- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT07730398
Optimizing Noisy Galvanic Vestibular Stimulation Frequency Range for Enhancing Vestibular Perception and Manual Control Performance
22 juli 2026 bijgewerkt door: National Aeronautics and Space Administration (NASA)
Assessments of Performance in Healthy Control Subjects
This randomized crossover interventional study evaluated the effects of different frequency ranges of noisy galvanic vestibular stimulation (nGVS) on vestibular perception, perceptual motion tracking, and manual control performance in healthy adults.
Each participant completed three experimental conditions in randomized order: no stimulation (control), low-frequency nGVS, and high-frequency nGVS.
Vestibular perceptual thresholds, perceptual tracking, and manual control performance were assessed during each condition to determine whether stimulation frequency influenced sensorimotor function.
Studie Overzicht
Toestand
Voltooid
Gedetailleerde beschrijving
The purpose of this study was to investigate whether the frequency content of noisy galvanic vestibular stimulation influences vestibular perceptual sensitivity, tracking accuracy, and manual control performance.
Healthy adult participants completed a randomized crossover protocol in which they received no stimulation, low-frequency nGVS, and high-frequency nGVS during separate experimental conditions within a single study session.
Outcome measures included vestibular perceptual thresholds, tracking error rate, and measures of manual control performance.
The results were intended to improve understanding of vestibular neuromodulation and inform optimization of nGVS parameters for future aerospace and clinical applications.
Studietype
Ingrijpend
Inschrijving (Werkelijk)
18
Fase
- Niet toepasbaar
Contacten en locaties
In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.
Studie Locaties
-
-
Texas
-
Houston, Texas, Verenigde Staten, 77058
- Nasa Jsc B21
-
-
Deelname Criteria
Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Volwassen
- Oudere volwassene
Accepteert gezonde vrijwilligers
Ja
Beschrijving
Inclusion Criteria:
- Subjects were required to pass a physical exam adminisitrated by NASA JSC Clinic.
Exclusion Criteria:
- No history of neurologic, vestibular, or autonomic disease.
Studie plan
Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Fundamentele wetenschap
- Toewijzing: Gerandomiseerd
- Interventioneel model: Crossover-opdracht
- Masker: Enkel
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Geen tussenkomst: Control - No noisy galvanic vestibular stimulation
Participants completed testing without noisy galvanic vestibular stimulation.
|
|
|
Experimenteel: Low-frequency noisy galvanic vestibular stimulation
Participants received low-frequency noisy galvanic vestibular stimulation during testing.
Low frequency was 0-2 Hz.
|
Participants received low-frequency noisy galvanic vestibular stimulation through electrodes placed over the bilateral mastoid processes during experimental testing.
Stimulation parameters were consistent with the approved study protocol.
Frequency was 0-2Hz white noise, 300uA amplitude.
|
|
Experimenteel: High-frequency noisy galvanic vestibular stimulation
Participants received high-frequency noisy galvanic vestibular stimulation during testing.
High-frequency was 10-30 Hz.
|
Participants received high-frequency noisy galvanic vestibular stimulation through electrodes placed over the bilateral mastoid processes during experimental testing.
Stimulation parameters were consistent with the approved study protocol.
Frequency was 10-30Hz white noise, 300uA amplitude.
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Vestibular Direction Recognition Threshold
Tijdsspanne: Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
Vestibular perceptual sensitivity was assessed using roll-tilt and interaural translation direction recognition tasks performed on a six-degree-of-freedom motion platform.
Direction recognition thresholds were estimated from participant responses using an adaptive three-down, one-up staircase procedure and cumulative Gaussian psychometric curve fitting.
Lower threshold values indicate greater vestibular sensitivity and improved perception of self-motion.
|
Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
|
Perceptual Motion Tracking Accuracy
Tijdsspanne: Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
Perceptual motion tracking performance was evaluated during continuous pseudorandom roll motion.
Participants used a joystick to continuously indicate their perceived direction and magnitude of platform motion.
