neonates (Neonates)
연구 개요
상세 설명
Mechanical ventilation (MV) is life-saving in the neonatal intensive care unit (NICU), yet extubation timing remains one of the most consequential and poorly standardized decisions in neonatology. The rate of extubation failure (EF) increases from 20% in infants born at 28-31 weeks gestational age to more than 60% in very preterm infants born at less than 28 weeks gestational age, for several reasons including frequent or severe apneas, residual lung disease, immature respiratory drive, and the presence of an unstable patent ductus arteriosus (PDA) .
EF is defined as the need for reintubation within 72 hours of a planned extubation attempt, and its consequences are profound. EF not only prolongs the duration of MV but is independently associated with increased mortality, morbidity, length of hospital stay, and healthcare costs.
Clinical judgment, personal experience, bedside observation of blood gases, oxygen requirements, and ventilator settings are typically used to make decisions on whenever to extubate or not. Consequently, there are significant practical differences and a paucity of protocols to simplify the management of all components of the peri-extubation process, with decisions often being physician-dependent rather than evidence-based, which may lead to inappropriate extubation.
The emergence of point-of-care ultrasound (POCUS) and targeted neonatal echocardiography (TNE) has created new opportunities for objective, real-time, bedside physiological assessment. Lung ultrasound score (LUS), diaphragmtic thickening fraction (DTF) and excursion, arterial blood gas (ABG) analysis, and functional echocardiographic hemodynamic assessment, including left ventricular outflow tract velocity time integral (LVOT VTI), right ventricular outflow tract (RVOT), and patent ductus arteriosus (PDA) characterization, represent four physiologically independent domains that together capture the full spectrum of mechanisms underlying extubation failure. No validated multimodal bedside scoring tool combining all four domains currently exists in neonatology.
This protocol proposes a prospective observational study to develop and validate such a model, directly addressing a critical evidence gap identified by recent systematic reviews.
연구 유형
등록 (추정된)
참여기준
자격 기준
공부할 수 있는 나이
- 어린이
- 성인
- 고령자
건강한 자원 봉사자를 받아들입니다
샘플링 방법
연구 인구
설명
Inclusion Criteria:
- Neonates (gestational age 28-44 weeks corrected) mechanically ventilated for ≥48 hours
- Planned extubation as determined by the treating neonatologist
- Hemodynamically stable at enrollment
Exclusion Criteria:
- Major congenital anomalies
- Neuromuscular disorders
- Thoracic malformations
- Inborn error of metabolism
- Unplanned/accidental extubation
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
코호트 및 개입
그룹/코호트 |
|---|
|
Extubatuin sucess
Parameters of neonates who will be successed to be weaned
|
|
Extubation failure
Parameters of neonates who will be failed to be weaned
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
The role of functional echocardiography in predicting exutbation failure
기간: baseline
|
The role of functional echocardiography in predicting exutbation failure
|
baseline
|
|
The role of Chest ultrasound in predicting extubation failure
기간: baseline
|
The role of Chest ultrasound in predicting extubation failure
|
baseline
|
|
The role of plasma soluble intercellular adhesion molecule-1 in predicting extubation failure
기간: baseline
|
The role of plasma soluble intercellular adhesion molecule-1 in predicting extubation failure
|
baseline
|
공동 작업자 및 조사자
연구 기록 날짜
연구 주요 날짜
연구 시작 (추정된)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
기타 연구 ID 번호
- Extubation failure
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .