Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

Serial Diaphragm Ultrasound Evaluation During Inspiratory Muscle Training in Prolonged Mechanical Ventilation

16 juli 2026 bijgewerkt door: MENG-JER HSIEH, Chang Gung Memorial Hospital

Diaphragm Ultrasound Evaluation of the Effects of High Intensity or Low Intensity Inspiratory Muscle Training in Patients With Prolonged Mechanical Ventilation

Diaphragm dysfunction contributes to prolonged mechanical ventilation (PMV) and difficult weaning. Inspiratory muscle training (IMT) may improve respiratory muscle performance, while serial diaphragm ultrasound offers a bedside method for monitoring diaphragmatic recovery. This study used diaphragm ultrasound to evaluate the effects of high- versus low-intensity IMT in patients with PMV and diaphragm dysfunction.

In this prospective study, patients received high- or low-intensity IMT for up to 2 weeks or until ventilator liberation. Respiratory mechanics, including respiratory rate, tidal volume, minute ventilation, rapid shallow breathing index, and maximal inspiratory pressure, were assessed twice weekly. Diaphragm excursion and thickening fraction were also measured serially after IMT initiation. Changes in respiratory physiological parameters and diaphragm ultrasound measurements were compared between the two IMT groups, and differences in ventilator liberation outcomes were evaluated.

Studie Overzicht

Gedetailleerde beschrijving

Prolonged mechanical ventilation (PMV) is associated with substantial morbidity, mortality, and healthcare resource utilization. In Taiwan, approximately 170,000 patients receive mechanical ventilation annually, of whom an estimated 13%-16% remain ventilator-dependent for more than 21 days and 3.7%-5.6% require ventilatory support for more than 63 days. Diaphragm dysfunction is an important physiological contributor to difficult ventilator liberation. Prolonged mechanical unloading, systemic inflammation, critical illness, and disuse may result in diaphragmatic atrophy, structural injury, and impaired contractility.

Inspiratory muscle training (IMT) is used during ventilator rehabilitation to improve inspiratory muscle strength and endurance. IMT may be delivered using resistive-loading or threshold-loading devices. Threshold-loading devices provide a relatively constant, flow-independent inspiratory resistance and permit training intensity to be prescribed according to maximal inspiratory pressure (Pimax). Similar to peripheral skeletal muscle training, respiratory muscle adaptation is influenced by the magnitude and progression of the applied workload. However, the appropriate training intensity for patients with PMV and diaphragm dysfunction remains uncertain. Higher-intensity training may provide a stronger physiological stimulus but may be less well tolerated, whereas lower-intensity training may be easier to perform but may produce a smaller training response.

The effects of IMT have traditionally been evaluated using global respiratory measurements such as Pimax, tidal volume, respiratory rate, minute ventilation, and the rapid shallow breathing index. Although these measurements provide clinically relevant information, most are effort-dependent and do not directly assess diaphragm-specific mechanical recovery. Point-of-care diaphragm ultrasound provides a noninvasive bedside method for serial evaluation of diaphragmatic function. Diaphragm excursion reflects craniocaudal diaphragmatic displacement during inspiration, while diaphragm thickening fraction reflects inspiratory muscle contraction within the zone of apposition.

This prospective, single-center, randomized controlled trial compared high-intensity and low-intensity inspiratory muscle training (IMT) in adults with prolonged mechanical ventilation and inspiratory muscle weakness who had been transferred from an intensive care unit to a specialized respiratory care center. Eligible participants were randomly assigned to receive an individualized IMT workload based on baseline maximal inspiratory pressure (Pimax). The high-intensity group trained at 50% of baseline Pimax, and the low-intensity group trained at 20% of baseline Pimax.

IMT was administered using a Dofin® adjustable-resistance threshold inspiratory muscle trainer (GaleMed Corporation, Taiwan). During each training session, the device was connected directly to the endotracheal or tracheostomy tube by a respiratory therapist after temporary disconnection from the mechanical ventilator. Each cycle included 6-10 inspiratory efforts, and five cycles were performed daily. Rest periods of 1-3 minutes were provided between cycles to reduce acute respiratory muscle fatigue. Pimax was reassessed twice weekly, and the training resistance was adjusted according to the updated measurement.

Participants were continuously observed during IMT for signs of respiratory distress or hemodynamic instability. Training was discontinued and mechanical ventilation was resumed when clinically significant oxygen desaturation, tachycardia, arrhythmia, diaphoresis, pallor, cyanosis, altered mental status, severe dyspnea, or other evidence of intolerance occurred. When a participant could not tolerate the prescribed high-intensity workload, resistance was reduced in 10% increments. A session was terminated when intolerance persisted after a reduction of more than 20% from the prescribed workload. Training continued for up to 2 weeks or until successful liberation from mechanical ventilation.

Baseline demographic and clinical characteristics were prospectively recorded. Respiratory mechanics, including respiratory rate, tidal volume, minute ventilation, rapid shallow breathing index, and Pimax, were assessed twice weekly during the intervention period. Mechanical ventilation duration and ventilator days after IMT initiation were also recorded.

Point-of-care diaphragm ultrasound was performed at baseline and on days 4, 7, and 10 after IMT initiation. During ultrasound assessment, ventilatory support was changed to continuous positive airway pressure mode to standardize the measurement condition. Right diaphragmatic excursion was measured using M-mode ultrasonography with a convex-array transducer positioned near the intersection of the right costal margin and midclavicular line. Diaphragm thickness was measured using a high-frequency linear-array transducer placed over the right zone of apposition near the anterior axillary line. Thickening fraction was calculated from the difference between inspiratory and expiratory diaphragm thickness relative to expiratory thickness.

Serial changes in respiratory mechanics and diaphragm ultrasound measurements were compared between the high-intensity and low-intensity inspiratory muscle training groups using statistical methods appropriate for repeated measurements. Ventilator liberation was evaluated using time-to-event methods. Kaplan-Meier analysis was used to compare the cumulative probability of successful ventilator liberation, with participants who did not achieve liberation censored at 28 days. Group differences were assessed using the log-rank test, and Cox proportional hazards regression was used to evaluate the association between inspiratory muscle training intensity and time to successful ventilator liberation.

The study was approved by the Institutional Review Board of Chang Gung Medical Foundation, Taiwan. Written informed consent was obtained from each participant's legally authorized representative before enrollment. Study procedures were conducted in accordance with the Declaration of Helsinki.

Studietype

Ingrijpend

Inschrijving (Werkelijk)

36

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

      • Taoyuan, Taiwan
        • Linkou Gung Memorial Hospital

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Volwassen
  • Oudere volwassene

Accepteert gezonde vrijwilligers

Nee

Beschrijving

Inclusion Criteria:

  1. Willing and able to provide written informed consent.
  2. Adults aged >20 years.
  3. Patients requiring mechanical ventilation for >21 days and admitted to the Respiratory Care Center (RCC).
  4. Hemodynamically stable and not receiving vasopressor therapy.
  5. Clinically stable and considered by the attending physician to be ready to begin weaning from mechanical ventilation. Ventilator settings must meet all of the following criteria:

(1) Fraction of inspired oxygen (FiO₂) < 0.60. (2) Positive end-expiratory pressure (PEEP) ≤10 cmH₂O. (3) Able to trigger spontaneous breaths on the ventilator. (4) Respiratory rate <25 breaths/min. (5) Respiratory muscle weakness confirmed by maximal inspiratory pressure (MIP), defined as MIP <30 cmH₂O.

Exclusion Criteria:

  1. Hemodynamic instability, including cardiac arrhythmia, decompensated heart failure, or acute coronary syndrome.
  2. Active hemoptysis.
  3. Presence of a chest tube.
  4. Use of home mechanical ventilation.
  5. Uncontrolled pain or dyspnea.
  6. Patients determined to be ventilator-dependent and requiring long-term mechanical ventilation.
  7. Patients or their legally authorized representatives who are unwilling or unable to provide written informed consent.

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Behandeling
  • Toewijzing: Gerandomiseerd
  • Interventioneel model: Parallelle opdracht
  • Masker: Enkel

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Experimenteel: high intensity IMT
high IMT training intensity
high intensity IMT: high intensity training
Actieve vergelijker: low intensity IMT
low IMT training intensity
low intensity IMT: low intensity training

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Tijdsspanne
Changes in diaphragm excursion measured by diaphragm ultrasound
Tijdsspanne: From enrollment to the end of study at 2 weeks.
From enrollment to the end of study at 2 weeks.
Changes in thickening fraction measured by diaphragm ultrasound
Tijdsspanne: From enrollment to the end of study at 2 weeks.
From enrollment to the end of study at 2 weeks.

Secundaire uitkomstmaten

Uitkomstmaat
Tijdsspanne
Successful ventilator liberation
Tijdsspanne: From enrollment to the end of study at 2 weeks.
From enrollment to the end of study at 2 weeks.
Change in maximal inspiratory pressure (PImax)
Tijdsspanne: From enrollment to the end of study at 2 weeks.
From enrollment to the end of study at 2 weeks.
Change in respiratory rate (RR)
Tijdsspanne: From enrollment to the end of study at 2 weeks.
From enrollment to the end of study at 2 weeks.
Change in tidal volume (VT)
Tijdsspanne: From enrollment to the end of study at 2 weeks.
From enrollment to the end of study at 2 weeks.
Change in minute ventilation (MV)
Tijdsspanne: From enrollment to the end of study at 2 weeks.
From enrollment to the end of study at 2 weeks.
Change in rapid shallow breathing index (RSBI)
Tijdsspanne: From enrollment to the end of study at 2 weeks.
From enrollment to the end of study at 2 weeks.

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

9 maart 2023

Primaire voltooiing (Werkelijk)

27 mei 2025

Studie voltooiing (Werkelijk)

30 juni 2025

Studieregistratiedata

Eerst ingediend

7 juli 2026

Eerst ingediend dat voldeed aan de QC-criteria

16 juli 2026

Eerst geplaatst (Werkelijk)

17 juli 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

17 juli 2026

Laatste update ingediend die voldeed aan QC-criteria

16 juli 2026

Laatst geverifieerd

1 juli 2026

Meer informatie

Termen gerelateerd aan deze studie

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren