- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT07858136
The Effect of Catheter Size on the Efficacy of Ultralow-flow Extracorporeal Carbon Dioxide Removal System in Acute Respiratory Distress Syndrome (Cath-COR)
The Effect of Catheter Size on the Efficacy of Ultralow-flow Extracorporeal Carbon Dioxide Removal System in Acute Respiratory Distress Syndrome: a Pilot Randomized Controlled Trial
This pilot randomized controlled trial will evaluate whether catheter size affects the efficacy and performance of ultra-low-flow extracorporeal carbon dioxide removal (ECCO₂R) in mechanically ventilated adults with acute respiratory distress syndrome (ARDS) and hypercapnic respiratory acidosis. Participants will be randomly assigned to receive ECCO₂R using a 12F, 13F, or 15F catheter. The primary outcome is the percentage change in PaCO₂ from baseline during ECCO₂R. Secondary outcomes include achievement and time to correction of hypercapnic respiratory acidosis, changes in PaO₂, circuit lifespan, maximum blood flow, and device- and patient-related complications.
Studie Overzicht
Toestand
Interventie / Behandeling
Gedetailleerde beschrijving
Acute respiratory distress syndrome (ARDS) may require lung-protective mechanical ventilation to reduce ventilator-induced lung injury. However, limiting tidal volume, driving pressure, plateau pressure, respiratory rate, and mechanical power may result in hypercapnia and respiratory acidosis in some patients.
Ultra-low-flow extracorporeal carbon dioxide removal (ECCO₂R) may facilitate carbon dioxide removal while allowing maintenance of a lung-protective or ultra-protective ventilatory strategy. Compared with conventional high-flow extracorporeal carbon dioxide removal, ultra-low-flow ECCO₂R can be performed using smaller vascular catheters.
The efficacy of ultra-low-flow ECCO₂R may be influenced by catheter size because catheter diameter affects vascular resistance and achievable blood flow through the extracorporeal circuit. However, the optimal catheter size for achieving effective carbon dioxide removal while minimizing catheter-related risks remains uncertain.
This study is a prospective, randomized, three-arm pilot study. Adult patients with ARDS and hypercapnic respiratory acidosis who meet predefined criteria despite lung-protective mechanical ventilation will be randomly assigned to receive ultra-low-flow ECCO₂R using a 12F, 13F, or 15F catheter.
Participants will undergo ECCO₂R for a minimum of 72 hours or until predefined criteria for discontinuation are met. Blood flow will initially be set within the protocol-defined range and increased incrementally according to PaCO₂ response and hemodynamic safety parameters.
The study will evaluate the effect of catheter size on carbon dioxide removal, correction of hypercapnic respiratory acidosis, oxygenation, circuit lifespan, maximum blood flow, and patient- and device-related complications.
Studietype
Inschrijving (Geschat)
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
Bangkok
-
Bangkok, Bangkok, Thailand, 10330
- Chulalongkorn university
-
Contact:
- Nattachai Srisawat, Prof. Dr.
- Telefoonnummer: 02 256 4000 Ext. 3597, 3678
- E-mail: drnattachai@yahoo.com
-
Contact:
- Phruet Soipetkasem, MD
- Telefoonnummer: 0612708090
- E-mail: phruetsoi@gmail.com
-
Hoofdonderzoeker:
- Nattachai Srisawat, MD, PhD, Professor
-
Onderonderzoeker:
- Phruet Soipetkasem, MD
-
Onderonderzoeker:
- Nattha Lumlertgul, MD, PhD
-
Onderonderzoeker:
- Sadudee Peerapornratana, MD
-
Onderonderzoeker:
- Pongthep Theerawit, MD, Assoc. Prof.
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
Participants must meet all of the following criteria:
-
Age ≥18 years.
-
Acute respiratory distress syndrome (ARDS), mild to moderate severity, with a PaO₂/FiO₂ ratio of 100-300 while receiving PEEP ≥5 cmH₂O, after initiation of mechanical ventilation within the preceding 72 hours.
-
Hypercapnic respiratory acidosis, defined by PaCO₂ >60 mmHg and/or arterial blood gas pH <7.25 due to respiratory acidosis despite mechanical ventilation exceeding the protocol-defined lung-protective strategy, characterized by one or more of the following:
- Driving pressure >15 cmH₂O;
- Plateau pressure >27 cmH₂O;
- Tidal volume >6 mL/kg predicted body weight; or
- Mechanical power >17 J/min associated with respiratory rate >25 breaths/min.
Exclusion Criteria:
- Severe shock that is preload non-responsive and requires norepinephrine >1 µg/kg/min.
