The Use of White Noise and Quiet Time During Labor (White & Quiet)
The Effect of White Noise and Quiet Time Interventions During Labor on Labor Pain, Stress, and Satisfaction
Childbirth is defined as the process in which the fetus and its appendages are expelled from the uterus. The World Health Organization emphasizes that women should have a positive childbirth experience and recommends interventions that reduce pain and stress while increasing maternal satisfaction.
White noise, defined as continuous and monotonous sounds such as wave, water, or wind sounds, and quiet time, described as periods in which environmental noise is minimized, have been shown to reduce pain and stress and improve satisfaction in various patient groups. However, there is a lack of evidence regarding their effects during labor.
Therefore, this study was planned to evaluate the effects of white noise and quiet time interventions applied during labor on perceived labor pain, stress levels, and childbirth satisfaction.
Studie Overzicht
Toestand
Interventie / Behandeling
Gedetailleerde beschrijving
Childbirth is defined as a process in which the fetus and its appendages are expelled from the uterus. The World Health Organization emphasizes that women should have a positive childbirth experience. During childbirth, care providers are recommended to implement interventions that reduce women's pain and stress and increase satisfaction.
White noise is defined as continuous and monotonous sounds such as wave, water, and wind sounds. It has been studied in postoperative patients, infants, and neonates.
Quiet time is defined as a period in which environmental sounds are minimized. It has been studied in postpartum women, patients in acute care units, nurses working in neonatal intensive care units, and infants.
White noise and quiet time interventions have been found to be methods used to reduce pain and stress and to increase satisfaction. However, no study has been found that evaluates the effects of white noise and quiet time interventions on pain, stress, and satisfaction during the childbirth process. Therefore, this study was planned to evaluate the effects of white noise and quiet time interventions applied during childbirth on the level of perceived labor pain, stress level, and childbirth satisfaction.
Studietype
Inschrijving (Werkelijk)
Contacten en locaties
Studie Locaties
-
-
-
Istanbul, Turkije (Türkiye)
- Esenler Women's and Children's Diseases Hospital
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Volwassen
Accepteert gezonde vrijwilligers
Bemonsteringsmethode
Studie Bevolking
Beschrijving
Inclusion Criteria:
Pregnant women aged 18-35 years Pregnant women without a diagnosis of high-risk pregnancy Pregnant women with a gestational age between 37-42 weeks Pregnant women who will have a vaginal delivery Pregnant women in the active phase of labor Pregnant women who can speak or understand Turkish Pregnant women carrying a singleton fetus Primiparous women
Exclusion Criteria:
Pregnant women in the latent phase of labor Pregnant women with hearing impairment Pregnant women who are illiterate Pregnant women with an indication for cesarean section Multiparous women
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
Cohorten en interventies
Groep / Cohort |
Interventie / Behandeling |
|---|---|
|
White Noise Group
Participants received white noise via Bluetooth headphones during active labor at 6 cm and 8 cm cervical dilation (15 minutes each, 50-65 dB).
Pain and stress were assessed using VAS, and maternal satisfaction was evaluated postpartum.
|
Participants received white noise intervention during the active phase of labor. At 4 cm cervical dilation, informed consent was obtained and baseline assessments including Demographic Information Form, Visual Analogue Scale (VAS) for pain, and Visual Analogue Scale for stress were completed. Routine care was provided. At 6 cm and 8 cm cervical dilation, participants were exposed to white noise (50-65 dB) via Bluetooth headphones for 15 minutes each session. Routine monitoring and standard obstetric care were continued. After interventions, pain and stress were reassessed using VAS. At the second postpartum hour, maternal satisfaction was assessed using the Maternal Satisfaction in Childbirth Scale. |
|
Quiet Time Group
At the beginning of the active phase (when cervical dilation was 4 cm), the participant was informed about the study and informed consent was obtained. The Demographic Information Form was completed, and pain was assessed using the Visual Analogue Scale (VAS), while stress was evaluated using a Visual Analogue Scale (VAS). Routine monitoring and standard care were provided. At 6 cm cervical dilation during the active phase, quiet time was provided for 15 minutes using Polter headphones. Routine monitoring and standard care were continued. At 8 cm cervical dilation during the active phase, quiet time was again provided for 15 minutes using Polter headphones. Routine monitoring and standard care were continued. After the intervention, pain was assessed using the Visual Analogue Scale (VAS), and stress was evaluated using a Visual Analogue Scale (VAS). At the second hour postpartum, the Maternal Satisfaction in Childbirth Scale was completed. |
Participants received quiet time intervention during the active phase of labor. At 4 cm cervical dilation, informed consent was obtained and baseline assessments including Demographic Information Form, Visual Analogue Scale (VAS) for pain, and Visual Analogue Scale for stress were completed. Routine care was provided. At 6 cm and 8 cm cervical dilation, a quiet environment was maintained using Polter headphones for 15 minutes per session. Routine monitoring and standard obstetric care were continued. After interventions, pain and stress were reassessed using VAS. At the second postpartum hour, maternal satisfaction was assessed using the Maternal Satisfaction in Childbirth Scale. |
|
Control Group
At the beginning of the active phase (when cervical dilation was 4 cm), the participant was informed about the study and informed consent was obtained. The Demographic Information Form was completed, and pain was assessed using the Visual Analogue Scale (VAS), while stress was evaluated using a Visual Analogue Scale (VAS). Routine monitoring and standard care were provided. The participant received routine care throughout the active phase. At the end of the phase, pain was assessed using the Visual Analogue Scale (VAS), and stress was evaluated using a Visual Analogue Scale (VAS). Routine care was continued. At the second hour postpartum, the Maternal Satisfaction in Childbirth Scale was completed. |
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Pain level during labor
Tijdsspanne: During labor, between 4-10 cm cervical dilation (latent and active phases)
|
Labor pain levels will be assessed using the Visual Analog Scale (VAS).
Measurements will be performed during the latent and active phases of labor at specific cervical dilation stages (4-10 cm).
|
During labor, between 4-10 cm cervical dilation (latent and active phases)
|
Medewerkers en onderzoekers
Sponsor
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- 2025/55
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Beschrijving IPD-plan
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .