- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT07591909
The Airway Pressures During Bag-Valve-Mask Ventilation
The Airway Pressures During Bag-Valve-Mask Ventilation: A Randomized Crossover Trial
Background and Objective Bag-valve-mask (BVM) ventilation is commonly used in emergency airway management, but the positive pressure generated may increase aspiration risk. This prospective, randomized, simulation-based manikin study aimed to assess how airway pressures change during BVM ventilation using different techniques and neck mobility scenarios.
Methods The study was conducted in a tertiary university hospital between July 15 and August 15, 2024. Emergency medicine residents (PGY-1 to PGY-4) performed ten ventilations using one-hand, two-hand CE, and modified two-hand TE techniques on a manikin under normal and restricted neck mobility. Airway pressures were measured with a real-time pressure sensor. The primary outcome was peak airway pressure; the secondary was the number of ventilations exceeding 20 cmH₂O. All data were automatically recorded, and analyses were performed using SPSS 16.0 with p < 0.05 considered significant.
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Gedetailleerde beschrijving
Introduction:
Emergency department (ED) patients are considered to have an elevated risk of gastric distention and aspiration of gastric contents, making rapid sequence induction (RSI) the preferred intubation procedure. Pre-oxygenation is likely the most critical step in RSI, as it extends the duration of safe apnea time, providing the operator with more time for the intubation process. Although a facemask with a high FiO2 oxygen reservoir is recommended for pre-oxygenation, bag-valve-mask (BVM) ventilation is frequently used in emergency airway management.
Since its development during the polio epidemic in 1953, the BVM has been used for oxygenation and ventilation of critically ill patients. However, the positive pressure generated by the BVM can increase the risk of regurgitation and aspiration of gastric contents into the lungs. Excessive volumes and flow generated with the BVM can not only lead to gastric distention but also increase intrathoracic pressures, potentially causing negative cardiovascular effects.
The aim of this randomized crossover manikin study is to investigate how airway pressures change during ventilation with a BVM using different scenarios and techniques.
Methods:
This is a randomized crossover trial performed in the simulation lab of a tertiary care facility between 15.07.2024 to 15.08.2024. The ethical committee of XXX approved the study and informed consent was obtained from the participants. The participants were emergency medicine residents ranging from postgraduate year 1 (PGY) to PGY4.
In this study, airway pressures during BVM ventilation were continuously recorded using a calibrated pressure sensor placed between the facemask and the bag. All participants were requested to ventilate the Resusci Anne QCPR airway mannequin (Laerdal Medical, Stavanger, Norway) in a randomized manner using one-hand, two-hand (CE method), and modified two-hand (TE method) techniques, while the airway pressures were measured. Two different scenarios were applied to simulate normal and difficult airways while ventilating the airway mannequin. For the difficult airway scenario, a cervical collar was applied to the airway mannequin. To reduce potential bias, the purpose of the study was not explained to the participants Each participant was asked to provide a sufficient amount of air with the BVM to raise the mannequin's chest and to repeat these 10 times in a randomized order. All the pressure values measured during ventilation were recorded as cmH2O. The highest-pressure value measured during ventilations, as well as the number of ventilations during which the pressure exceeded 20 cmH2O, were recorded.
The differences in the pressure values measured using different hand techniques in normal and difficult airway scenarios were evaluated. Additionally, it was assessed which scenario and technique resulted in pressures exceeding 20 cmH2O, based on the theoretical assumption that pressures above this value would open the lower esophageal sphincter and inflate the stomach with air. This assumption was based on previous studies indicating that lower esophageal sphincter pressure is typically exceeded, and gastric inflation begins, when airway pressure surpasses 20 cmH₂O.
Statistical analysis:
The study data were analyzed using the SPSS software version 16.0 for Windows (SPSS Inc., Chicago, IL, USA). Demographic and baseline characteristics were summarized as a mean ± standard deviation for continuous variables and as a percentage of the group for categorical variables. Non-normally distributed data are presented as medians (interquartile range). For each scenario and technique, the participant was considered the unit of analysis. For every participant, the highest pressure value among the 10 ventilations and whether ≥5 of 10 ventilations exceeded 20 cmH2O were used in the analyses The chi-square test was used to compare the ventilations exceeding the 20 cmH2O pressure value with PGY levels. P < 0.05 was accepted as statistically significant.
Studietype
Inschrijving (Werkelijk)
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
-
Antalya, Turkije (Türkiye), 07059
- Akdeniz University Hospital
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Kind
- Volwassen
- Oudere volwassene
Accepteert gezonde vrijwilligers
Beschrijving
Inclusion Criteria:
- 18 years or older.
- Medical residents (Post-graduate years 1-4) or practicing emergency medicine physicians.
- Ability and willingness to provide informed consent to participate in the simulation.
- Experience with basic airway management and BVM ventilation in a clinical setting.
Exclusion Criteria:
- Lack of Experience:
- Any musculoskeletal or neurological condition that would prevent the participant from performing manual BVM maneuvers effectively.
- Refusal to Participate: Inability to provide informed consent.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Onderzoek naar gezondheidsdiensten
- Toewijzing: Gerandomiseerd
- Interventioneel model: Crossover-opdracht
- Masker: Enkel
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Ander: PGY juniors (under 2 yrs)
Residents who have been working as assistants for less than two years
|
Describes the CE hand-holding position during the balloon mask ventilation.
Describes the TE hand-holding position during the balloon mask ventilation.
Describes the One hand-holding position during the balloon mask ventilation.
|
|
Ander: PGY Senior ( above 2 years)
Residents who have been working as assistants for more than two years.
|
Describes the CE hand-holding position during the balloon mask ventilation.
Describes the TE hand-holding position during the balloon mask ventilation.
Describes the One hand-holding position during the balloon mask ventilation.
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Incidence of airway pressure exceeding 20 cmH2O
Tijdsspanne: During the ventilation procedure (a continuous 10-breath sequence per technique/scenario
|
The frequency of breaths delivered with a peak airway pressure greater than 20 cmH2O (the threshold for gastric inflation risk) during Bag-Valve-Mask (BVM) ventilation.
|
During the ventilation procedure (a continuous 10-breath sequence per technique/scenario
|
Medewerkers en onderzoekers
Sponsor
Publicaties en nuttige links
Algemene publicaties
- 1- Weingart SD, Levitan RM. Preoxygenation and prevention of desaturation during emergency airway management. Ann Emerg Med. 2012 Mar;59(3):165-75.e1. doi: 10.1016/j.annemergmed.2011.10.002. 2- Lee CP, Yip YY. Understanding your bag-valve-mask resuscitator. BJA Educ. 2023 Jun;23(6):208-211. doi: 10.1016/j.bjae.2023.03.003. 3- Lawes EG, Campbell I, Mercer D. Inflation pressure, gastric insufflation, and rapid sequence induction. Br J Anaesth. 1987 Mar;59(3):315-8. doi: 10.1093/bja/59.3.315. 4- Bowman FP, Menegazzi JJ, Check BD, Duckett TM. Lower esophageal sphincter pressure during prolonged cardiac arrest and resuscitation. Ann Emerg Med. 1995 Aug;26(2):216-9. doi: 10.1016/s0196-0644(95)70154-0. 5- von Goedecke A, Wagner-Berger HG, Stadlbauer KH, Krismer AC, Jakubaszko J, Bratschke C, Wenzel V, Keller C. Effects of decreasing peak flow rate on stomach inflation during bag-valve-mask ventilation. Resuscitation. 2004 Nov;63(2):131-6. doi: 10.1016/j.resuscitation.2004.04.012.
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Andere studie-ID-nummers
- AkdenizUH
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Beschrijving IPD-plan
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .
Klinische onderzoeken op Noodhulpbeheer
-
Royal Hospital, OmanNog niet aan het wervenMoeilijke luchtweg | Obesitas Moeilijk Airway Airway Management
-
Insel Gruppe AG, University Hospital BernGaslini Children's HospitalAanmelden op uitnodigingAnesthesie | Tracheostomie Complicatie | Emergency Front of Neck Airway bij kinderenZwitserland
-
University of ZurichOnbekendTechnische en niet-technische training van Airway Management op de ICUZwitserland
-
The University of Texas Health Science Center,...VoltooidEndotracheale intubatie | Rapid Airway Management-verstellerVerenigde Staten
-
University Children's Hospital, ZurichVoltooidEmergency Front of Neck Airway bij kinderenZwitserland
-
Harran UniversityVoltooidObesitas Moeilijk Airway Airway ManagementTurkije (Türkiye)
-
Antalya Training and Research HospitalWervingMoeilijke luchtweg | Obesitas (aandoening) | Obesitas & Overgewicht | Moeilijke laryngoscopie | Moeilijke intubatie bij obesitas | Obesitas Moeilijk Airway Airway ManagementTurkije (Türkiye)
-
Hager Montaser Sayed BedeerNog niet aan het wervenBack Rolls Assesment | Back Rolls Management
-
RWTH Aachen UniversityVoltooidAnesthesie met gebruik van LMA (Laryngeal Mask Airway)Duitsland
-
German Institute of Human NutritionNog niet aan het wervenBesluitvorming | Ademhalingstechnieken | Stress management