Performance was quantified using the root mean square error (RMSE) between joystick responses and the programmed motion stimulus, with lower RMSE values indicating more accurate perception and tracking of self-motion.
|
Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
|
Manual Control Nulling Accuracy
Tijdsspanne: Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
Manual control performance was evaluated during continuous pseudorandom roll motion while participants used a joystick to actively minimize platform motion by generating corrective control inputs.
Performance was quantified using the root mean square error (RMSE) between the platform tilt angle and the upright position over time.
Lower RMSE values indicate more effective manual control and disturbance rejection.
|
Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Roll-Tilt Vestibular Direction Recognition Threshold
Tijdsspanne: Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
Vestibular perceptual threshold for roll-tilt motion was measured using a computerized three-down, one-up adaptive staircase procedure during a 1 Hz sinusoidal motion stimulus.
Thresholds were estimated by fitting a cumulative Gaussian psychometric function to participants' left/right direction recognition responses.
Lower threshold values indicate greater vestibular sensitivity.
|
Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
|
Interaural Translation Vestibular Direction Recognition Threshold
Tijdsspanne: Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
Vestibular perceptual threshold for interaural translation motion was measured using a computerized three-down, one-up adaptive staircase procedure during a 1 Hz sinusoidal motion stimulus.
Thresholds were estimated by fitting a cumulative Gaussian psychometric function to participants' left/right direction recognition responses.
Lower threshold values indicate greater vestibular sensitivity.
|
Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
|
Vestibular Direction Recognition Bias
Tijdsspanne: Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
Response bias during the vestibular direction recognition task was estimated from the mean of the cumulative Gaussian psychometric function.
Bias represents the stimulus magnitude at which participants were equally likely to perceive motion in either direction, providing a measure of systematic perceptual offset.
|
Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
|
Perceptual Motion Tracking Variability
Tijdsspanne: Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
Variability of perceptual motion tracking performance during continuous pseudorandom roll motion.
Tracking variability was quantified using statistical measures including standard deviation and variance of tracking performance, providing an assessment of the consistency and precision of participant responses.
|
Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
|
Manual Control Nulling Variability
Tijdsspanne: Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
Variability of manual control performance during the nulling task was quantified using standard deviation, variance, and mean absolute deviation of chair tilt relative to the upright position.
These measures assessed the consistency and precision of participants' ability to minimize platform motion.
|
Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
Medewerkers en onderzoekers
Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.
Onderzoekers
- Hoofdonderzoeker: Scott J Wood, PhD, National Aeronautics and Space Administration (NASA)
Studie record data
Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.
Bestudeer belangrijke data
Studie start (Werkelijk)
19 februari 2024
Primaire voltooiing (Werkelijk)
18 maart 2024
Studie voltooiing (Werkelijk)
18 maart 2024
Studieregistratiedata
Eerst ingediend
15 juli 2026
Eerst ingediend dat voldeed aan de QC-criteria
22 juli 2026
Eerst geplaatst (Werkelijk)
28 juli 2026
Updates van studierecords
Laatste update geplaatst (Werkelijk)
28 juli 2026
Laatste update ingediend die voldeed aan QC-criteria
22 juli 2026
Laatst geverifieerd
1 juli 2026
Meer informatie
Termen gerelateerd aan deze studie
Andere studie-ID-nummers
- eIRB Study 0530
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
JA
Beschrijving IPD-plan
De-identified individual participant data underlying the results reported in the publication, including vestibular threshold measurements, perceptual motion tracking data, manual control performance data, and associated analysis code, will be made available upon reasonable request to the corresponding author.
Additional study documents, including the study protocol, statistical analysis plan, and data dictionary, will also be available to support reproducibility.
Data sharing will be subject to applicable institutional policies, IRB requirements, and any NASA data-sharing requirements in effect at the time of the request.
IPD-tijdsbestek voor delen
For at least five years following publication.
IPD-toegangscriteria voor delen
Data can be requested through the NASA Life Sciences Portal (https://www.nasa.gov/hrp/nlsp/).
IPD delen Ondersteunend informatietype
- LEERPROTOCOOL
- SAP
- ANALYTIC_CODE
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Nee
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Nee
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .