Comparison of Bond Failure Rate of Orthodontic Brackets Bonded With V-Prep and Resin-Modified Glass Ionomer Cement Versus Conventional Acid-Etch Composite Resin
Comparison of Bond Failure Rate of Orthodontic Brackets Bonded With V-Prep and Resin-Modified Glass Ionomer Cement Versus Conventional Acid-Etch Composite Resin: A Split-Mouth Randomized Controlled Trial
Ethical approval will be obtained by the FUSH and informed consent will be obtained from individual patients/guardians in writing. Inclusion and exclusion criteria will be used to obtain random patient samples within the Orthodontic Department of FUCD&H and Baseline parameters like age, gender, O'Leary Plaque Score, malocclusion classification type and degree of overbite will be recorded. Patients will be screened one at a time if they are eligible. For this purpose, sequentially numbered, opaque sealed envelopes will be opened just before the bonding assignment for allocation concealment. Both orally and in writing to all patients. Tooth surfaces will be pumiced and standardized.
While, the Primer light-cured for 10-sec each item, the Control group (enamel) etched for 30-sec, washed for 15-sec and air dried to a frosty white. The tough brackets will be attached, with a baseline underneath, with a thin layer of composite resin pressed down on optimum. Light cured for 10 seconds on mesial and distal surfaces to remove excess adhesive (STEP 7).
Group II (V-Prep): Enamel surface was were in contact with 0%-1.5% diluted Sodium Hypochlorite during 60 seconds, rinsed and thoroughly dried; then the V-Prep was applied. 37% phosphoric acid gel for 30 Sec, rinsed for 15 Sec and dried until a frost white appearance on the etched enamel area. The first is called Primer and will be light cured for 10 seconds. A template will then be provisionally fixed to secure the bottom of the bracket in place with Resin-Modified Glass Ionomer Cement. Clean of excess adhesive, and cure for 10 seconds mesial and distal.
Then instead of going to bonding, this will be taken out and ligated to a 0.012-in Ni-Ti archwire. Will follow a 30 days interval series of 6 follow-up visits, monthly visits throughout 6 months
研究概览
地位
详细说明
Ethical approval will be obtained by the FUSH and informed consent will be obtained from individual patients/guardians in writing. Inclusion and exclusion criteria will be used to obtain random patient samples within the Orthodontic Department of FUCD&H and Baseline parameters like age, gender, O'Leary Plaque Score, malocclusion classification type and degree of overbite will be recorded. Patients will be screened one at a time if they are eligible. For this purpose, sequentially numbered, opaque sealed envelopes will be opened just before the bonding assignment for allocation concealment. Both orally and in writing to all patients. Tooth surfaces will be pumiced and standardized. To minimize inter-operator variability for any of the procedures listed above, all bonding will be completed by a single operator (principal investigator) that has been trained on the trial.
While, the Primer light-cured for 10-sec each item, the Control group (enamel) etched for 30-sec, washed for 15-sec and air dried to a frosty white. The tough brackets will be attached, with a baseline underneath, with a thin layer of composite resin pressed down on optimum. Light cured for 10 seconds on mesial and distal surfaces to remove excess adhesive (STEP 7).
Group II (V-Prep): Enamel surface was were in contact with 0%-1.5% diluted Sodium Hypochlorite during 60 seconds, rinsed and thoroughly dried; then the V-Prep was applied. 37% phosphoric acid gel for 30 Sec, rinsed for 15 Sec and dried until a frost white appearance on the etched enamel area. The first is called Primer and will be light cured for 10 seconds. A template will then be provisionally fixed to secure the bottom of the bracket in place with Resin-Modified Glass Ionomer Cement. Clean of excess adhesive, and cure for 10 seconds mesial and distal Then instead of going to bonding, this will be taken out and ligated to a 0.012-in Ni-Ti archwire. Will follow a 30 days interval series of 6 follow-up visits, monthly visits throughout 6 months
研究类型
注册 (实际的)
阶段
- 不适用
联系人和位置
学习地点
-
-
Punjab Province
-
Rawalpindi、Punjab Province、巴基斯坦、44000
- Foundation University College of Dentistry and Hospital
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- Patients aged 12-18 years
- The extraction was limited to Two arches.
- Functional Overbite/Underbite ( < 50% or 1, 2-3 mm?)
- Malocclusions Class I or II
Exclusion Criteria:
- Class III malocclusion
- Type 2: Facial Osteopathy (Cleft lip or palate)
- The history of allergic reactions to dental materials goes back to 1903.Allergic reactions to dental materials date back to 1903.
- Developmental enamel defects (fluorosis, hypoplasia)
学习计划
研究是如何设计的?
设计细节
- 主要用途:治疗
- 分配:随机化
- 介入模型:单组作业
- 屏蔽:单身的
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:V-Prep and Resin-Modified Glass Ionomer Cement
V prep with sodium hypochlorite and bonding with RMGIC |
V-Prep with sodium hypochlorite and bonding with Resin-Modified Glass Ionomer Cement |
|
有源比较器:Conventional Acid-Etch Composite Resin
Conventional Composite Resin Bonding |
Conventional Composite Resin bonding |
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Bond Failure Rate of Orthodontic Brackets
大体时间:6 months
|
Time-to-failure of orthodontic brackets between the V-Prep and Resin-Modified Glass Ionomer Cement [RMGIC] and conventional 37% phosphoric acid-etch composite resin technique. |
6 months
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- FUCD-Ortho- 26
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
IPD 计划说明
University policy to maintain patients confidentiality
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.