Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

Inferior Vena Cava Compliance in Trans-thoracic Echocardiography: is the Trans-hepatic Window as Reliable as the Subcostal One

9 november 2021 bijgewerkt door: Denis SCHMARTZ, Brugmann University Hospital

The ability to assess intravascular volume is an essential part of perioperative care: insufficient intravascular volume can result in decreased oxygen delivery to tissues and organ dysfunction, while fluid overload can contribute to the development of oedema, organ dysfunction, respiratory failure and healing defect.

At the present state, there are many different methods of interpreting intravascular circulating blood volume. Non-invasive techniques such as the Clear Sight System, and the transthoracic echocardiogram (TTE) have been proposed as non-invasive methods to assess patient' blood volume.

The aim of this study is to assess whether the measure of the inferior vena cava (IVC) in the trans-hepatic window is as reliable as in the subcostal window to determine fluid responsiveness in perioperative patients. In this study, preload increase will be obtained through passive leg raising. Sensibility and specificity of the two echocardiographic approaches to predict fluid responsiveness will be compared while using the subcostal window as the "gold standard". The effect of passive leg elevation on patient's cardiac output response will be assessed with two different non-invasive techniques: the Clear Sight system and the TTE.

Studie Overzicht

Gedetailleerde beschrijving

The ability to assess intravascular volume is an essential part of perioperative care: insufficient intravascular volume can result in decreased oxygen delivery to tissues and organ dysfunction, while fluid overload can contribute to the development of oedema, organ dysfunction, respiratory failure and healing defect.

Assessment of the volume status in perioperative patients relies on two important concepts: euvolemia and fluid responsiveness.

Euvolemia describes a state of adequate circulating blood volume that allows suitable filling of the cardiac chambers making possible for the heart to produce a cardiac output that meets the peripheral oxygen demand.

Fluid responsiveness describes the ability of the heart to adapt blood flow in response to preload increase.

As euvolemia is the ultimate goal of fluid administration then evaluating fluid responsiveness reflects the process of working toward establishing euvolemia.

At the present state, there are many different methods of interpreting intravascular circulating blood volume: those related to pressures measurements: the central venous pressure (CVP), the pulmonary artery occluded pressure (PAOP), and those related to cardiac output measurements like thermodilution and pulse contour techniques. It is worth noting that all these are invasive methods that expose patients to a series of possible side effects such as: pneumothorax, infections, hematomas and vascular lesions. Non-invasive techniques such as the Clear Sight System, and the transthoracic echocardiogram (TTE) have been proposed as non-invasive methods to assess patient' blood volume.

TTE is a widely used and validated imaging technique which involves the study of the heart and great vessels through multiple examination windows.

In particular, the subcostal window represents the gold standard for evaluating the diameter of the inferior vena cava (IVC) and its compliance, allowing the physician to obtain valuable information on the volume status of patients: several studies have reported that these measurements could predict accurately the hemodynamic response of patient to a change in cardiac preload. However, acquiring images in the subcostal window can be, in some cases, difficult or impossible due to the presence of drainages or surgical wounds; in such cases an alternative could be represented by the trans-hepatic window which, at the best of the investigator's knowledge, it has never been validated in the literature.

The Clear Sight System is a non-invasive blood pressure (BP) monitoring system, where the CO is determined analysing the photo-plethysmography curve by a miniaturized pressure cuff and infrared LEDs.

Its main advantage is to assess CO continuously in a completely non-invasive way, following its variations and thereby contributing to the detection of hypovolaemia. Other visualized parameters are: the stroke volume (SV), the systemic vascular resistance (SVR) as well as the BP and the heart rate (HR).

Passive leg raising (PLR) is a test developed to predict patient's hemodynamic response to increase preload without any fluid administration. Raising the patient from a semi-recumbent position to a position with the head at 0° and the legs raised to a 45° angle is associated with about 300 ml of blood volume mobilization from the lower limbs and splanchnic territory to the central compartment resulting in increased venous return to the heart. This manoeuvre provokes a preload increase to which patients could respond with (responder) or without (non-responders) an augmentation of their cardiac output.

The aim of this study is to assess whether the measure of the IVC in the trans-hepatic window is as reliable as in the subcostal window to determine fluid responsiveness in perioperative patients. In this study, preload increase will be obtained through passive leg raising. Sensibility and specificity of the two echocardiographic approaches to predict fluid responsiveness will be compared while using the subcostal window as the "gold standard". The effect of passive leg elevation on patient's cardiac output response will be assessed with two different non-invasive techniques: the Clear Sight system and the TTE.

Studietype

Ingrijpend

Inschrijving (Werkelijk)

53

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

      • Brussels, België, 1020
        • CHU Brugmann

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

18 jaar en ouder (Volwassen, Oudere volwassene)

Accepteert gezonde vrijwilligers

Nee

Geslachten die in aanmerking komen voor studie

Allemaal

Beschrijving

Inclusion Criteria:

All patients of the CHU Brugmann hospital, who have given their consent, aged over 18 years, with a sinus rhythm, requiring a surgical procedure that allows obtaining high quality TTE imaging without pain and discomfort.

Examples of such surgeries are:

  • Orthopaedic surgery: interventions of upper limbs.
  • Stomatology: dental extractions
  • Gastroenterology: oesophagus gastroscopy
  • Maxillo-facial surgery: septoplasties, rhinoplasties, Le Fort surgeries
  • ENT surgery: thyroidectomy, sleep endoscopies
  • Gynaecology: hysteroscopy, voluntary terminations of pregnancy
  • Ophthalmic surgery

Exclusion Criteria:

  • Refusal to participate to the study
  • suboptimal image acquisition
  • atrial fibrillation, patients with 6 or more extra systoles per minute
  • cardiac valvular pathologies
  • TTE imaging causing pain and/or discomfort to the patient
  • surgeries that don't allow obtaining high quality imaging, elevated intra-abdominal pressure.

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Diagnostisch
  • Toewijzing: NVT
  • Interventioneel model: Opdracht voor een enkele groep
  • Masker: Geen (open label)

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Experimenteel: Surgery
All patients, who have given their consent, aged over 18 years, with a sinus rhythm, requiring a surgical procedure that allows obtaining high quality transthoracic echocardiogram imaging without pain and discomfort.
Transthoracic echocardiogram (TTE) is a widely used and validated imaging technique which involves the study of the heart and great vessels through multiple examination windows. In particular, the subcostal window represents the gold standard for evaluating the diameter of the inferior vena cava (IVC) and its compliance, allowing the physician to obtain valuable information on the volume status of patients. Acquiring images in the subcostal window with a transthoracic echocardiogram (TTE) can be, in some cases, difficult or impossible due to the presence of drainages or surgical wounds: in such cases an alternative could be represented by the trans-hepatic window. This has not been validated in the scientific litterature.

The Clear Sight System is a non-invasive blood pressure (BP) monitoring system, where the CO is determined analysing the photo-plethysmography curve by a miniaturized pressure cuff and infrared LEDs.

Its main advantage is to assess CO continuously in a completely non-invasive way, following its variations and thereby contributing to the detection of hypovolaemia. Other visualized parameters are: the stroke volume (SV), the systemic vascular resistance (SVR) as well as the BP and the heart rate (HR).

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Difference of sensitivity between the trans-hepatic window versus the subcostal window with TTE
Tijdsspanne: 20 minutes
Comparison of the sensitivity of both the trans-hepatic window and the subcostal window to predict the cardiac output response by transthoracic echocardiogram (TTE) to passive leg raising.
20 minutes
Difference of specificity between the trans-hepatic window versus the subcostal window with TTE
Tijdsspanne: 20 minutes
Comparison of the specificity of both the trans-hepatic window and the subcostal window to predict the cardiac output response by transthoracic echocardiogram (TTE) to passive leg raising.
20 minutes

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Difference of sensitivity between the trans-hepatic window versus the subcostal window with the Clear Sight system
Tijdsspanne: 20 minutes
Comparison of the sensitivity and specificity of both the trans-hepatic window and the subcostal window to predict the cardiac output response (with the Clear Sight system) to passive leg raising.
20 minutes
Difference of specificity between the trans-hepatic window versus the subcostal window with the Clear Sight system
Tijdsspanne: 20 minutes
Comparison of the sensitivity and specificity of both the trans-hepatic window and the subcostal window to predict the cardiac output response (with the Clear Sight system) to passive leg raising.
20 minutes
Right atrial pressure (RA)- trans-hepatic window
Tijdsspanne: 20 minutes
Evaluation of the estimation of RA pressure obtained with the trans-hepatic and sub-costal approaches
20 minutes
Right atrial pressure (RA) - subcostal window
Tijdsspanne: 20 minutes
Evaluation of the estimation of RA pressure obtained with the trans-hepatic and sub-costal approaches
20 minutes
Cardiac output
Tijdsspanne: 20 minutes
Cardiac output calculated by: CO= sub-Aortic Velocity Time Integral (sAoVTI) × heart rate in beats per minute (bpm) × left ventricular outflow track (LVOT)
20 minutes

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Onderzoekers

  • Hoofdonderzoeker: Francesco Zuccarini, CHU Brugmann

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

25 juni 2021

Primaire voltooiing (Werkelijk)

30 oktober 2021

Studie voltooiing (Werkelijk)

9 november 2021

Studieregistratiedata

Eerst ingediend

26 april 2021

Eerst ingediend dat voldeed aan de QC-criteria

28 april 2021

Eerst geplaatst (Werkelijk)

29 april 2021

Updates van studierecords

Laatste update geplaatst (Werkelijk)

10 november 2021

Laatste update ingediend die voldeed aan QC-criteria

9 november 2021

Laatst geverifieerd

1 november 2021

Meer informatie

Termen gerelateerd aan deze studie

Andere studie-ID-nummers

  • CHUB-WICAVE

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

NEE

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren