Use of Ultrasound Imaging in Confirming Osteopathic Spinal Diagnosis
Investigating Use of Musculoskeletal Ultrasound in Conjunction With Manual Somatic Dysfunction Diagnosis
In the field of Osteopathic Medicine, diagnosis of potential areas of dysfunction are diagnosed by the physician using their hands and expertise in noticing subtle differences in symmetry, tone, swelling etc.. In this study, we propose the use of ultrasound, which is a non invasive imaging technique that requires no radiation exposure, to confirm the diagnosis made with the physician's hands. We believe this will add a layer of objectivity to this diagnosis, in that you have numbers that have been measured to back up the diagnosis made based on feel. In this study, we can confirm whether or not these differences felt are true from an objective standpoint. We will compare patients with dysfunction palpated on manual exam to those with no palpated dysfunction in terms of their median asymmetry when measured using musculoskeletal ultrasound.
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Studietype
Inschrijving (Werkelijk)
Contacten en locaties
Studie Locaties
-
-
New York
-
Brooklyn, New York, Verenigde Staten, 11210
- Leonid Tafler DO Osteopathic Medical Treatment
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Bemonsteringsmethode
Studie Bevolking
Patients of Dr. Leonid Tafler's private practice
Beschrijving
Inclusion Criteria:
- patients found to have somatic dysfunction on palpation of the spine
Exclusion Criteria:
- patients that decline participation, otherwise no exclusion criteria
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Observatiemodellen: CASE_CONTROL
- Tijdsperspectieven: CROSS_SECTIONAL
Cohorten en interventies
Groep / Cohort |
Interventie / Behandeling |
|---|---|
|
Palpated somated dysfuncion
Patients in this group would be those who were palpated by the Osteopathic Physician and found to have an identifiable somatic dysfunction of the spine on manual exam. These patients then immediately undergo spinal ultrasound to confirm whether or not there is measured asymmetry in the spine. |
Patient will undergo transverse spinal ultrasound of the spinal segment of interest, and the image taken will be measured for the distance from the facet joint on each side to the skin. The absolute value of the difference between these measurements is then recorded as the measured asymmetry. |
|
No Palpated Somatic Dysfunction
Patients with no somatic dysfunction palpated by the osteopathic physician on initial manual examination. |
Patient will undergo transverse spinal ultrasound of the spinal segment of interest, and the image taken will be measured for the distance from the facet joint on each side to the skin. The absolute value of the difference between these measurements is then recorded as the measured asymmetry. |
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Measured Asymmetry
Tijdsspanne: Single measurement
|
This is the absolute value of the difference between the measured distance from the left facet joint to the skin, and the right facet joint to the skin. This measurement is obtained from a transverse ultrasound image using the caliper function on the ultrasound machine. |
Single measurement
|
Medewerkers en onderzoekers
Onderzoekers
- Hoofdonderzoeker: Mikhail Volokitin, DO, Touro College of Osteopathic Medicine - Harlem, NY Campus
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- 28463
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .