A Transparent Method for Step Detection using an Acceleration Threshold
Scott W Ducharme, Jongil Lim, Michael A Busa, Elroy J Aguiar, Christopher C Moore, John M Schuna Jr, Tiago V Barreira, John Staudenmayer, Stuart R Chipkin, Catrine Tudor-Locke, Scott W Ducharme, Jongil Lim, Michael A Busa, Elroy J Aguiar, Christopher C Moore, John M Schuna Jr, Tiago V Barreira, John Staudenmayer, Stuart R Chipkin, Catrine Tudor-Locke
Abstract
Step-based metrics provide simple measures of ambulatory activity, yet device software either includes undisclosed proprietary step detection algorithms or simply do not compute step-based metrics. We aimed to develop and validate a simple algorithm to accurately detect steps across various ambulatory and non-ambulatory activities. Seventy-five adults (21-39 years) completed seven simulated activities of daily living (e.g., sitting, vacuuming, folding laundry) and an incremental treadmill protocol from 0.22-2.2ms-1. Directly observed steps were hand-tallied. Participants wore GENEActiv and ActiGraph accelerometers, one of each on their waist and on their non-dominant wrist. Raw acceleration (g) signals from the anterior-posterior, medial-lateral, vertical, and vector magnitude (VM) directions were assessed separately for each device. Signals were demeaned across all activities and bandpass filtered [0.25, 2.5Hz]. Steps were detected via peak picking, with optimal thresholds (i.e., minimized absolute error from accumulated hand counted) determined by iterating minimum acceleration values to detect steps. Step counts were converted into cadence (steps/minute), and k-fold cross-validation quantified error (root mean squared error [RMSE]). We report optimal thresholds for use of either device on the waist (threshold=0.0267g) and wrist (threshold=0.0359g) using the VM signal. These thresholds yielded low error for the waist (RMSE<173 steps, ≤2.28 steps/minute) and wrist (RMSE<481 steps, ≤6.47 steps/minute) across all activities, and outperformed ActiLife's proprietary algorithm (RMSE=1312 and 2913 steps, 17.29 and 38.06 steps/minute for the waist and wrist, respectively). The thresholds reported herein provide a simple, transparent framework for step detection using accelerometers during treadmill ambulation and activities of daily living for waist- and wrist-worn locations.
Keywords: accelerometer; physical activity; physical activity monitor; step algorithm; wearable devices.
Figures


Source: PubMed
Kommende kliniske forsøg
-
Shirley Ryan AbilityLabKiwanis Neurological Research FoundationRekrutteringTBI Traumatisk hjerneskadeForenede Stater
-
University of ChicagoNational Heart, Lung, and Blood Institute (NHLBI)Ikke rekrutterer endnuVenøs tromboembolisme | Bækkenkirurgi | Abdominal cancer kirurgiForenede Stater
-
Fundacion para la Investigacion Biomedica del Hospital...Hospital Universitario La FeRekruttering
-
Lumetry Diagnostics GmbHKarl Landsteiner Institute for Lung Research and Pneumological Oncology; Klinik FloridsdorfIkke rekrutterer endnuLungesygdom, kronisk obstruktiv | HyperkapniØstrig
-
Beijing Suncadia Pharmaceuticals Co., LtdRekruttering
-
IpsenIkke rekrutterer endnu
-
Xiangya Hospital of Central South UniversityIkke rekrutterer endnuPlaque Psoriasis | DyslipidæmiKina
-
Halic UniversityIkke rekrutterer endnuSøvnkvalitet | Diætintervention | Opfattet stress | HjernetågeTyrkiet (Türkiye)
-
Sun Yat-Sen Memorial Hospital of Sun Yat-Sen UniversityIkke rekrutterer endnuMetastatisk brystkræft | Hormonreceptor-positiv brystkræft | HER2-lav brystkræftKina
-
The 108 Military Central HospitalVietnam Military Medical University; Thanh Phuong Co., LtdIkke rekrutterer endnuSeptisk chok | Akut nyreskadeVietnam
-
University Hospital, MontpellierIkke rekrutterer endnuHemiparese | Spasticitet | Spasticitet i den øvre ekstremitetFrankrig
-
Kasr El Aini HospitalRekrutteringIdiopatisk granulomatøs mastitisEgypten