- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT07786610
Spectroscopic Assessment of Tissue Oxygenation Changes in Plastic Surgical Flap Reconstructions
연구 개요
상세 설명
A total of 30 participants aged 18 or older, with a planned plastic surgical reconstructive flap operation, will be recruited in this investigation. The primary purpose is to investigate the ability of the SpectroCor Tissue Oxygenation Monitor and its accessory SpectroCor Sensor to observe and monitor peripheral tissue oxygenation perioperatively. The investigation is designed as an open, non-controlled observational study with the primary goal of assessing the devices' ability to monitor and observe tissue oxygenation and safety in routine operation, reflecting the real-world patient population and treatment scenarios. Therefore, no control group is needed in this investigation.
In this study, the SpectroCor Tissue Oxygenation Monitoring is used to observe flap viability during and after plastic surgical reconstruction. SpectroCor sensor is inserted into the reconstructed flap or into the subcutaneous tissue in the distal wound to observe and collect data on tissue oxygenation. During the procedure, the flap tissue undergoes an ischemic period during microsurgical anastomosis, followed by reperfusion upon release of the vascular clamp. During the reconstructive flap surgery, spectroscopic data of tissue oxygenation are collected and compared to the recorded tissue saturation levels and to occurring events, procedures, and clinical parameters.
연구 유형
등록 (추정된)
연락처 및 위치
연구 연락처
- 이름: Tommi Pätilä, PhD
- 전화번호: +358 440130770
- 이메일: tommi@spectrocor.com
연구 연락처 백업
- 이름: Kalle Kotilahti, PhD
- 전화번호: +358449016550
- 이메일: kalle@spectrocor.com
참여기준
자격 기준
공부할 수 있는 나이
- 성인
- 고령자
건강한 자원 봉사자를 받아들입니다
샘플링 방법
연구 인구
설명
Inclusion Criteria:
- Adults, age of 18 - 90 years
- Scheduled for plastic surgical reconstructive flap operation
- Ability and willingness to provide informed consent.
Exclusion Criteria:
- Unable to provide signed informed consent
- Considered a vulnerable person according to the Finnish Medical Research Act (488/1999), Chapter 2, Sections 7, 9, and 10, including retarded persons, pregnant women, nursing mothers, prisoners, and forensic patients.
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Observe changes in flap tissue oxygenation
기간: From sensor placement until sensor removal minutes before completion of surgery (intraoperative period, approximately 2-6 hours)
|
To observe the changes in flap tissue oxygenation (combined hemoglobin/myoglobin saturation, %) measured by the SpectroCor Monitoring System during the ischemia-reperfusion sequence of microvascular flap reconstruction. Continuous spectroscopic measurement of combined hemoglobin and myoglobin oxygen saturation in the transferred flap tissue, recorded from a SpectroCor Sensor inserted into the flap, with a second sensor placed in subcutaneous tissue of the distal wound. Saturation values are time-stamped against intraoperative events affecting flap perfusion (pedicle division and flap detachment from the donor site, completion of the microvascular anastomosis, release of the vascular clamp and reperfusion, and any anastomotic revision) and compared with paired arterial and venous blood gas samples obtained at the beginning and at the end of the surgery. |
From sensor placement until sensor removal minutes before completion of surgery (intraoperative period, approximately 2-6 hours)
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Incidence of adverse events, adverse device effects, and device deficiencies
기간: From sensor placement during the operation until discharge from hospital (up to 30 days)
|
Number and proportion of participants experiencing at least one adverse event (AE), adverse device effect (ADE), serious adverse event (SAE), serious adverse device effect (SADE), or unanticipated serious adverse device effect (USADE), and the number of device deficiencies (DD) recorded.
Events are recorded from the time of sensor placement until discharge from hospital and assessed for causal relationship to the investigational device by the investigator.
Anticipated device-related events include topical bleeding at the sensor attachment site, local tissue reaction associated with tissue glue fixation, and local infection at the insertion site.
|
From sensor placement during the operation until discharge from hospital (up to 30 days)
|
공동 작업자 및 조사자
스폰서
수사관
- 수석 연구원: Patrik Lassus, PhD, Helsinki University Hospital (HUS)
간행물 및 유용한 링크
일반 간행물
- Ali J, Cody J, Maldonado Y, Ramakrishna H. Near-Infrared Spectroscopy (NIRS) for Cerebral and Tissue Oximetry: Analysis of Evolving Applications. J Cardiothorac Vasc Anesth. 2022 Aug;36(8 Pt A):2758-2766. doi: 10.1053/j.jvca.2021.07.015. Epub 2021 Jul 10.
- Keller A. Noninvasive tissue oximetry for flap monitoring: an initial study. J Reconstr Microsurg. 2007 May;23(4):189-97. doi: 10.1055/s-2007-974655.
- Keller A. A new diagnostic algorithm for early prediction of vascular compromise in 208 microsurgical flaps using tissue oxygen saturation measurements. Ann Plast Surg. 2009 May;62(5):538-43. doi: 10.1097/SAP.0b013e3181a47ce8.
- Steele MH. Three-year experience using near infrared spectroscopy tissue oximetry monitoring of free tissue transfers. Ann Plast Surg. 2011 May;66(5):540-5. doi: 10.1097/SAP.0b013e31820909f9.
- Chen Y, Shen Z, Shao Z, Yu P, Wu J. Free Flap Monitoring Using Near-Infrared Spectroscopy: A Systemic Review. Ann Plast Surg. 2016 May;76(5):590-7. doi: 10.1097/SAP.0000000000000430.
- Tran PC, DeBrock W, Lester ME, Hartman BC, Socas J, Hassanein AH. The False Positive Rate of Transcutaneous Tissue Oximetry Alarms in Microvascular Breast Reconstruction Rises after 24 Hours. J Reconstr Microsurg. 2021 Jun;37(5):453-557. doi: 10.1055/s-0040-1719048. Epub 2020 Oct 31.
- Schoenbrunner A, Hackenberger PN, DeSanto M, Chetta M. Cost-Effectiveness of Vioptix versus Clinical Examination for Flap Monitoring of Autologous Free Tissue Breast Reconstruction. Plast Reconstr Surg. 2021 Aug 1;148(2):185e-189e. doi: 10.1097/PRS.0000000000008154.
- Sultan DL, Atamian E, Tarr J, Feingold R, Kasabian AK, Tanna N, Smith ML, Moon V. A Prospective Cohort Study Re-examining Tissue Oximetry Monitoring in Microsurgical Breast Reconstruction. Ann Plast Surg. 2023 Jun 1;90(6):580-584. doi: 10.1097/SAP.0000000000003555. Epub 2023 May 9.
연구 기록 날짜
연구 주요 날짜
연구 시작 (추정된)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
추가 관련 MeSH 약관
기타 연구 ID 번호
- SpC Flaps
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
IPD 계획 설명
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .