- ICH GCP
- Amerikanska kliniska prövningsregistret
- Klinisk prövning NCT07828431
Comparison of Bond Failure Rate of Orthodontic Brackets Bonded With V-Prep and Resin-Modified Glass Ionomer Cement Versus Conventional Acid-Etch Composite Resin
Comparison of Bond Failure Rate of Orthodontic Brackets Bonded With V-Prep and Resin-Modified Glass Ionomer Cement Versus Conventional Acid-Etch Composite Resin: A Split-Mouth Randomized Controlled Trial
Ethical approval will be obtained by the FUSH and informed consent will be obtained from individual patients/guardians in writing. Inclusion and exclusion criteria will be used to obtain random patient samples within the Orthodontic Department of FUCD&H and Baseline parameters like age, gender, O'Leary Plaque Score, malocclusion classification type and degree of overbite will be recorded. Patients will be screened one at a time if they are eligible. For this purpose, sequentially numbered, opaque sealed envelopes will be opened just before the bonding assignment for allocation concealment. Both orally and in writing to all patients. Tooth surfaces will be pumiced and standardized.
While, the Primer light-cured for 10-sec each item, the Control group (enamel) etched for 30-sec, washed for 15-sec and air dried to a frosty white. The tough brackets will be attached, with a baseline underneath, with a thin layer of composite resin pressed down on optimum. Light cured for 10 seconds on mesial and distal surfaces to remove excess adhesive (STEP 7).
Group II (V-Prep): Enamel surface was were in contact with 0%-1.5% diluted Sodium Hypochlorite during 60 seconds, rinsed and thoroughly dried; then the V-Prep was applied. 37% phosphoric acid gel for 30 Sec, rinsed for 15 Sec and dried until a frost white appearance on the etched enamel area. The first is called Primer and will be light cured for 10 seconds. A template will then be provisionally fixed to secure the bottom of the bracket in place with Resin-Modified Glass Ionomer Cement. Clean of excess adhesive, and cure for 10 seconds mesial and distal.
Then instead of going to bonding, this will be taken out and ligated to a 0.012-in Ni-Ti archwire. Will follow a 30 days interval series of 6 follow-up visits, monthly visits throughout 6 months
Studieöversikt
Status
Betingelser
Intervention / Behandling
Detaljerad beskrivning
Ethical approval will be obtained by the FUSH and informed consent will be obtained from individual patients/guardians in writing. Inclusion and exclusion criteria will be used to obtain random patient samples within the Orthodontic Department of FUCD&H and Baseline parameters like age, gender, O'Leary Plaque Score, malocclusion classification type and degree of overbite will be recorded. Patients will be screened one at a time if they are eligible. For this purpose, sequentially numbered, opaque sealed envelopes will be opened just before the bonding assignment for allocation concealment. Both orally and in writing to all patients. Tooth surfaces will be pumiced and standardized. To minimize inter-operator variability for any of the procedures listed above, all bonding will be completed by a single operator (principal investigator) that has been trained on the trial.
While, the Primer light-cured for 10-sec each item, the Control group (enamel) etched for 30-sec, washed for 15-sec and air dried to a frosty white. The tough brackets will be attached, with a baseline underneath, with a thin layer of composite resin pressed down on optimum. Light cured for 10 seconds on mesial and distal surfaces to remove excess adhesive (STEP 7).
Group II (V-Prep): Enamel surface was were in contact with 0%-1.5% diluted Sodium Hypochlorite during 60 seconds, rinsed and thoroughly dried; then the V-Prep was applied. 37% phosphoric acid gel for 30 Sec, rinsed for 15 Sec and dried until a frost white appearance on the etched enamel area. The first is called Primer and will be light cured for 10 seconds. A template will then be provisionally fixed to secure the bottom of the bracket in place with Resin-Modified Glass Ionomer Cement. Clean of excess adhesive, and cure for 10 seconds mesial and distal Then instead of going to bonding, this will be taken out and ligated to a 0.012-in Ni-Ti archwire. Will follow a 30 days interval series of 6 follow-up visits, monthly visits throughout 6 months
Studietyp
Inskrivning (Faktisk)
Fas
- Inte tillämpbar
Kontakter och platser
Studieorter
-
-
Punjab Province
-
Rawalpindi, Punjab Province, Pakistan, 44000
- Foundation University College of Dentistry and Hospital
-
-
Deltagandekriterier
Urvalskriterier
Åldrar som är berättigade till studier
Tar emot friska volontärer
Kön som är behöriga för studier
Beskrivning
Inclusion Criteria:
- Patients aged 12-18 years
- The extraction was limited to Two arches.
- Functional Overbite/Underbite ( < 50% or 1, 2-3 mm?)
- Malocclusions Class I or II
Exclusion Criteria:
- Class III malocclusion
- Type 2: Facial Osteopathy (Cleft lip or palate)
- The history of allergic reactions to dental materials goes back to 1903.Allergic reactions to dental materials date back to 1903.
- Developmental enamel defects (fluorosis, hypoplasia)
Studieplan
Hur är studien utformad?
Designdetaljer
- Primärt syfte: Behandling
- Tilldelning: Randomiserad
- Interventionsmodell: Enskild gruppuppgift
- Maskning: Enda
Vapen och interventioner
Deltagargrupp / Arm |
Intervention / Behandling |
|---|---|
|
Experimentell: V-Prep and Resin-Modified Glass Ionomer Cement
V prep with sodium hypochlorite and bonding with RMGIC |
V-Prep with sodium hypochlorite and bonding with Resin-Modified Glass Ionomer Cement |
|
Aktiv komparator: Conventional Acid-Etch Composite Resin
Conventional Composite Resin Bonding |
Conventional Composite Resin bonding |
Vad mäter studien?
Primära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
Bond Failure Rate of Orthodontic Brackets
Tidsram: 6 months
|
Time-to-failure of orthodontic brackets between the V-Prep and Resin-Modified Glass Ionomer Cement [RMGIC] and conventional 37% phosphoric acid-etch composite resin technique. |
6 months
|
Samarbetspartners och utredare
Sponsor
Studieavstämningsdatum
Studera stora datum
Studiestart (Faktisk)
Primärt slutförande (Beräknad)
Avslutad studie (Beräknad)
Studieregistreringsdatum
Först inskickad
Först inskickad som uppfyllde QC-kriterierna
Första postat (Faktisk)
Uppdateringar av studier
Senaste uppdatering publicerad (Faktisk)
Senaste inskickade uppdateringen som uppfyllde QC-kriterierna
Senast verifierad
Mer information
Termer relaterade till denna studie
Andra studie-ID-nummer
- FUCD-Ortho- 26
Plan för individuella deltagardata (IPD)
Planerar du att dela individuella deltagardata (IPD)?
IPD-planbeskrivning
University policy to maintain patients confidentiality
Läkemedels- och apparatinformation, studiedokument
Studerar en amerikansk FDA-reglerad läkemedelsprodukt
Studerar en amerikansk FDA-reglerad produktprodukt
Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .