A Transparent Method for Step Detection using an Acceleration Threshold
Scott W Ducharme, Jongil Lim, Michael A Busa, Elroy J Aguiar, Christopher C Moore, John M Schuna Jr, Tiago V Barreira, John Staudenmayer, Stuart R Chipkin, Catrine Tudor-Locke, Scott W Ducharme, Jongil Lim, Michael A Busa, Elroy J Aguiar, Christopher C Moore, John M Schuna Jr, Tiago V Barreira, John Staudenmayer, Stuart R Chipkin, Catrine Tudor-Locke
Abstract
Step-based metrics provide simple measures of ambulatory activity, yet device software either includes undisclosed proprietary step detection algorithms or simply do not compute step-based metrics. We aimed to develop and validate a simple algorithm to accurately detect steps across various ambulatory and non-ambulatory activities. Seventy-five adults (21-39 years) completed seven simulated activities of daily living (e.g., sitting, vacuuming, folding laundry) and an incremental treadmill protocol from 0.22-2.2ms-1. Directly observed steps were hand-tallied. Participants wore GENEActiv and ActiGraph accelerometers, one of each on their waist and on their non-dominant wrist. Raw acceleration (g) signals from the anterior-posterior, medial-lateral, vertical, and vector magnitude (VM) directions were assessed separately for each device. Signals were demeaned across all activities and bandpass filtered [0.25, 2.5Hz]. Steps were detected via peak picking, with optimal thresholds (i.e., minimized absolute error from accumulated hand counted) determined by iterating minimum acceleration values to detect steps. Step counts were converted into cadence (steps/minute), and k-fold cross-validation quantified error (root mean squared error [RMSE]). We report optimal thresholds for use of either device on the waist (threshold=0.0267g) and wrist (threshold=0.0359g) using the VM signal. These thresholds yielded low error for the waist (RMSE<173 steps, ≤2.28 steps/minute) and wrist (RMSE<481 steps, ≤6.47 steps/minute) across all activities, and outperformed ActiLife's proprietary algorithm (RMSE=1312 and 2913 steps, 17.29 and 38.06 steps/minute for the waist and wrist, respectively). The thresholds reported herein provide a simple, transparent framework for step detection using accelerometers during treadmill ambulation and activities of daily living for waist- and wrist-worn locations.
Keywords: accelerometer; physical activity; physical activity monitor; step algorithm; wearable devices.
Figures


Source: PubMed
Tulevat kliiniset tutkimukset
-
Odense University HospitalEi vielä rekrytointia
-
AbbVieRekrytointi
-
The University of Texas Health Science Center,...National Institute of Neurological Disorders and Stroke (NINDS)Rekrytointi
-
Jørgen Bjerggaard JensenHospital of Southern Jutland; Queen Ingrid's Hospital; MicroPort Medical BV; Ilisimatusarfik - University of GreenlandEi vielä rekrytointia
-
Shanghai Mental Health CenterThe First Affiliated Hospital of Nanchang University; The First Affiliated...Rekrytointi
-
Beijing Chao Yang HospitalEi vielä rekrytointiaPeräsuolen syöpäKiina
-
Selcuk UniversityEi vielä rekrytointiaEnnenaikainen synnytys uhattunaTurkki (Türkiye)
-
University Health Network, TorontoEi vielä rekrytointia
-
Yini WangEi vielä rekrytointia
-
UMMUHAN BAS ASLANRekrytointiLihavuus | YlipainoinenTurkki (Türkiye)
-
King Edward Medical UniversityEi vielä rekrytointiaHIE - Hypoksinen - Iskeeminen enkefalopatia | Hypoksinen-iskeeminen enkefalopatia, vastasyntyneenä | Hypoksinen-iskeeminen enkefalopatia (HIE)
-
Centre Hospitalier Universitaire DijonEi vielä rekrytointia