- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT07926672
Artificial Intelligence-Assisted Imaging for Diagnosis and Management of Focal Liver Lesions
A Prospective, Randomized Controlled Trial of Artificial Intelligence-Assisted Imaging for the Diagnosis and Clinical Management of Focal Liver Lesions
This study aims to evaluate the clinical value of artificial intelligence (AI)-assisted medical imaging in the diagnosis and management of focal liver lesions. Accurate diagnosis of focal liver lesions is important for selecting appropriate treatment strategies. However, distinguishing between different types of liver lesions can be challenging because of overlapping imaging features. AI-based imaging systems may help improve diagnostic accuracy and support clinical decision-making.
Studie Overzicht
Toestand
Conditie
Studietype
Inschrijving (Geschat)
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
Guangdong
-
Guangzhou, Guangdong, China
- Werving
- Sun Yat-sen University Cancer Center
-
Contact:
- Chao An
- Telefoonnummer: 20-87343088
- E-mail: anchao-1983@163.com
-
Guangzhou, Guangdong, China, 510080
- Werving
- The First Affiliated Hospital, Sun Yat-sen University
-
Contact:
- Zhenwei Peng
- Telefoonnummer: 020-87755766
- E-mail: pzhenw@mail.sysu.edu.cn
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- Patients aged 18-75 years.
- Patients undergoing clinically indicated liver computed tomography (CT) examinations.
Exclusion Criteria:
-Liver CT examinations that do not meet the predefined technical requirements or are nondiagnostic because of severe imaging artifacts.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Diagnostisch
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Dubbele
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: Artificial Intelligence-Assisted Imaging Group
|
An artificial intelligence-based imaging system will be used to assist the diagnosis of focal liver lesions through hierarchical classification. The system will evaluate lesion presence, distinguish benign from malignant lesions, and classify specific malignant and benign lesion types. For patients with independently confirmed hepatocellular carcinoma who undergo interventional therapy, an artificial intelligence-based prognostic model will additionally be evaluated for predicting overall survival and progression-free survival. |
|
Actieve vergelijker: Conventional Physician Imaging Group
|
Qualified physicians will independently interpret liver imaging examinations according to routine clinical practice without assistance from the study artificial intelligence system. The diagnostic assessment will include lesion detection, differentiation between benign and malignant lesions, and classification of lesion subtypes using established imaging criteria and clinical information. |
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Tijdsspanne |
|---|---|
|
Overall Diagnostic Accuracy of AI-Assisted Versus Conventional Physician Imaging Assessment
Tijdsspanne: At the index imaging assessment, with reference diagnosis established within 6 months after imaging.
|
At the index imaging assessment, with reference diagnosis established within 6 months after imaging.
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Percentage of Participants With Correct Detection of Focal Liver Lesions
Tijdsspanne: At the index computed tomography assessment, with the reference diagnosis established within 6 months after imaging.
|
Detection accuracy is defined as the percentage of participants correctly classified as having or not having focal liver lesions, based on the prespecified reference standard. Accuracy will be calculated as the number of correctly classified participants divided by the total number of participants with an evaluable reference diagnosis, multiplied by 100. Results will be reported separately for the artificial intelligence-assisted and standard diagnostic groups. Higher percentages indicate better diagnostic performance. |
At the index computed tomography assessment, with the reference diagnosis established within 6 months after imaging.
|
|
Percentage of Participants With Correct Benign Versus Malignant Classification of Focal Liver Lesions
Tijdsspanne: At the index computed tomography (CT) imaging assessment, with the reference diagnosis established within 6 months after imaging.
|
The outcome is the percentage of participants whose benign or malignant liver lesion classification matches the reference standard. Binary classification accuracy will be calculated as the number of correctly classified participants (true positives plus true negatives) divided by the total number of evaluable participants with a confirmed benign or malignant focal liver lesion, multiplied by 100. The seven-class diagnostic outputs will be grouped into benign and malignant categories according to a prespecified classification scheme. Results will be reported separately for the artificial intelligence (AI)-assisted and standard diagnostic groups. Higher percentages indicate better diagnostic accuracy. |
At the index computed tomography (CT) imaging assessment, with the reference diagnosis established within 6 months after imaging.
|
|
Percentage of Participants With Correct Classification of Benign Liver Lesion Subtypes
Tijdsspanne: At the index computed tomography imaging assessment, with the reference diagnosis established within 6 months after imaging.
|
The outcome is the percentage of participants with correctly classified benign liver lesion subtypes, based on the prespecified reference standard. The analysis will include participants with confirmed hepatic hemangioma or hepatic cyst. Subtype classification accuracy will be calculated as the number of participants whose predicted benign lesion subtype matches the reference diagnosis divided by the total number of evaluable participants with either of these two benign lesions, multiplied by 100. Predictions of an incorrect benign subtype, a malignant category, or no lesion will be counted as incorrect. Results will be reported separately for the artificial intelligence-assisted and standard diagnostic groups. Higher percentages indicate better diagnostic accuracy. |
At the index computed tomography imaging assessment, with the reference diagnosis established within 6 months after imaging.
|
|
Harrell's Concordance Index for Artificial Intelligence-Based Overall Survival Prediction in Patients With Hepatocellular Carcinoma
Tijdsspanne: From initiation of the index interventional treatment until death from any cause or last known follow-up, assessed up to 36 months.
|
The discriminative performance of the artificial intelligence (AI)-based model for predicting overall survival (OS) in patients with hepatocellular carcinoma (HCC) will be evaluated using Harrell's concordance index (C-index). Overall survival is defined as the time from initiation of the index interventional treatment to death from any cause. Patients who remain alive will be censored at their last known follow-up. The C-index measures the concordance between predicted survival risk and observed survival outcomes, accounting for censored observations. Values range from 0 to 1, with 0.5 indicating discrimination comparable to chance and 1 indicating perfect concordance. Higher values indicate better prognostic discrimination. |
From initiation of the index interventional treatment until death from any cause or last known follow-up, assessed up to 36 months.
|
|
Harrell's Concordance Index for Artificial Intelligence-Based Progression-Free Survival Prediction in Patients With Hepatocellular Carcinoma
Tijdsspanne: From initiation of the index interventional treatment until first documented disease progression or death from any cause, whichever occurs first, assessed up to 36 months.
|
The discriminative performance of the artificial intelligence (AI)-based model for predicting progression-free survival (PFS) in patients with hepatocellular carcinoma (HCC) will be evaluated using Harrell's concordance index (C-index). Progression-free survival is defined as the time from initiation of the index interventional treatment to the first documented disease progression or death from any cause, whichever occurs first. Disease progression will be determined according to the prespecified assessment criteria. Patients without progression or death will be censored at their last adequate disease assessment. The C-index measures the concordance between predicted progression risk and observed PFS outcomes, accounting for censored observations. Values range from 0 to 1, with 0.5 indicating discrimination comparable to chance and 1 indicating perfect concordance. Higher values indicate better prognostic discrimination. |
From initiation of the index interventional treatment until first documented disease progression or death from any cause, whichever occurs first, assessed up to 36 months.
|
Medewerkers en onderzoekers
Studie record data
Bestudeer belangrijke data
Studie start (Geschat)
Primaire voltooiing (Geschat)
Studie voltooiing (Geschat)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Andere studie-ID-nummers
- B2025-001-X02
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .