- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT07828431
Comparison of Bond Failure Rate of Orthodontic Brackets Bonded With V-Prep and Resin-Modified Glass Ionomer Cement Versus Conventional Acid-Etch Composite Resin
Comparison of Bond Failure Rate of Orthodontic Brackets Bonded With V-Prep and Resin-Modified Glass Ionomer Cement Versus Conventional Acid-Etch Composite Resin: A Split-Mouth Randomized Controlled Trial
Ethical approval will be obtained by the FUSH and informed consent will be obtained from individual patients/guardians in writing. Inclusion and exclusion criteria will be used to obtain random patient samples within the Orthodontic Department of FUCD&H and Baseline parameters like age, gender, O'Leary Plaque Score, malocclusion classification type and degree of overbite will be recorded. Patients will be screened one at a time if they are eligible. For this purpose, sequentially numbered, opaque sealed envelopes will be opened just before the bonding assignment for allocation concealment. Both orally and in writing to all patients. Tooth surfaces will be pumiced and standardized.
While, the Primer light-cured for 10-sec each item, the Control group (enamel) etched for 30-sec, washed for 15-sec and air dried to a frosty white. The tough brackets will be attached, with a baseline underneath, with a thin layer of composite resin pressed down on optimum. Light cured for 10 seconds on mesial and distal surfaces to remove excess adhesive (STEP 7).
Group II (V-Prep): Enamel surface was were in contact with 0%-1.5% diluted Sodium Hypochlorite during 60 seconds, rinsed and thoroughly dried; then the V-Prep was applied. 37% phosphoric acid gel for 30 Sec, rinsed for 15 Sec and dried until a frost white appearance on the etched enamel area. The first is called Primer and will be light cured for 10 seconds. A template will then be provisionally fixed to secure the bottom of the bracket in place with Resin-Modified Glass Ionomer Cement. Clean of excess adhesive, and cure for 10 seconds mesial and distal.
Then instead of going to bonding, this will be taken out and ligated to a 0.012-in Ni-Ti archwire. Will follow a 30 days interval series of 6 follow-up visits, monthly visits throughout 6 months
연구 개요
상태
상세 설명
Ethical approval will be obtained by the FUSH and informed consent will be obtained from individual patients/guardians in writing. Inclusion and exclusion criteria will be used to obtain random patient samples within the Orthodontic Department of FUCD&H and Baseline parameters like age, gender, O'Leary Plaque Score, malocclusion classification type and degree of overbite will be recorded. Patients will be screened one at a time if they are eligible. For this purpose, sequentially numbered, opaque sealed envelopes will be opened just before the bonding assignment for allocation concealment. Both orally and in writing to all patients. Tooth surfaces will be pumiced and standardized. To minimize inter-operator variability for any of the procedures listed above, all bonding will be completed by a single operator (principal investigator) that has been trained on the trial.
While, the Primer light-cured for 10-sec each item, the Control group (enamel) etched for 30-sec, washed for 15-sec and air dried to a frosty white. The tough brackets will be attached, with a baseline underneath, with a thin layer of composite resin pressed down on optimum. Light cured for 10 seconds on mesial and distal surfaces to remove excess adhesive (STEP 7).
Group II (V-Prep): Enamel surface was were in contact with 0%-1.5% diluted Sodium Hypochlorite during 60 seconds, rinsed and thoroughly dried; then the V-Prep was applied. 37% phosphoric acid gel for 30 Sec, rinsed for 15 Sec and dried until a frost white appearance on the etched enamel area. The first is called Primer and will be light cured for 10 seconds. A template will then be provisionally fixed to secure the bottom of the bracket in place with Resin-Modified Glass Ionomer Cement. Clean of excess adhesive, and cure for 10 seconds mesial and distal Then instead of going to bonding, this will be taken out and ligated to a 0.012-in Ni-Ti archwire. Will follow a 30 days interval series of 6 follow-up visits, monthly visits throughout 6 months
연구 유형
등록 (실제)
단계
- 해당 없음
연락처 및 위치
연구 장소
-
-
Punjab Province
-
Rawalpindi, Punjab Province, 파키스탄, 44000
- Foundation University College of Dentistry and Hospital
-
-
참여기준
자격 기준
공부할 수 있는 나이
- 어린이
- 성인
건강한 자원 봉사자를 받아들입니다
설명
Inclusion Criteria:
- Patients aged 12-18 years
- The extraction was limited to Two arches.
- Functional Overbite/Underbite ( < 50% or 1, 2-3 mm?)
- Malocclusions Class I or II
Exclusion Criteria:
- Class III malocclusion
- Type 2: Facial Osteopathy (Cleft lip or palate)
- The history of allergic reactions to dental materials goes back to 1903.Allergic reactions to dental materials date back to 1903.
- Developmental enamel defects (fluorosis, hypoplasia)
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 치료
- 할당: 무작위
- 중재 모델: 단일 그룹 할당
- 마스킹: 하나의
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
실험적: V-Prep and Resin-Modified Glass Ionomer Cement
V prep with sodium hypochlorite and bonding with RMGIC
|
V-Prep with sodium hypochlorite and bonding with Resin-Modified Glass Ionomer Cement
|
|
활성 비교기: Conventional Acid-Etch Composite Resin
Conventional Composite Resin Bonding
|
Conventional Composite Resin bonding
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Bond Failure Rate of Orthodontic Brackets
기간: 6 months
|
Time-to-failure of orthodontic brackets between the V-Prep and Resin-Modified Glass Ionomer Cement [RMGIC] and conventional 37% phosphoric acid-etch composite resin technique.
|
6 months
|
공동 작업자 및 조사자
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
기타 연구 ID 번호
- FUCD-Ortho- 26
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
IPD 계획 설명
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .