Macular hole (MH) is a full-thickness defect of the neurosensory retina at the fovea, causing central visual loss. The incidence of idiopathic MH increases with age and is more common in females. Vitreomacular traction is the main pathophysiological factor leading to MH formation.
Pars plana vitrectomy with internal limiting membrane (ILM) peeling has been considered the standard technique for MH repair, achieving high anatomical closure rates. However, for large and refractory holes, conventional ILM peeling may not be sufficient.
The inverted ILM flap technique was developed as an alternative for large MHs (≥400 µm). This method allows the peeled ILM to be inverted and placed over the hole to serve as a scaffold for glial proliferation, enhancing closure rates and improving visual outcomes.
More recently, Tenon capsule graft has been introduced as an autologous biological scaffold for macular hole closure. Tenon tissue is rich in fibroblasts and extracellular matrix, which may promote retinal repair and facilitate closure in cases resistant to conventional approaches.
Optical coherence tomography (OCT) has become essential for evaluating macular hole dimensions, classifying stages, and confirming closure after surgery. It provides high-resolution images that allow detailed morphologic analysis.
Optical coherence tomography angiography (OCTA) enables noninvasive assessment of retinal and choroidal vasculature. Postoperative OCTA studies have shown changes in foveal avascular zone (FAZ) and vessel density in both superficial and deep plexuses, which may correlate with visual recovery.
Comparative studies between Tenon capsule graft and ILM flap using OCT and OCTA are limited, and further research is required to assess their relative efficacy in terms of anatomical closure, visual improvement, and vascular restoration. This study aims to address that gap.
The aim of this study is to compare the functional visual outcomes, anatomical closure rate and macular perfusion changes assessed by OCT and OCTA after surgical repair of macular hole using Tenon capsule graft versus ILM flap.
The study will be conducted in the ophthalmology department, at Ain Shams University Hospitals, Cairo, Egypt.
Inclusion criteria:
- Patients diagnosed with idiopathic full-thickness macular hole
- ≥400 µm in horizontal diameter
Exclusion criteria:
- Media opacity preventing adequate OCT/OCTA imaging
- Other retinal vascular pathology as retinal vascular occlusion
- Intraoperative complications
- Signal noise ratio using OCTA <6\10
- Poor fixation of the patient
Group 1: Surgical repair of MH using Tenon capsule graft. Group 2: Surgical repair of MH using ILM Flap.
Sample Size:
Due to the novelty of the procedure and the rarity of cases needing surgical treatment and the expensive cost of intervention. This study is also a pilot study. This study is exempted from sample size calculation.
Study type: Prospective interventional .(Pilot study) Ethical Considerations: Written informed consent will be obtained from patients, after approval of the research ethics committee of the Faculty of Medicine, Ain Shams University, Cairo, Egypt.
Study Tools
Preoperative examination :
All participants will have complete ocular examination including:
- Best corrected visual acuity (BCVA) with Snellen E and then transformation to Log MAR
- Slit-lamp examination
- Fundus examination using 90 D lens
- Intraocular pressure measurement by Goldmann applanation tonometry
- Preoperative OCT to assess MH base diameter and narrowest diameter and thickness of edges to calculate MH indices
- OCTA (OptovueInc, Fremont, CA). Sequential optical coherence tomography scans of a specific retinal region will be performed (central 3x3 Macular area Superficial, deep capillary plexus and choriocapillaris) and images will be processed in order to obtain motion contrast of erythrocytes within the vessel, thereby providing detailed imaging of the retinal capillary network. Capillary plexus density (CPD) of vessels in SCP, DCP and the size of the FAZ will be detected by OCTA en-face images.
Operative technique:
In all patients (Group A & B), PPV will be performed using a 23-gauge, transconjunctival, microincision vitrectomy system. Diluted triamcinolone acetonide (40 mg/ml) will be used to visualize the vitreous. After core vitrectomy, posterior hyaloid detachment will be attempted with the vitrectomy cutter in the suction mode. Then, the ILM will be stained using 0.05% Brilliant Blue G (OCUBLUE PLUS, India).
In Group A: tenon capsule graft will be attempted.
In Group B: free flap ILM peeling will be attempted
SF6 gas will be used as tamponade in both groups
More than one vitreoretinal surgeon will participate
Postoperative assessment:
Patients will be examined one day and three months after surgery. Postoperative assessment will include the following with each assessment: Full ophthalmic examination (UCVA, BCVA, anterior segment assessment, Goldman applanation tonometry measurement (in all follow up visits except 1st day postoperative), fundus examination).
Postoperative OCT to assess Anatomical closure and type of closure Post-operative macular scans by OCTA (OptovueInc, Fremont, CA). Sequential optical coherence tomography scans of a specific retinal region will be performed (central 3x3 Macular area Superficial, deep capillary plexus and choriocapillaris) and images will be processed in order to obtain motion contrast of erythrocytes within the vessel, thereby providing detailed imaging of the retinal capillary network. Capillary plexus density (CPD) of vessels in SCP, DCP and the size of the FAZ will be detected by OCTA en-face images
Primary outcome:
- Improvement in BCVA
Secondary outcome:
- OCT parameters of healing and type of healing
- OCTA parameters of macular vessel density
Statistical Analysis and Statistical Package Data will be collected and analyzed with proper statistical tests.
Studietype
Inschrijving (Geschat)
Fase
- Niet toepasbaar
Contacten en locaties
Studiecontact
- Naam: Khaled Nehad Elsherief
- Telefoonnummer: 0201225602369
- E-mail: khalednehad0100209@med.asu.edu.eg
Studie Contact Back-up
- Naam: Mohammad Ahmed Rashad
- Telefoonnummer: +20 111 575 8888
Studie Locaties
-
-
Abbassia
-
Cairo, Abbassia, Egypte
- Werving
- Ain Shams University
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Kind
- Volwassen
- Oudere volwassene
Accepteert gezonde vrijwilligers
Beschrijving
Inclusion Criteria:
- Patients diagnosed with idiopathic full-thickness macular hole
- ≥400 µm in horizontal diameter
Exclusion Criteria:
- Media opacity preventing adequate OCT/OCTA imaging
- Other retinal vascular pathology as retinal vascular occlusion
- Intraoperative complications
- Signal noise ratio using OCTA <6\10
- Poor fixation of the patient
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Behandeling
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Ander: ILM flap
ILM flap for treatment of macular hole as control
|
Prospective interventional study In all patients (Group A & B), PPV will be performed using a 23-gauge, transconjunctival, microincision vitrectomy system. Diluted triamcinolone acetonide (40 mg/ml) will be used to visualize the vitreous. After core vitrectomy, posterior hyaloid detachment will be attempted with the vitrectomy cutter in the suction mode. Then, the ILM will be stained using 0.05% Brilliant Blue G (OCUBLUE PLUS, India). In Group A: tenon capsule graft will be attempted In Group B: free flap ILM peeling will be attempted SF6 gas will be used as tamponade in both groups More than one vitreoretinal surgeon will participate
Andere namen:
|
|
Actieve vergelijker: Tenon capsule graft
Tenon capsule graft for treatment of macular hole
|
Prospective interventional study In all patients (Group A & B), PPV will be performed using a 23-gauge, transconjunctival, microincision vitrectomy system. Diluted triamcinolone acetonide (40 mg/ml) will be used to visualize the vitreous. After core vitrectomy, posterior hyaloid detachment will be attempted with the vitrectomy cutter in the suction mode. Then, the ILM will be stained using 0.05% Brilliant Blue G (OCUBLUE PLUS, India). In Group A: tenon capsule graft will be attempted In Group B: free flap ILM peeling will be attempted SF6 gas will be used as tamponade in both groups More than one vitreoretinal surgeon will participate
Andere namen:
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
-Improvement in best corrected visual acuity (BCVA)
Tijdsspanne: 3 months postoperative
|
Improvement in BCVA measured by snellen E chart then transformation to Logarithm of the minimum angle of resolution (Log MAR)
|
3 months postoperative
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
OCT
Tijdsspanne: 3 months postoperative
|
To assess healing and closure of hole by OCT OptovueInc, Fremont, CA (qualitative measure to assess if the hole is closed or not)
|
3 months postoperative
|
|
OCTA
Tijdsspanne: 3 months
|
superficial and deep capillary plexuses vessel density assessment by OCTA OptovueInc, Fremont, CA Sequential optical coherence tomography scans of a specific retinal region will be performed (central 3x3 Macular area Superficial, deep capillary plexus and choriocapillaris) and images will be processed in order to obtain motion contrast of erythrocytes within the vessel, thereby providing detailed imaging of the retinal capillary network. Capillary plexus density (CPD) of vessels in SCP, DCP and the size of the FAZ will be detected by OCTA en-face images. (Density is measured as percentage and thickness is measured by micrometer ) |
3 months
|
Medewerkers en onderzoekers
Sponsor
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Geschat)
Studie voltooiing (Geschat)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- FMASU MD351/2025
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .