A Transparent Method for Step Detection using an Acceleration Threshold
Scott W Ducharme, Jongil Lim, Michael A Busa, Elroy J Aguiar, Christopher C Moore, John M Schuna Jr, Tiago V Barreira, John Staudenmayer, Stuart R Chipkin, Catrine Tudor-Locke, Scott W Ducharme, Jongil Lim, Michael A Busa, Elroy J Aguiar, Christopher C Moore, John M Schuna Jr, Tiago V Barreira, John Staudenmayer, Stuart R Chipkin, Catrine Tudor-Locke
Abstract
Step-based metrics provide simple measures of ambulatory activity, yet device software either includes undisclosed proprietary step detection algorithms or simply do not compute step-based metrics. We aimed to develop and validate a simple algorithm to accurately detect steps across various ambulatory and non-ambulatory activities. Seventy-five adults (21-39 years) completed seven simulated activities of daily living (e.g., sitting, vacuuming, folding laundry) and an incremental treadmill protocol from 0.22-2.2ms-1. Directly observed steps were hand-tallied. Participants wore GENEActiv and ActiGraph accelerometers, one of each on their waist and on their non-dominant wrist. Raw acceleration (g) signals from the anterior-posterior, medial-lateral, vertical, and vector magnitude (VM) directions were assessed separately for each device. Signals were demeaned across all activities and bandpass filtered [0.25, 2.5Hz]. Steps were detected via peak picking, with optimal thresholds (i.e., minimized absolute error from accumulated hand counted) determined by iterating minimum acceleration values to detect steps. Step counts were converted into cadence (steps/minute), and k-fold cross-validation quantified error (root mean squared error [RMSE]). We report optimal thresholds for use of either device on the waist (threshold=0.0267g) and wrist (threshold=0.0359g) using the VM signal. These thresholds yielded low error for the waist (RMSE<173 steps, ≤2.28 steps/minute) and wrist (RMSE<481 steps, ≤6.47 steps/minute) across all activities, and outperformed ActiLife's proprietary algorithm (RMSE=1312 and 2913 steps, 17.29 and 38.06 steps/minute for the waist and wrist, respectively). The thresholds reported herein provide a simple, transparent framework for step detection using accelerometers during treadmill ambulation and activities of daily living for waist- and wrist-worn locations.
Keywords: accelerometer; physical activity; physical activity monitor; step algorithm; wearable devices.
Figures


Source: PubMed
다가오는 임상 시험
-
Magnus MedicalCongressionally Directed Medical Research Programs모병
-
Nicholas ButowskiSiren Biotechnology아직 모집하지 않음신경교종 | 뇌종양 | 재발성 고등급 신경교종미국
-
State University of New York at Buffalo아직 모집하지 않음
-
Poitiers University Hospital아직 모집하지 않음
-
Assistance Publique - Hôpitaux de Paris아직 모집하지 않음
-
University of California, Irvine모병뇌암 | CNS 암 | 신경계 암 | 뇌전이암미국
-
Guangdong Raynovent Biotech Co., Ltd아직 모집하지 않음
-
The Hong Kong Polytechnic UniversityWu Jieh Yee Charitable Foundation모병
-
Shanghai General Hospital, Shanghai Jiao Tong University...아직 모집하지 않음
-
Sun Yat-sen University아직 모집하지 않음금연 | AI 에이전트 | Early-Stage Cancer
-
Affiliated Hospital of Nantong University아직 모집하지 않음