- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT07812649
NIRAF-camera Versus Conventional Surgery in Preoperative Imaging Negative Primary Hyperparathyroidism
Outcomes of Parathyroidectomy Using NIRAF-camera Versus Conventional Surgery in Patients With Preoperative Imaging Negative Primary Hyperparathyroidism: A Randomized Controlled Trial
Primary hyperparathyroidism (PHPT) is a prevalent endocrine disorder, with an estimated prevalence of 0.86% in the United States. The only definitive treatment for PHPT is parathyroidectomy. Preoperative localization of abnormal parathyroid glands (PGs) is typically achieved using ultrasound imaging and 99mTc-sestamibi scans, which aid in surgical planning and reducing intraoperative gland detection time and increasing the likelihood of successful gland identification. However, reported cure rates can be as low as 79.5%, because of the challenges in identifying PGs intraoperatively.
Near-infrared autofluorescence (NIRAF) imaging has recently emerged as a promising adjunctive tool for intraoperative PG identification, particularly in thyroidectomy and parathyroidectomy procedures. It has been FDA-approved as an adjunctive tool for parathyroid identification. NIRAF imaging distinguishes normal PGs, which typically appear bright and homogeneous, from abnormal PGs, which are dim and heterogeneous (Figure). Previous studies have demonstrated that NIRAF-camera technology enhances PG detection during thyroidectomy, leading to improved surgical outcomes and reduced postoperative hypoparathyroidism rates. However, limited research exists regarding its application in parathyroidectomy procedures, with only a few studies suggesting its potential benefits, such as a reduction in the need for frozen sections. At the Cleveland Clinic, parathyroidectomy procedures are done with or without the use of this NIRAF technology, based on surgeon preference and both approaches are considered as part of standard of care.
To date, no study has specifically investigated the use of NIRAF technology in PHPT patients in terms of time to PG detection. Given the challenges associated with localizing abnormal PGs in such cases, further research is warranted to explore the potential of NIRAF imaging in improving surgical outcomes. This is a study, randomizing patients to parathyroidectomy with or without (conventional surgery) NIRAF imaging. Surgeons in the control group (conventional) will not be using the NIRAF camera in the procedures unless he/she/they feel a need to use it based on intraoperative findings and surgeon decision. The conventional surgery patients in whom the surgeon decides to use the camera will continue to be analyzed in the original group, with the intention to treat principle, but these cross overs will be recorded and reported as a data field.
Primary Study Aim: To assess whether NIRAF-Camera helps to decrease the gland detection time in PHPT cases.
Secondary Study Aim: To evaluate the impact of NIRAF-Camera on post-operative cure rates and number of frozen sections done in PHPT cases.
연구 개요
연구 유형
등록 (추정된)
단계
- 해당 없음
연락처 및 위치
연구 장소
-
-
Ohio
-
Cleveland, Ohio, 미국, 44195
- 모병
- Cleveland Clinic
-
연락하다:
- Chaise Brewer
- 전화번호: 216-672-2131
- 이메일: brewerc3@ccf.org
-
수석 연구원:
- Eren Berber
-
-
참여기준
자격 기준
공부할 수 있는 나이
- 성인
- 고령자
건강한 자원 봉사자를 받아들입니다
설명
Inclusion Criteria:
- Diagnosed with primary hyperparathyroidism
- Undergoing bilateral neck exploration
- Will under go only parathyroidectomy surgery
Exclusion Criteria:
- Diagnosed with secondary or tertiary hyperparathyroidism
- Undergoing focal PG exploration
- Will undergo concomitant surgery (total thyroidectomy, thyroid lobectomy)
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 다른
- 할당: 무작위
- 중재 모델: 병렬 할당
- 마스킹: 없음(오픈 라벨)
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
간섭 없음: Conventional Parathyroidectomy (without NIRAF-camera)
|
|
|
활성 비교기: Parathyroidectomy with NIRAF-camera
|
Near-infrared autofluorescence (NIRAF) camera as an adjunctive tool used for intraoperative identification of abnormal parathyroid glands.
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
기간 |
|---|---|
|
Gland detection time
기간: intraoperative
|
intraoperative
|
2차 결과 측정
결과 측정 |
기간 |
|---|---|
|
Cure rates
기간: 2 weeks and 6 months post-op
|
2 weeks and 6 months post-op
|
|
Number of Frozen Sections
기간: intraoperative
|
intraoperative
|
공동 작업자 및 조사자
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
추가 관련 MeSH 약관
기타 연구 ID 번호
- 26-400
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
미국에서 제조되어 미국에서 수출되는 제품
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .