A Transparent Method for Step Detection using an Acceleration Threshold
Scott W Ducharme, Jongil Lim, Michael A Busa, Elroy J Aguiar, Christopher C Moore, John M Schuna Jr, Tiago V Barreira, John Staudenmayer, Stuart R Chipkin, Catrine Tudor-Locke, Scott W Ducharme, Jongil Lim, Michael A Busa, Elroy J Aguiar, Christopher C Moore, John M Schuna Jr, Tiago V Barreira, John Staudenmayer, Stuart R Chipkin, Catrine Tudor-Locke
Abstract
Step-based metrics provide simple measures of ambulatory activity, yet device software either includes undisclosed proprietary step detection algorithms or simply do not compute step-based metrics. We aimed to develop and validate a simple algorithm to accurately detect steps across various ambulatory and non-ambulatory activities. Seventy-five adults (21-39 years) completed seven simulated activities of daily living (e.g., sitting, vacuuming, folding laundry) and an incremental treadmill protocol from 0.22-2.2ms-1. Directly observed steps were hand-tallied. Participants wore GENEActiv and ActiGraph accelerometers, one of each on their waist and on their non-dominant wrist. Raw acceleration (g) signals from the anterior-posterior, medial-lateral, vertical, and vector magnitude (VM) directions were assessed separately for each device. Signals were demeaned across all activities and bandpass filtered [0.25, 2.5Hz]. Steps were detected via peak picking, with optimal thresholds (i.e., minimized absolute error from accumulated hand counted) determined by iterating minimum acceleration values to detect steps. Step counts were converted into cadence (steps/minute), and k-fold cross-validation quantified error (root mean squared error [RMSE]). We report optimal thresholds for use of either device on the waist (threshold=0.0267g) and wrist (threshold=0.0359g) using the VM signal. These thresholds yielded low error for the waist (RMSE<173 steps, ≤2.28 steps/minute) and wrist (RMSE<481 steps, ≤6.47 steps/minute) across all activities, and outperformed ActiLife's proprietary algorithm (RMSE=1312 and 2913 steps, 17.29 and 38.06 steps/minute for the waist and wrist, respectively). The thresholds reported herein provide a simple, transparent framework for step detection using accelerometers during treadmill ambulation and activities of daily living for waist- and wrist-worn locations.
Keywords: accelerometer; physical activity; physical activity monitor; step algorithm; wearable devices.
Figures


Source: PubMed
Nadchodzące badania kliniczne
-
Shirley Ryan AbilityLabKiwanis Neurological Research FoundationRekrutacyjnyUrazowe uszkodzenie mózgu TBIStany Zjednoczone
-
University of ChicagoNational Heart, Lung, and Blood Institute (NHLBI)Jeszcze nie rekrutacjaŻylna choroba zakrzepowo-zatorowa | Operacja miednicy | Chirurgia raka jamy brzusznejStany Zjednoczone
-
Fundacion para la Investigacion Biomedica del Hospital...Hospital Universitario La FeRekrutacyjny
-
Lumetry Diagnostics GmbHKarl Landsteiner Institute for Lung Research and Pneumological Oncology; Klinik...Jeszcze nie rekrutacjaChoroba płuc, przewlekła obturacja | HiperkapniaAustria
-
Beijing Suncadia Pharmaceuticals Co., LtdRekrutacyjny
-
IpsenJeszcze nie rekrutacja
-
Xiangya Hospital of Central South UniversityJeszcze nie rekrutacjaŁuszczyca plackowata | DyslipidemiaChiny
-
Halic UniversityJeszcze nie rekrutacjaJakość snu | Interwencja dietetyczna | Postrzegany stres | Zaćmienie mózguTurcja (Türkiye)
-
Sun Yat-Sen Memorial Hospital of Sun Yat-Sen UniversityJeszcze nie rekrutacjaRak piersi z przerzutami | Rak piersi z dodatnim receptorem hormonalnym | Rak piersi z niskim HER2Chiny
-
The 108 Military Central HospitalVietnam Military Medical University; Thanh Phuong Co., LtdJeszcze nie rekrutacjaWstrząs septyczny | Ostre uszkodzenie nerekWietnam
-
University Hospital, MontpellierJeszcze nie rekrutacjaNiedowład połowiczy | Spastyczność | Spastyczność kończyn górnychFrancja
-
Kasr El Aini HospitalRekrutacyjnyIdiopatyczne ziarniniakowe zapalenie sutkaEgipt