- Acute brain injury or cerebral edema, increased intracranial pressure, status epilepticus, intracerebral hemorrhage, or acute ischemic stroke.
- Pregnancy.
- Morbid obesity with BMI >40 kg/m².
- Chronic respiratory acidosis.
- End-stage cancer patients.
- Coagulation disorders, defined as a platelet count of less than 10,000 cells/mm3 or an INR greater than 3.
- Patients undergoing targeted temperature management for 24 hours after return of spontaneous circulation.
- End-stage renal disease (ESRD) patients with a blood urea nitrogen (BUN) level greater than 60 mg/dL.
- Patients or legal representatives who do not consent to participation.
- Patients with an indication for ECMO according to the EOLIA trial criteria, specifically a PF ratio < 50 mmHg more than 3 hours or a PF ratio < 80 mmHg more than 6 hours.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Behandeling
- Toewijzing: NVT
- Interventioneel model: Opdracht voor een enkele groep
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: Ultralow-flow extracorporeal carbon dioxide removal system
|
Participants randomized to receive ultra-low-flow extracorporeal carbon dioxide removal (ECCO₂R) using a 12 French (12F) catheter Participants randomized to receive ultra-low-flow extracorporeal carbon dioxide removal (ECCO₂R) using a 13 French (13F) catheter Participants randomized to receive ultra-low-flow extracorporeal carbon dioxide removal (ECCO₂R) using a 15 French (15F) catheter |
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Percentage Change in PaCO₂ From Baseline
Tijdsspanne: Baseline and 1, 6, 12, 24, 48, and 72 hours after initiation of ECCO₂R.
|
Percentage change in arterial partial pressure of carbon dioxide (PaCO₂) from baseline after initiation of ultra-low-flow ECCO₂R. Unit of Measure: Percent (%) |
Baseline and 1, 6, 12, 24, 48, and 72 hours after initiation of ECCO₂R.
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Percentage of Participants Achieving Correction of Hypercapnic Respiratory Acidosis
Tijdsspanne: 1, 6, 12, 24, 48, and 72 hours after using a lung protective strategy under ECCO2R
|
Percentage of achievement (% of achievement) in resolving hypercapnic respiratory acidosis (PaCO2 < 50 mmHg and pH>7.30) from hour 0 in acute respiratory distress syndrome (ARDS) patients ventilated using a lung protective strategy with ECCO2R, evaluated for each catheter size at 1, 6, 12, 24, 48, and 72 hours. |
1, 6, 12, 24, 48, and 72 hours after using a lung protective strategy under ECCO2R
|
|
Time to achievement (hours) in resolving hypercapnic respiratory acidosis
Tijdsspanne: From using a lung protective strategy under ECCO₂R through 72 hours.
|
Time to achievement (hours) in resolving hypercapnic respiratory acidosis from hour 0 in acute respiratory distress syndrome (ARDS) patients ventilated using a lung protective strategy with ECCO2R, evaluated for each catheter size. |
From using a lung protective strategy under ECCO₂R through 72 hours.
|
|
Change in PaO₂/FiO2 ratio From Baseline
Tijdsspanne: 1, 6, 12, 24, 48, and 72 hours.
|
Change in PaO₂/FiO2 ratio from baseline following initiation of ECCO₂R. |
1, 6, 12, 24, 48, and 72 hours.
|
|
Circuit Lifespan
Tijdsspanne: From initiation of ECCO₂R through 72 hours.
|
Duration of use of the ECCO₂R circuit from initiation until circuit replacement or discontinuation. |
From initiation of ECCO₂R through 72 hours.
|
|
Maximum Blood Flow Achieved During ECCO₂R
Tijdsspanne: During the ECCO₂R treatment period, up to 72 hours.
|
Maximum blood flow rate achieved during ECCO₂R while maintaining MAP >65 mmHg and protocol-defined circuit pressure safety criteria. |
During the ECCO₂R treatment period, up to 72 hours.
|
|
ECCO₂R-Related Complications
Tijdsspanne: From initiation of ECCO₂R through 72 hours.
|
Occurrence of complications including catheter-related bleeding, anemia requring blood transfusion, hemolysis, catheter infection, circuit thrombosis, hemodynamic instability, and other patient- or device-related complications. |
From initiation of ECCO₂R through 72 hours.
|
Medewerkers en onderzoekers
Sponsor
Studie record data
Bestudeer belangrijke data
Studie start (Geschat)
Primaire voltooiing (Geschat)
Studie voltooiing (Geschat)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- IRB. No. 0053/68
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
product vervaardigd in en geëxporteerd uit de V.S.
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .